COMBUSTIFUME supports direct firing in fume incineration and high-temperature air heating. Modular configurations adapt to duct geometry and heat release, including streams with the published low oxygen concentration or elevated inlet temperature. Primary combustion air can supplement oxygen-poor streams, and material variants match different process conditions.

Features & Benefits

Mixing Plate Materials
#310 Stainless Steel or Hastelloy‑X (by configuration)
Inlet Air Temperature
Up to 1050 deg F (566 deg C) approaching burner, Typically ≥ 500 deg F for raw gas firing
Design Considerations
Flexible connections for thermal growth|Profile plate ≥6 in all around|Uniform velocity across mixing plates|Use displacement areas to size opening
Modular Construction
Straight, tee, cross, back‑inlet, and “H” sections configurable into assemblies
Temperature Limits
Discharge up to 1500 deg F (816 deg C); see burner type table|Inlet up to 1700 deg F (927 deg C)
Oxygen Requirement
12-16% O₂ requires partial premixing|<12% not supported as raw gas|Raw gas firing typically requires ≥16% O₂
Flame Supervision
Flame rod acceptable ≤600 deg F|UV Scanner preferred and required >600 deg F inlet
Capacity Range
1,000,000 Btu/hr per lineal foot (raw gas firing) to 150,000 Btu/hr per lineal foot (raw gas systems)
Pressure Drop
Target ~1–2 in wc across burner + profile plate (tight profiling)
Ignition Type
Raw gas pilot (built-in or external) or direct ignition per application and local codes; pilot ~25,000 Btu/hr (INCINO-PAK)
Burner Design
Raw‑gas line burner for high‑temperature air streams
Model Name
COMBUSTIFUME® (e.g., CF4D, CF5 series variants)
Functions
Line burners for heating effluent/air streams in incineration and process systems
Fuel Type
Natural Gas or Propane (raw gas); partial premix with combustion air for 12 to 16% O₂ streams
Approvals
Maxon strongly endorses NFPA; block and bleed as required; two safety shut-off valves minimum
Material
Ductile Iron or Aluminum Bronze (by section designation)
  • Direct firing into the effluent avoids a separate indirect heating path.

Applications

  • Direct-fired fume incineration
  • Higher-temperature process-air heating

Detailed capabilities

Combustion in oxygen-reduced streams

COMBUSTIFUME can use a process stream with the stated reduced oxygen concentration or high inlet temperature, within its selected arrangement. Where oxygen is insufficient, primary combustion air can be added through the burner. Modular shapes and material varieties provide different heat-release and environmental capabilities. Direct firing in the effluent stream avoids an extra heat-transfer stage for fume incineration.

Manufacturer reference ↗

Features and benefits

  • Direct firing into the effluent avoids a separate indirect heating path.

Manufacturer reference ↗

Published application context

  • Direct-fired fume incineration
  • Higher-temperature process-air heating

Manufacturer reference ↗

Specifications

Material Specifications

Mixing Plate Materials
#310 Stainless Steel or Hastelloy‑X (by configuration)
Material
Ductile Iron or Aluminum Bronze (by section designation)

Air/Exhaust/Flue Gas Temperatures

Inlet Air Temperature
Up to 1050 deg F (566 deg C) approaching burner, Typically ≥ 500 deg F for raw gas firing

Overview

Design Considerations
Flexible connections for thermal growth; Profile plate ≥6 in all around; Uniform velocity across mixing plates; Use displacement areas to size opening
Model Name
COMBUSTIFUME® (e.g., CF4D, CF5 series variants)

Product Overview & Classification

Modular Construction
Straight, tee, cross, back‑inlet, and “H” sections configurable into assemblies

Temperature Control/Measurement

Temperature Limits
Discharge up to 1500 deg F (816 deg C); see burner type table; Inlet up to 1700 deg F (927 deg C)

Combustion, Mixing & Fuel Dynamics

Oxygen Requirement
12-16% O₂ requires partial premixing; <12% not supported as raw gas; Raw gas firing typically requires ≥16% O₂

Ignition, Flame & Supervision Specifications

Flame Supervision
Flame rod acceptable ≤600 deg F; UV Scanner preferred and required >600 deg F inlet
Ignition Type
Raw gas pilot (built-in or external) or direct ignition per application and local codes; pilot ~25,000 Btu/hr (INCINO-PAK)

Processing & Performance Metrics

Capacity Range
1,000,000 Btu/hr per lineal foot (raw gas firing) to 150,000 Btu/hr per lineal foot (raw gas systems)

Pressure Specifications

Pressure Drop
Target ~1–2 in wc across burner + profile plate (tight profiling)

Product Design & Configuration

Burner Design
Raw‑gas line burner for high‑temperature air streams

Applications & Compatibility

Applications
Heating of high‑temperature effluent and process air streams, including fume incineration; Thermal oxidizers, fume incinerators, high‑temperature process ducts, incineration systems

Control, Logic & Functional Behavior

Functions
Line burners for heating effluent/air streams in incineration and process systems

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas or Propane (raw gas); partial premix with combustion air for 12 to 16% O₂ streams

Standards & Certifications

Approvals
Maxon strongly endorses NFPA; block and bleed as required; two safety shut-off valves minimum
COMBUSTIFUME® — manufacturer page values
ParameterPublished value / configuration
Mixing Plate Materials#310 Stainless Steel or Hastelloy‑X (by configuration)
MaterialDuctile Iron or Aluminum Bronze (by section designation)
Inlet Air TemperatureUp to 1050 deg F (566 deg C) approaching burner, Typically ≥ 500 deg F for raw gas firing
Design ConsiderationsFlexible connections for thermal growth; Profile plate ≥6 in all around; Uniform velocity across mixing plates; Use displacement areas to size opening
Model NameCOMBUSTIFUME® (e.g., CF4D, CF5 series variants)
Modular ConstructionStraight, tee, cross, back‑inlet, and “H” sections configurable into assemblies
Temperature LimitsDischarge up to 1500 deg F (816 deg C); see burner type table; Inlet up to 1700 deg F (927 deg C)
Oxygen Requirement12-16% O₂ requires partial premixing; <12% not supported as raw gas; Raw gas firing typically requires ≥16% O₂
Flame SupervisionFlame rod acceptable ≤600 deg F; UV Scanner preferred and required >600 deg F inlet
Ignition TypeRaw gas pilot (built-in or external) or direct ignition per application and local codes; pilot ~25,000 Btu/hr (INCINO-PAK)
Capacity Range1,000,000 Btu/hr per lineal foot (raw gas firing) to 150,000 Btu/hr per lineal foot (raw gas systems)
Pressure DropTarget ~1–2 in wc across burner + profile plate (tight profiling)
Burner DesignRaw‑gas line burner for high‑temperature air streams
ApplicationsHeating of high‑temperature effluent and process air streams, including fume incineration; Thermal oxidizers, fume incinerators, high‑temperature process ducts, incineration systems
FunctionsLine burners for heating effluent/air streams in incineration and process systems
Fuel TypeNatural Gas or Propane (raw gas); partial premix with combustion air for 12 to 16% O₂ streams
ApprovalsMaxon strongly endorses NFPA; block and bleed as required; two safety shut-off valves minimum

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
1047387CF4-6-D-24 STR SECT ASYRequest quotation
1047388CF4-12-D-24 STR SECT ASYRequest quotation
1047389CF4-T-D-24 TEE SECT ASYRequest quotation
1047390CF4-X-D-24 CR SECT ASYRequest quotation
1047391CF4-12B-D-24 STR SECT ASYRequest quotation
1047392CF4-BX-D-24 CR SECT ASYRequest quotation
1047393CF4-BH-D-24 36B SECT ASYRequest quotation
1047394CF4-6-D-48 STR SECT ASYRequest quotation
1047395CF4-12-D-48 STR SECT ASYRequest quotation
1047396CF4-T-D-48 TEE SECT ASYRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/line-and-duct-burners/combustifume

Last source check: 2026-11-02

COMBUSTIFUME Product Image · Manufacturer ownership retained; republication licence not independently confirmed

COMBUSTIFUME Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry