Line & Duct Burners
AirHeat v1
AirHeat v1 is a modular air-heating burner for ovens, dryers and related equipment.
AirHeat v1 is a modular air-heating burner for ovens, dryers and related equipment. An integral blower supplies combustion air independently of duct velocity, avoiding a surrounding profile plate within the specified range. Blowerless versions address recirculation, and natural-gas, propane and available butane configurations have their own selection requirements.
Features & Benefits
- Operating Velocity Range
- 250 to 6000 fpm (1.5 to 30 m/s) depending on configuration
- Recirculating Systems
- RAH, TAH, and CAH available for recirculating systems with remote blower
- Thermal Turndown
- Up to 40:1
- Product Variants
- AH, RAH (recirculating), AH‑O (open back), TAH (T‑section), CAH (cross‑section)
- Mounting Options
- Duct mounting or side‑plate mounting for simplified installation
- Heat Input Range
- Up to 1,000,000 Btu/hr per ft (293 kW)
- Burner Design
- Industry‑standard, modular line‑style burner
- Fuel Type
- Natural Gas or Propane, Butane versions available
- The blower stabilizes firing over the specified duct-velocity range without a profile plate.
Applications
- Ovens
- Dryers
- Fume incinerators
Detailed capabilities
Independent combustion air and the duct stream
The packaged blower supplies the air volume and pressure needed by the flame, allowing operation through the specified process-velocity range without a profile plate around the burner. No combustion oxygen is required from the process airstream. This distinguishes the arrangement from raw-gas burners that depend on the duct stream for combustion. A version without the blower is described specifically for recirculating-air use.
Fuel and firing-range qualifications
Natural gas and propane are directly listed, with butane versions available. The page gives up to 40:1 gas turndown, low excess air at high fire and the stated maximum input for this burner arrangement. These figures belong to AirHeat v1 and its selected configuration. Integral-blower steel-case construction and modular sections support ovens, dryers and fume incinerators with limited routine maintenance.
Features and benefits
- The blower stabilizes firing over the specified duct-velocity range without a profile plate.
Published application context
- Ovens
- Dryers
- Fume incinerators
Processing & Performance Metrics
- Operating Velocity Range
- 250 to 6000 fpm (1.5 to 30 m/s) depending on configuration
Actuation, Valve & Motion Control Specifications
- Recirculating Systems
- RAH, TAH, and CAH available for recirculating systems with remote blower
Temperature & Thermal Specifications
- Thermal Turndown
- Up to 40:1
Product Overview & Classification
- Product Variants
- AH, RAH (recirculating), AH‑O (open back), TAH (T‑section), CAH (cross‑section)
Installation & Mounting Specifications
- Mounting Options
- Duct mounting or side‑plate mounting for simplified installation
Performance, Flow & Capacity
- Heat Input Range
- Up to 1,000,000 Btu/hr per ft (293 kW)
Product Design & Configuration
- Burner Design
- Industry‑standard, modular line‑style burner
Applications & Compatibility
- Applications
- Generation of clean, hot air for industrial processes; Ovens, dryers, fume incinerators, and similar industrial equipment
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas or Propane, Butane versions available
| Parameter | Published value / configuration |
|---|---|
| Operating Velocity Range | 250 to 6000 fpm (1.5 to 30 m/s) depending on configuration |
| Recirculating Systems | RAH, TAH, and CAH available for recirculating systems with remote blower |
| Thermal Turndown | Up to 40:1 |
| Product Variants | AH, RAH (recirculating), AH‑O (open back), TAH (T‑section), CAH (cross‑section) |
| Mounting Options | Duct mounting or side‑plate mounting for simplified installation |
| Heat Input Range | Up to 1,000,000 Btu/hr per ft (293 kW) |
| Burner Design | Industry‑standard, modular line‑style burner |
| Applications | Generation of clean, hot air for industrial processes; Ovens, dryers, fume incinerators, and similar industrial equipment |
| Fuel Type | Natural Gas or Propane, Butane versions available |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 00.0013047.99 | SI,M14X1,25,M14X1.25 | Request quotation |
| 00.3011990.13 | WING,AIR,STR,AH,AH,AISI310 1.4841,TOPHOL | Request quotation |
| 00.3012986.13 | WING,AIR,TEE,CR,AH,AISI310,W TOP HOLES,T | Request quotation |
| 00.3041990.00 | WING,AIR,STR,AH,AH,AISI321 1.4541,WO TOP | Request quotation |
| 00.3041990.03 | WING,AIR,STR,AH,AH,AISI310 1.4841,WO TOP | Request quotation |
| 00.4100030.05 | Shld Flm AH Inlt Plt Slot Ppst 185 mm | Request quotation |
| 00.4100030.06 | SHLD,FLM,AH,INLT PLT,SLOT PPST,160 MM | Request quotation |
| 00.4100071.16 | 640 TAH Complete Position I | Request quotation |
| 00.4100221.02 | FLG,INLT,AH BURNERS,UK00106 | Request quotation |
| 00.4100222.01 | PLT,INLT,AH,H 268 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
AirHeat v1 Product Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.