Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Line & Duct Burners

CROSSFIRE®

CROSSFIRE is a modular nozzle-mix burner for fresh and recirculated industrial air heating.

CROSSFIRE is a modular nozzle-mix burner for fresh and recirculated industrial air heating. Straight, grid and cartridge sections distribute heat across the duct. The manufacturer describes moisture-rich, low-oxygen and inert streams, with application-qualified emission figures; SMARTFIRE controls are offered to coordinate combustion efficiency and emissions.

Features & Benefits

Air Stream Conditions
Suitable for high‑moisture, low‑O₂, and highly inert air streams
Process Air Velocity
Parallel velocities up to 4000 fpm; cross velocities up to 3000 fpm
Control System Type
MICRO-RATIO® valve for air and fuel; manual start-up adjustments then reconnect for automatic control
Flame Supervision
UV Scanner recommended; use magnifying lens when Scanner tube length > 24 in
Mounting Options
Provide independent supports for burner and gas piping; use flexible connections to allow for thermal expansion; avoid external loads on inlets
CO/NOx Emissions
25 ppm NOx at 3 % O₂ achievable (application‑dependent)|250 ppm CO at 3 % O₂ achievable (application‑dependent)
Firing Capacity
Up to 2,500,000 Btu/hr per foot (per CROSSFIRE Fuel/Air Settings reference)
Turndown Ratio
Up to 25:1
Mixing Concept
Homogeneous fuel/air jet impingement producing high excess air combustion
Ignition Type
Pilot/ignition takes combustion air from upstream of the MICRO-RATIO® valve; spark ignitor fed through duct wall; pilot bleed air to prevent soot; pilot to be interrupted after main flame is established
Burner Design
Nozzle‑mixing line burner
Functions
Line burner requiring external blower; gas and air are piped separately into the burner assembly
Fuel Type
Low‑pressure natural gas
Material
Stainless‑Steel Housings and Nickel‑Plated Bodies
  • Modular sections distribute heat across the duct.

Applications

  • Fresh and recirculated process-air heating

Detailed capabilities

Modular burner patterns and process conditions

CROSSFIRE sections can form straight, grid or insert-cartridge arrangements to spread heat across a duct. The nozzle-mixing construction supplies combustion air to the flame rather than assuming every process stream has the same composition. Honeywell describes use in moist, low-oxygen and highly inert streams, with distinct parallel and crossflow velocity limits. Actual stream suitability remains an application-specific selection.

Manufacturer reference ↗

Combustion performance and coordinated control

The family offers high heat release per burner length and up to 25:1 turndown. The cited NOx/CO values are stated as achievable, referenced to 3% oxygen, rather than guaranteed for any installation. SMARTFIRE can be combined with the burner to coordinate ratio control and operating conditions. Stainless housings and nickel-plated body versions provide construction alternatives for the selected process environment.

Manufacturer reference ↗

Features and benefits

  • Modular sections distribute heat across the duct.

Manufacturer reference ↗

Published application context

  • Fresh and recirculated process-air heating

Manufacturer reference ↗

Specifications

Air & Combustion Air Specifications

Air Stream Conditions
Suitable for high‑moisture, low‑O₂, and highly inert air streams
Process Air Velocity
Parallel velocities up to 4000 fpm; cross velocities up to 3000 fpm

Control, Logic & Functional Behavior

Control System Type
MICRO-RATIO® valve for air and fuel; manual start-up adjustments then reconnect for automatic control
Functions
Line burner requiring external blower; gas and air are piped separately into the burner assembly

Ignition, Flame & Supervision Specifications

Flame Supervision
UV Scanner recommended; use magnifying lens when Scanner tube length > 24 in
Ignition Type
Pilot/ignition takes combustion air from upstream of the MICRO-RATIO® valve; spark ignitor fed through duct wall; pilot bleed air to prevent soot; pilot to be interrupted after main flame is established

Installation & Mounting Specifications

Mounting Options
Provide independent supports for burner and gas piping; use flexible connections to allow for thermal expansion; avoid external loads on inlets

Processing & Performance Metrics

CO/NOx Emissions
25 ppm NOx at 3 % O₂ achievable (application‑dependent); 250 ppm CO at 3 % O₂ achievable (application‑dependent)

Performance Specifications

Firing Capacity
Up to 2,500,000 Btu/hr per foot (per CROSSFIRE Fuel/Air Settings reference)

Performance, Flow & Capacity

Turndown Ratio
Up to 25:1

Combustion, Mixing & Fuel Dynamics

Mixing Concept
Homogeneous fuel/air jet impingement producing high excess air combustion

Product Design & Configuration

Burner Design
Nozzle‑mixing line burner

Applications & Compatibility

Applications
Induct firing in process heating systems (fresh or recirculated air)

Fuel, Gas & Media Specifications

Fuel Type
Low‑pressure natural gas

Material Specifications

Material
Stainless‑Steel Housings and Nickel‑Plated Bodies
CROSSFIRE® — manufacturer page values
ParameterPublished value / configuration
Air Stream ConditionsSuitable for high‑moisture, low‑O₂, and highly inert air streams
Process Air VelocityParallel velocities up to 4000 fpm; cross velocities up to 3000 fpm
Control System TypeMICRO-RATIO® valve for air and fuel; manual start-up adjustments then reconnect for automatic control
FunctionsLine burner requiring external blower; gas and air are piped separately into the burner assembly
Flame SupervisionUV Scanner recommended; use magnifying lens when Scanner tube length > 24 in
Ignition TypePilot/ignition takes combustion air from upstream of the MICRO-RATIO® valve; spark ignitor fed through duct wall; pilot bleed air to prevent soot; pilot to be interrupted after main flame is established
Mounting OptionsProvide independent supports for burner and gas piping; use flexible connections to allow for thermal expansion; avoid external loads on inlets
CO/NOx Emissions25 ppm NOx at 3 % O₂ achievable (application‑dependent); 250 ppm CO at 3 % O₂ achievable (application‑dependent)
Firing CapacityUp to 2,500,000 Btu/hr per foot (per CROSSFIRE Fuel/Air Settings reference)
Turndown RatioUp to 25:1
Mixing ConceptHomogeneous fuel/air jet impingement producing high excess air combustion
Burner DesignNozzle‑mixing line burner
ApplicationsInduct firing in process heating systems (fresh or recirculated air)
Fuel TypeLow‑pressure natural gas
MaterialStainless‑Steel Housings and Nickel‑Plated Bodies

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
0.5EIXFSTR6" End Inlet Crossfire StraightRequest quotation
1.5EIXFSTR1.5' End Inlet Crossfire StraightRequest quotation
1043403END BRKTRequest quotation
1044853PLTD PILT END PLTRequest quotation
1044879PILT AIR END CAPRequest quotation
1044880SS PILT AIR END CAPRequest quotation
1045009CROSSFIRE EXTL CVR PLTRequest quotation
1045010CROSSFIRE EXTL MTG PLTRequest quotation
10450543",4" ADPT FLGRequest quotation
10450553",4" SS ADPT FLGRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/line-and-duct-burners/crossfire

Last source check: 2026-11-02

CROSSFIRE Product Image · Manufacturer ownership retained; republication licence not independently confirmed

CROSSFIRE Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

CROSSFIRE Product Image 3 · Manufacturer ownership retained; republication licence not independently confirmed

CROSSFIRE Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry