AirHeat v1 is a modular air-heating burner for ovens, dryers and related equipment.

AirHeat v1 is a modular air-heating burner for ovens, dryers and related equipment. An integral blower supplies combustion air independently of duct velocity, avoiding a surrounding profile plate within the specified range. Blowerless versions address recirculation, and natural-gas, propane and available butane configurations have their own selection requirements.

Features & Benefits

Operating Velocity Range
250 to 6000 fpm (1.5 to 30 m/s) depending on configuration
Recirculating Systems
RAH, TAH, and CAH available for recirculating systems with remote blower
Thermal Turndown
Up to 40:1
Product Variants
AH, RAH (recirculating), AH‑O (open back), TAH (T‑section), CAH (cross‑section)
Mounting Options
Duct mounting or side‑plate mounting for simplified installation
Heat Input Range
Up to 1,000,000 Btu/hr per ft (293 kW)
Burner Design
Industry‑standard, modular line‑style burner
Fuel Type
Natural Gas or Propane, Butane versions available
  • The blower stabilizes firing over the specified duct-velocity range without a profile plate.

Applications

  • Ovens
  • Dryers
  • Fume incinerators

Detailed capabilities

Independent combustion air and the duct stream

The packaged blower supplies the air volume and pressure needed by the flame, allowing operation through the specified process-velocity range without a profile plate around the burner. No combustion oxygen is required from the process airstream. This distinguishes the arrangement from raw-gas burners that depend on the duct stream for combustion. A version without the blower is described specifically for recirculating-air use.

Manufacturer reference ↗

Fuel and firing-range qualifications

Natural gas and propane are directly listed, with butane versions available. The page gives up to 40:1 gas turndown, low excess air at high fire and the stated maximum input for this burner arrangement. These figures belong to AirHeat v1 and its selected configuration. Integral-blower steel-case construction and modular sections support ovens, dryers and fume incinerators with limited routine maintenance.

Manufacturer reference ↗

Features and benefits

  • The blower stabilizes firing over the specified duct-velocity range without a profile plate.

Manufacturer reference ↗

Published application context

  • Ovens
  • Dryers
  • Fume incinerators

Manufacturer reference ↗

Specifications

Processing & Performance Metrics

Operating Velocity Range
250 to 6000 fpm (1.5 to 30 m/s) depending on configuration

Actuation, Valve & Motion Control Specifications

Recirculating Systems
RAH, TAH, and CAH available for recirculating systems with remote blower

Temperature & Thermal Specifications

Thermal Turndown
Up to 40:1

Product Overview & Classification

Product Variants
AH, RAH (recirculating), AH‑O (open back), TAH (T‑section), CAH (cross‑section)

Installation & Mounting Specifications

Mounting Options
Duct mounting or side‑plate mounting for simplified installation

Performance, Flow & Capacity

Heat Input Range
Up to 1,000,000 Btu/hr per ft (293 kW)

Product Design & Configuration

Burner Design
Industry‑standard, modular line‑style burner

Applications & Compatibility

Applications
Generation of clean, hot air for industrial processes; Ovens, dryers, fume incinerators, and similar industrial equipment

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas or Propane, Butane versions available
AirHeat v1 — manufacturer page values
ParameterPublished value / configuration
Operating Velocity Range250 to 6000 fpm (1.5 to 30 m/s) depending on configuration
Recirculating SystemsRAH, TAH, and CAH available for recirculating systems with remote blower
Thermal TurndownUp to 40:1
Product VariantsAH, RAH (recirculating), AH‑O (open back), TAH (T‑section), CAH (cross‑section)
Mounting OptionsDuct mounting or side‑plate mounting for simplified installation
Heat Input RangeUp to 1,000,000 Btu/hr per ft (293 kW)
Burner DesignIndustry‑standard, modular line‑style burner
ApplicationsGeneration of clean, hot air for industrial processes; Ovens, dryers, fume incinerators, and similar industrial equipment
Fuel TypeNatural Gas or Propane, Butane versions available

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
00.0013047.99SI,M14X1,25,M14X1.25Request quotation
00.3011990.13WING,AIR,STR,AH,AH,AISI310 1.4841,TOPHOLRequest quotation
00.3012986.13WING,AIR,TEE,CR,AH,AISI310,W TOP HOLES,TRequest quotation
00.3041990.00WING,AIR,STR,AH,AH,AISI321 1.4541,WO TOPRequest quotation
00.3041990.03WING,AIR,STR,AH,AH,AISI310 1.4841,WO TOPRequest quotation
00.4100030.05Shld Flm AH Inlt Plt Slot Ppst 185 mmRequest quotation
00.4100030.06SHLD,FLM,AH,INLT PLT,SLOT PPST,160 MMRequest quotation
00.4100071.16640 TAH Complete Position IRequest quotation
00.4100221.02FLG,INLT,AH BURNERS,UK00106Request quotation
00.4100222.01PLT,INLT,AH,H 268Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/line-and-duct-burners/airheat-v1