Line & Duct Burners
COMBUSTIFUME®
COMBUSTIFUME supports direct firing in fume incineration and high-temperature air heating.
COMBUSTIFUME supports direct firing in fume incineration and high-temperature air heating. Modular configurations adapt to duct geometry and heat release, including streams with the published low oxygen concentration or elevated inlet temperature. Primary combustion air can supplement oxygen-poor streams, and material variants match different process conditions.
Features & Benefits
- Mixing Plate Materials
- #310 Stainless Steel or Hastelloy‑X (by configuration)
- Inlet Air Temperature
- Up to 1050 deg F (566 deg C) approaching burner, Typically ≥ 500 deg F for raw gas firing
- Design Considerations
- Flexible connections for thermal growth|Profile plate ≥6 in all around|Uniform velocity across mixing plates|Use displacement areas to size opening
- Modular Construction
- Straight, tee, cross, back‑inlet, and “H” sections configurable into assemblies
- Temperature Limits
- Discharge up to 1500 deg F (816 deg C); see burner type table|Inlet up to 1700 deg F (927 deg C)
- Oxygen Requirement
- 12-16% O₂ requires partial premixing|<12% not supported as raw gas|Raw gas firing typically requires ≥16% O₂
- Flame Supervision
- Flame rod acceptable ≤600 deg F|UV Scanner preferred and required >600 deg F inlet
- Capacity Range
- 1,000,000 Btu/hr per lineal foot (raw gas firing) to 150,000 Btu/hr per lineal foot (raw gas systems)
- Pressure Drop
- Target ~1–2 in wc across burner + profile plate (tight profiling)
- Ignition Type
- Raw gas pilot (built-in or external) or direct ignition per application and local codes; pilot ~25,000 Btu/hr (INCINO-PAK)
- Burner Design
- Raw‑gas line burner for high‑temperature air streams
- Model Name
- COMBUSTIFUME® (e.g., CF4D, CF5 series variants)
- Functions
- Line burners for heating effluent/air streams in incineration and process systems
- Fuel Type
- Natural Gas or Propane (raw gas); partial premix with combustion air for 12 to 16% O₂ streams
- Approvals
- Maxon strongly endorses NFPA; block and bleed as required; two safety shut-off valves minimum
- Material
- Ductile Iron or Aluminum Bronze (by section designation)
- Direct firing into the effluent avoids a separate indirect heating path.
Applications
- Direct-fired fume incineration
- Higher-temperature process-air heating
Detailed capabilities
Combustion in oxygen-reduced streams
COMBUSTIFUME can use a process stream with the stated reduced oxygen concentration or high inlet temperature, within its selected arrangement. Where oxygen is insufficient, primary combustion air can be added through the burner. Modular shapes and material varieties provide different heat-release and environmental capabilities. Direct firing in the effluent stream avoids an extra heat-transfer stage for fume incineration.
Features and benefits
- Direct firing into the effluent avoids a separate indirect heating path.
Published application context
- Direct-fired fume incineration
- Higher-temperature process-air heating
Material Specifications
- Mixing Plate Materials
- #310 Stainless Steel or Hastelloy‑X (by configuration)
- Material
- Ductile Iron or Aluminum Bronze (by section designation)
Air/Exhaust/Flue Gas Temperatures
- Inlet Air Temperature
- Up to 1050 deg F (566 deg C) approaching burner, Typically ≥ 500 deg F for raw gas firing
Overview
- Design Considerations
- Flexible connections for thermal growth; Profile plate ≥6 in all around; Uniform velocity across mixing plates; Use displacement areas to size opening
- Model Name
- COMBUSTIFUME® (e.g., CF4D, CF5 series variants)
Product Overview & Classification
- Modular Construction
- Straight, tee, cross, back‑inlet, and “H” sections configurable into assemblies
Temperature Control/Measurement
- Temperature Limits
- Discharge up to 1500 deg F (816 deg C); see burner type table; Inlet up to 1700 deg F (927 deg C)
Combustion, Mixing & Fuel Dynamics
- Oxygen Requirement
- 12-16% O₂ requires partial premixing; <12% not supported as raw gas; Raw gas firing typically requires ≥16% O₂
Ignition, Flame & Supervision Specifications
- Flame Supervision
- Flame rod acceptable ≤600 deg F; UV Scanner preferred and required >600 deg F inlet
- Ignition Type
- Raw gas pilot (built-in or external) or direct ignition per application and local codes; pilot ~25,000 Btu/hr (INCINO-PAK)
Processing & Performance Metrics
- Capacity Range
- 1,000,000 Btu/hr per lineal foot (raw gas firing) to 150,000 Btu/hr per lineal foot (raw gas systems)
Pressure Specifications
- Pressure Drop
- Target ~1–2 in wc across burner + profile plate (tight profiling)
Product Design & Configuration
- Burner Design
- Raw‑gas line burner for high‑temperature air streams
Applications & Compatibility
- Applications
- Heating of high‑temperature effluent and process air streams, including fume incineration; Thermal oxidizers, fume incinerators, high‑temperature process ducts, incineration systems
Control, Logic & Functional Behavior
- Functions
- Line burners for heating effluent/air streams in incineration and process systems
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas or Propane (raw gas); partial premix with combustion air for 12 to 16% O₂ streams
Standards & Certifications
- Approvals
- Maxon strongly endorses NFPA; block and bleed as required; two safety shut-off valves minimum
| Parameter | Published value / configuration |
|---|---|
| Mixing Plate Materials | #310 Stainless Steel or Hastelloy‑X (by configuration) |
| Material | Ductile Iron or Aluminum Bronze (by section designation) |
| Inlet Air Temperature | Up to 1050 deg F (566 deg C) approaching burner, Typically ≥ 500 deg F for raw gas firing |
| Design Considerations | Flexible connections for thermal growth; Profile plate ≥6 in all around; Uniform velocity across mixing plates; Use displacement areas to size opening |
| Model Name | COMBUSTIFUME® (e.g., CF4D, CF5 series variants) |
| Modular Construction | Straight, tee, cross, back‑inlet, and “H” sections configurable into assemblies |
| Temperature Limits | Discharge up to 1500 deg F (816 deg C); see burner type table; Inlet up to 1700 deg F (927 deg C) |
| Oxygen Requirement | 12-16% O₂ requires partial premixing; <12% not supported as raw gas; Raw gas firing typically requires ≥16% O₂ |
| Flame Supervision | Flame rod acceptable ≤600 deg F; UV Scanner preferred and required >600 deg F inlet |
| Ignition Type | Raw gas pilot (built-in or external) or direct ignition per application and local codes; pilot ~25,000 Btu/hr (INCINO-PAK) |
| Capacity Range | 1,000,000 Btu/hr per lineal foot (raw gas firing) to 150,000 Btu/hr per lineal foot (raw gas systems) |
| Pressure Drop | Target ~1–2 in wc across burner + profile plate (tight profiling) |
| Burner Design | Raw‑gas line burner for high‑temperature air streams |
| Applications | Heating of high‑temperature effluent and process air streams, including fume incineration; Thermal oxidizers, fume incinerators, high‑temperature process ducts, incineration systems |
| Functions | Line burners for heating effluent/air streams in incineration and process systems |
| Fuel Type | Natural Gas or Propane (raw gas); partial premix with combustion air for 12 to 16% O₂ streams |
| Approvals | Maxon strongly endorses NFPA; block and bleed as required; two safety shut-off valves minimum |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 1047387 | CF4-6-D-24 STR SECT ASY | Request quotation |
| 1047388 | CF4-12-D-24 STR SECT ASY | Request quotation |
| 1047389 | CF4-T-D-24 TEE SECT ASY | Request quotation |
| 1047390 | CF4-X-D-24 CR SECT ASY | Request quotation |
| 1047391 | CF4-12B-D-24 STR SECT ASY | Request quotation |
| 1047392 | CF4-BX-D-24 CR SECT ASY | Request quotation |
| 1047393 | CF4-BH-D-24 36B SECT ASY | Request quotation |
| 1047394 | CF4-6-D-48 STR SECT ASY | Request quotation |
| 1047395 | CF4-12-D-48 STR SECT ASY | Request quotation |
| 1047396 | CF4-T-D-48 TEE SECT ASY | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
COMBUSTIFUME Product Image · Manufacturer ownership retained; republication licence not independently confirmed
COMBUSTIFUME Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.