Line & Duct Burners
APX Burner Line Burner
APX uses a single aluminum extrusion for its fuel and air manifolds, reducing body joints in a nozzle-mix line burner.
APX uses a single aluminum extrusion for its fuel and air manifolds, reducing body joints in a nozzle-mix line burner. Straight, H-shaped and custom-grid arrangements address fresh or low-temperature recirculated air. The source distinguishes maximum straight-burner length from packaged-unit length, with low-pressure natural gas, propane or butane specified.
Features & Benefits
- Installation Orientation
- Horizontal or vertical firing (upward or downward)
- Mixing Plate Materials
- Stainless Steel
- Service Requirements
- Annual inspection recommended; visual flame and piping checks
- Typical Excess Air
- Clean fresh combustion air, 21% O2; max 120°F; constant or modulated airflow
- Process Conditions
- In-duct back pressure -40 to +40 in wc|Min process air velocity 6 ft/s|Slide-in ±12 in wc|Wall-mount suction/balanced
- CO/NOx Performance
- Low CO and NOx over full turndown (application‑dependent)
- Mounting Options
- Packaged or external blower|Slot-mounted or continuous flange|Wall-mounted (external), in-duct, slide-in unit
- Maximum Capacity
- Up to 1.0 MBtu/h per ft (recirculating air)|Up to 1.36 MBtu/h per ft (fresh air)
- Turndown Ratio
- Up to 30:1 (recirculating air)|Up to 40:1 (fresh air)
- Ignition Type
- Pilot ignition or direct ignition (configuration‑dependent)
- Flame Length
- Recirculating: 7-10 ft (application dependent)|Typical fresh air: 3-5 ft
- Model Name
- APX Burner Line Burner
- Functions
- Nozzle-mix line burner for fresh or low-temperature recirculating air heating applications
- Fuel Type
- Natural Gas, Propane, Butane; LPG capable with proper controls
- Material
- Single-Piece Aluminum Extrusion Air/Gas Body
- A jointless extrusion reduces potential body leakage points.
Applications
- Fresh-air heating
- Low-temperature recirculated-air heating
Detailed capabilities
Jointless manifolds and modular geometry
APX shares a single aluminum extrusion between its gas and air passages, reducing manifold joints and potential leaks. Stainless mixing plates complete the flame section. Straight, H-shaped and engineered-grid patterns fit the duct, with separate maximum lengths for straight designs and supplied packages. The burner supplies nozzle-mix combustion independently of varying process airflow and is limited to the specified low-pressure gas fuels.
Features and benefits
- A jointless extrusion reduces potential body leakage points.
Published application context
- Fresh-air heating
- Low-temperature recirculated-air heating
Installation & Mounting Specifications
- Installation Orientation
- Horizontal or vertical firing (upward or downward)
- Mounting Options
- Packaged or external blower; Slot-mounted or continuous flange; Wall-mounted (external), in-duct, slide-in unit
Material Specifications
- Mixing Plate Materials
- Stainless Steel
- Material
- Single-Piece Aluminum Extrusion Air/Gas Body
Ignition, Flame & Supervision Specifications
- Service Requirements
- Annual inspection recommended; visual flame and piping checks
- Ignition Type
- Pilot ignition or direct ignition (configuration‑dependent)
Combustion Air, Blower & Emissions Specifications
- Typical Excess Air
- Clean fresh combustion air, 21% O2; max 120°F; constant or modulated airflow
Processing & Performance Metrics
- Process Conditions
- In-duct back pressure -40 to +40 in wc; Min process air velocity 6 ft/s; Slide-in ±12 in wc; Wall-mount suction/balanced
- CO/NOx Performance
- Low CO and NOx over full turndown (application‑dependent)
- Maximum Capacity
- Up to 1.0 MBtu/h per ft (recirculating air); Up to 1.36 MBtu/h per ft (fresh air)
Performance, Flow & Capacity
- Turndown Ratio
- Up to 30:1 (recirculating air); Up to 40:1 (fresh air)
Burner/Flame‑Related Lengths
- Flame Length
- Recirculating: 7-10 ft (application dependent); Typical fresh air: 3-5 ft
Applications & Compatibility
- Applications
- Fresh air and low‑temperature recirculating air heating; Make‑up air systems, spray booths, ovens, dryers, paper, food, gypsum, paint shops
Overview
- Model Name
- APX Burner Line Burner
Control, Logic & Functional Behavior
- Functions
- Nozzle-mix line burner for fresh or low-temperature recirculating air heating applications
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas, Propane, Butane; LPG capable with proper controls
| Parameter | Published value / configuration |
|---|---|
| Installation Orientation | Horizontal or vertical firing (upward or downward) |
| Mounting Options | Packaged or external blower; Slot-mounted or continuous flange; Wall-mounted (external), in-duct, slide-in unit |
| Mixing Plate Materials | Stainless Steel |
| Material | Single-Piece Aluminum Extrusion Air/Gas Body |
| Service Requirements | Annual inspection recommended; visual flame and piping checks |
| Ignition Type | Pilot ignition or direct ignition (configuration‑dependent) |
| Typical Excess Air | Clean fresh combustion air, 21% O2; max 120°F; constant or modulated airflow |
| Process Conditions | In-duct back pressure -40 to +40 in wc; Min process air velocity 6 ft/s; Slide-in ±12 in wc; Wall-mount suction/balanced |
| CO/NOx Performance | Low CO and NOx over full turndown (application‑dependent) |
| Maximum Capacity | Up to 1.0 MBtu/h per ft (recirculating air); Up to 1.36 MBtu/h per ft (fresh air) |
| Turndown Ratio | Up to 30:1 (recirculating air); Up to 40:1 (fresh air) |
| Flame Length | Recirculating: 7-10 ft (application dependent); Typical fresh air: 3-5 ft |
| Applications | Fresh air and low‑temperature recirculating air heating; Make‑up air systems, spray booths, ovens, dryers, paper, food, gypsum, paint shops |
| Model Name | APX Burner Line Burner |
| Functions | Nozzle-mix line burner for fresh or low-temperature recirculating air heating applications |
| Fuel Type | Natural Gas, Propane, Butane; LPG capable with proper controls |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 0050APX | .5' APX LINEBURNER | Request quotation |
| 0100APX | 1' APX LINEBURNER | Request quotation |
| 0150APX | 1.5 FT APX Burner | Request quotation |
| 0200APX | 2' APX LINEBURNER | Request quotation |
| 0250APX | 2.5' APX LINEBURNER | Request quotation |
| 0300APX | 3' APX LINEBURNER | Request quotation |
| 0350APX | 3.5' APX LINEBURNER | Request quotation |
| 0350APXGAB | SPL 3.5' GA BRAUN APX LINEBURNER | Request quotation |
| 0400APX | 4' APX LINEBURNER | Request quotation |
| 0500APX | 5' APX LINEBURNER | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
APX Burner Line Burner Product Image · Manufacturer ownership retained; republication licence not independently confirmed
APX Burner Line Burner Product Image 3 · Manufacturer ownership retained; republication licence not independently confirmed
APX Burner Line Burner Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed
APX Burner Line Burner Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.