Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Line & Duct Burners

NP-RG AIRFLO®

NP/RG AIRFLO uses modular patterns matched to duct geometry for direct fresh-air heating.

NP/RG AIRFLO uses modular patterns matched to duct geometry for direct fresh-air heating. It burns the stated gaseous fuels without a separate combustion-air blower, with broad turndown and no burner moving parts. The source associates distributed heating with process efficiency; material and pattern selection remain specific to the installation.

Features & Benefits

Air Velocity Range
NP‑I/NP‑II ≈3000 fpm|NP‑III ≈4000 fpm|RG‑IV ≈1600-3200 fpm
Turndown Ratio
NP‑I 25:1|NP‑II 20:1|NP‑III 6:1|RG‑IV 20:1|staged configurations may exceed 50:1
Thermal Efficiency
Up to ~100% (direct‑fired) per bulletin statement of 100% thermal efficiency
Pressure Drop
NP‑I/NP‑II ≈0.6 in wc|NP‑III ≈1.0 in wc|RG‑IV ≈0.1-1.0 in wc (Process Air)
Natural Gas Pressure
NP‑I/NP‑III/RG‑IV ≈4.8-5.6 in wc|NP‑II ≈2.4-2.8 in wc
Model Name
NP‑I, NP‑II, NP‑III, RG‑IV
Maximum Capacity
NP-I/NP-II: 0.5 MBtu/h|NP-III - 1.0 Mbtu/h|RG-IV - 0.25 to 0.5 Mbtu/h
Material
Cast Iron Or Aluminum Body Options
Ignition Type
Spark ignitor, pilot and flame rod provisions; sequencing/control and safety shut‑off valves per system schematic
Fuel Type
Natural Gas; Propane and Propane‑air mixture (NP series); RG‑IV Natural Gas only
Flame Length
NP‑I/NP‑II ≈0.8-1 ft|NP‑III ≈2.3-2.6 ft|RG‑IV ≈1-1.1 ft
Dimensions
NP‑*-12 ≈12 x 7 x 6.5 in|RG‑IV‑12 ≈12 x 9 x 8.5 in (cast iron bodies) (Straight Sections)
  • No separate combustion-air blower is needed.
  • The burner has no moving parts to service.

Applications

  • Direct fresh-air heating
  • Makeup-air and space heating

Detailed capabilities

Direct fresh-air heating without a blower

NP/RG AIRFLO uses modular raw-gas sections in a pattern matched to the duct, so the process airstream provides combustion conditions. There are no burner moving parts or separate combustion-air blower. The source reports high thermal efficiency and broad turndown for direct fresh-air heating. Those statements should not be applied to a recirculated or oxygen-poor stream without the relevant burner design.

Manufacturer reference ↗

Features and benefits

  • No separate combustion-air blower is needed.
  • The burner has no moving parts to service.

Manufacturer reference ↗

Published application context

  • Direct fresh-air heating
  • Makeup-air and space heating

Manufacturer reference ↗

Specifications

Air & Combustion Air Specifications

Air Velocity Range
NP‑I/NP‑II ≈3000 fpm; NP‑III ≈4000 fpm; RG‑IV ≈1600-3200 fpm

Performance, Flow & Capacity

Turndown Ratio
NP‑I 25:1; NP‑II 20:1; NP‑III 6:1; RG‑IV 20:1; staged configurations may exceed 50:1

Temperature & Thermal Specifications

Thermal Efficiency
Up to ~100% (direct‑fired) per bulletin statement of 100% thermal efficiency

Pressure Specifications

Pressure Drop
NP‑I/NP‑II ≈0.6 in wc; NP‑III ≈1.0 in wc; RG‑IV ≈0.1-1.0 in wc (Process Air)
Natural Gas Pressure
NP‑I/NP‑III/RG‑IV ≈4.8-5.6 in wc; NP‑II ≈2.4-2.8 in wc

Overview

Model Name
NP‑I, NP‑II, NP‑III, RG‑IV

Processing & Performance Metrics

Maximum Capacity
NP-I/NP-II: 0.5 MBtu/h; NP-III - 1.0 Mbtu/h; RG-IV - 0.25 to 0.5 Mbtu/h

Material Specifications

Material
Cast Iron Or Aluminum Body Options

Ignition, Flame & Supervision Specifications

Ignition Type
Spark ignitor, pilot and flame rod provisions; sequencing/control and safety shut‑off valves per system schematic

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas; Propane and Propane‑air mixture (NP series); RG‑IV Natural Gas only

Burner/Flame‑Related Lengths

Flame Length
NP‑I/NP‑II ≈0.8-1 ft; NP‑III ≈2.3-2.6 ft; RG‑IV ≈1-1.1 ft

Dimensions & Weight

Dimensions
NP‑*-12 ≈12 x 7 x 6.5 in; RG‑IV‑12 ≈12 x 9 x 8.5 in (cast iron bodies) (Straight Sections)

Applications & Compatibility

Applications
Direct‑fired fresh air heating (make‑up air and process air), raw‑gas operation with profile plate velocity control
NP-RG AIRFLO® — manufacturer page values
ParameterPublished value / configuration
Air Velocity RangeNP‑I/NP‑II ≈3000 fpm; NP‑III ≈4000 fpm; RG‑IV ≈1600-3200 fpm
Turndown RatioNP‑I 25:1; NP‑II 20:1; NP‑III 6:1; RG‑IV 20:1; staged configurations may exceed 50:1
Thermal EfficiencyUp to ~100% (direct‑fired) per bulletin statement of 100% thermal efficiency
Pressure DropNP‑I/NP‑II ≈0.6 in wc; NP‑III ≈1.0 in wc; RG‑IV ≈0.1-1.0 in wc (Process Air)
Natural Gas PressureNP‑I/NP‑III/RG‑IV ≈4.8-5.6 in wc; NP‑II ≈2.4-2.8 in wc
Model NameNP‑I, NP‑II, NP‑III, RG‑IV
Maximum CapacityNP-I/NP-II: 0.5 MBtu/h; NP-III - 1.0 Mbtu/h; RG-IV - 0.25 to 0.5 Mbtu/h
MaterialCast Iron Or Aluminum Body Options
Ignition TypeSpark ignitor, pilot and flame rod provisions; sequencing/control and safety shut‑off valves per system schematic
Fuel TypeNatural Gas; Propane and Propane‑air mixture (NP series); RG‑IV Natural Gas only
Flame LengthNP‑I/NP‑II ≈0.8-1 ft; NP‑III ≈2.3-2.6 ft; RG‑IV ≈1-1.1 ft
DimensionsNP‑*-12 ≈12 x 7 x 6.5 in; RG‑IV‑12 ≈12 x 9 x 8.5 in (cast iron bodies) (Straight Sections)
ApplicationsDirect‑fired fresh air heating (make‑up air and process air), raw‑gas operation with profile plate velocity control

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
1015298NP-EC FR,SI END KIT MOD W/1"+Request quotation
101530636" NP-I REZNOR BRNRRequest quotation
101657842" NP-I REZNOR BRNRRequest quotation
101658048" NP-I REZNOR BRNRRequest quotation
101658760" NP-I REZNOR BRNRRequest quotation
101658966" NP-I REZNOR BRNRRequest quotation
101659272" NP-I REZNOR BRNRRequest quotation
10200846" NP-I-6P SECT W/PILT L/SIRequest quotation
1029210PILT KIT L/SIRequest quotation
10292111.25" END KIT MOD W/1" EXTD+Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/line-and-duct-burners/np-rg-airflo

Last source check: 2026-11-02

NP-RG AIRFLO Product Image · Manufacturer ownership retained; republication licence not independently confirmed

NP-RG AIRFLO Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

NP-RG AIRFLO Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry