Line & Duct Burners
AirHeat v2
AirHeat v2 packages a line burner with combustion-air supply for ovens, dryers and incineration duties.
AirHeat v2 packages a line burner with combustion-air supply for ovens, dryers and incineration duties. Direct-spark ignition and pressure taps simplify commissioning, while the design avoids a low-fire bypass-air circuit. Aluminum construction and several mounting formats support duct, slot or sealed-flange installations, including blowerless recirculation configurations.
Features & Benefits
- Perpendicular Flow Velocity
- 500 to 1200 fpm (6 m/s)
- Combustion Air Blowers
- Integral combustion air blowers available (50 Hz and 60 Hz options)
- Optimum Duct Velocity
- 1000 to 4000 fpm (5 to 20 m/s)
- Visible Flame Length
- 43 in. (1100 mm), measured from combustor outlet (High Fire)
- Piping Configuration
- Right‑hand piping standard; left‑hand available
- Maximum Temperature
- 321 SS Wings - 1300 deg F (704 deg C), 330 SS Wings - 1500 deg F (815 deg C)
- Gas Inlet Pressure
- 8.7 in. wc (22 mbar) at gas inlet (Tap B)
- Mounting Options
- Sealed‑fired or slot‑fired duct mounting; continuous mounting; 6 in insertion options
- Input Capacity
- Max - 25,000 Btu/hr per lineal ft (24.5 kW/m)|Min - 1,000,000 Btu/hr per lineal ft (961 kW/m)
- Ignition Type
- Direct spark ignition; spark‑ignited pilot
- Duct Velocity
- 500 fpm (2.5 m/s), 6000 fpm (31 m/s) (Parallel Flow)
- Burner Design
- Line‑type air heating burner
- Fuel Type
- Natural Gas, Propane, Butane
- Eliminating low-fire bypass air reduces auxiliary piping.
- Pressure taps assist commissioning.
Applications
- Ovens
- Dryers
- Fume incinerators
Detailed capabilities
Changes in the second-generation package
AirHeat v2 supports direct-spark ignition and omits the low-fire bypass-air piping/check-valve circuit. Pressure taps separately expose gas, combustion air and chamber conditions during setup. Aluminum construction avoids the need for a special corrosion-resistant manifold in the described arrangement. Duct, slot and sealed-flange mounting options, including the specified insertion depth, are distinct choices rather than simultaneous mounting features.
Features and benefits
- Eliminating low-fire bypass air reduces auxiliary piping.
- Pressure taps assist commissioning.
Published application context
- Ovens
- Dryers
- Fume incinerators
Overview
- Models
- AH0050 through AH0400 (0.5 to 4 MMBtu/hr)
Processing & Performance Metrics
- Perpendicular Flow Velocity
- 500 to 1200 fpm (6 m/s)
Air & Combustion Air Specifications
- Combustion Air Blowers
- Integral combustion air blowers available (50 Hz and 60 Hz options)
Combustion Air, Blower & Emissions Specifications
- Optimum Duct Velocity
- 1000 to 4000 fpm (5 to 20 m/s)
- Duct Velocity
- 500 fpm (2.5 m/s), 6000 fpm (31 m/s) (Parallel Flow)
Burner/Flame‑Related Lengths
- Visible Flame Length
- 43 in. (1100 mm), measured from combustor outlet (High Fire)
Mechanical Design, Layout & Construction Options
- Piping Configuration
- Right‑hand piping standard; left‑hand available
Maximum/Minimum Temperature Limits
- Maximum Temperature
- 321 SS Wings - 1300 deg F (704 deg C), 330 SS Wings - 1500 deg F (815 deg C)
Pressure Specifications
- Gas Inlet Pressure
- 8.7 in. wc (22 mbar) at gas inlet (Tap B)
Installation & Mounting Specifications
- Mounting Options
- Sealed‑fired or slot‑fired duct mounting; continuous mounting; 6 in insertion options
Performance Specifications
- Input Capacity
- Max - 25,000 Btu/hr per lineal ft (24.5 kW/m); Min - 1,000,000 Btu/hr per lineal ft (961 kW/m)
Ignition, Flame & Supervision Specifications
- Ignition Type
- Direct spark ignition; spark‑ignited pilot
Product Design & Configuration
- Burner Design
- Line‑type air heating burner
Applications & Compatibility
- Applications
- Air heating for industrial process applications; Ovens, dryers, fume incinerators, and similar industrial equipment
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas, Propane, Butane
| Parameter | Published value / configuration |
|---|---|
| Models | AH0050 through AH0400 (0.5 to 4 MMBtu/hr) |
| Perpendicular Flow Velocity | 500 to 1200 fpm (6 m/s) |
| Combustion Air Blowers | Integral combustion air blowers available (50 Hz and 60 Hz options) |
| Optimum Duct Velocity | 1000 to 4000 fpm (5 to 20 m/s) |
| Duct Velocity | 500 fpm (2.5 m/s), 6000 fpm (31 m/s) (Parallel Flow) |
| Visible Flame Length | 43 in. (1100 mm), measured from combustor outlet (High Fire) |
| Piping Configuration | Right‑hand piping standard; left‑hand available |
| Maximum Temperature | 321 SS Wings - 1300 deg F (704 deg C), 330 SS Wings - 1500 deg F (815 deg C) |
| Gas Inlet Pressure | 8.7 in. wc (22 mbar) at gas inlet (Tap B) |
| Mounting Options | Sealed‑fired or slot‑fired duct mounting; continuous mounting; 6 in insertion options |
| Input Capacity | Max - 25,000 Btu/hr per lineal ft (24.5 kW/m); Min - 1,000,000 Btu/hr per lineal ft (961 kW/m) |
| Ignition Type | Direct spark ignition; spark‑ignited pilot |
| Burner Design | Line‑type air heating burner |
| Applications | Air heating for industrial process applications; Ovens, dryers, fume incinerators, and similar industrial equipment |
| Fuel Type | Natural Gas, Propane, Butane |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 10008245-10 | FLG,MTG,AHV2,6 " STNDFF,AH0100 BOT | Request quotation |
| 10008245-11 | FLG,MTG,AHV2,6 " STNDFF,AH0150 BOT | Request quotation |
| 10008245-12 | FLG,MTG,AHV2,6 " STNDFF,AH0200 BOT | Request quotation |
| 10008245-14 | FLG,MTG,AHV2,6 " STNDFF,AH0300 BOT | Request quotation |
| 10008245-2 | FLG,MTG,AHV2,6 " STNDFF,AH0100 TOP | Request quotation |
| 10008245-3 | FLG,MTG,AHV2,6 " STNDFF,AH0150 TOP | Request quotation |
| 10008245-4 | FLG,MTG,AHV2,6 " STNDFF,AH0200 TOP | Request quotation |
| 10008245-6 | FLG,MTG,AHV2,6 " STNDFF,AH0300 TOP | Request quotation |
| 10008245-9 | FLG,MTG,AHV2,6 " STNDFF,AH0050 BOT | Request quotation |
| 10008246 | GSKT,FLG,GAS INLT,6 " STNDFF,AHV2 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
AirHeat v2 Product Image · Manufacturer ownership retained; republication licence not independently confirmed
AirHeat v2 Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed
AirHeat v2 Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.