Line & Duct Burners
Minnox
Minnox uses excess-air premixing and a recirculating flame to reduce both NOx and CO in direct process-air heating.
Minnox uses excess-air premixing and a recirculating flame to reduce both NOx and CO in direct process-air heating. Custom systems typically package burner, mixer and manifold into a duct section or insertion plate. Published applications include food, malt, coatings, wood and paper; emissions figures use the stated oxygen correction.
Features & Benefits
- Process Air Differential Pressure
- At 10 m/s: ≈0.5 mbar (≈0.2 in wc)|At 20 m/s: ≈2.0 mbar (≈0.8 in wc) (estimated)
- Combustion Air Temperature Range
- ≤ 40 deg C (104 deg F)
- Proportionator Gas Pressure
- Max 300 mbar (120 in wc)|Min 100 mbar (40 in wc)
- Process Outlet Temperature
- ≤ 500 deg C (930 deg F)
- Process Inlet Temperature
- ≤ 300 deg C (570 deg F)
- Process Pressure Limits
- Negative: ≤ 6 mbar (2.4 in wc); Positive: ≤ 10 mbar (4 in wc)
- Combustion Air Pressure
- 48 mbar at mixer inlet (19.3 in wc), neutral chamber pressure
- Combustion Air Volume
- 205 Nm³/h per 135 kW (120 scfm per 460,000 Btu/h)
- Visible Flame Length
- 300 mm (12 in) from whirl plate; protected by 400 mm (16 in) combustion chamber
- Process Air Velocity
- Max ≈20 m/s (≈3900 ft/min)|Min ≈2 m/s (≈390 ft/min)|Recommended ≈12 m/s (≈2400 ft/min)
- Pilot Gas Pressure
- Max 28 mbar (11 in wc)|Min 16 mbar (6.5 in wc)
- Burner Start Input
- 20% of nominal input
- Mounting Options
- Vertical (up/down), Horizontal (left/right), or Slot Firing
- Heat Input Range
- Cross: 675 kW (2,305,000 Btu/h) (per section)|Straight: 135 kW (460,000 Btu/h)|T-Section: 540 kW (1,844,000 Btu/h)
- Flame Detection
- UV Scanner
- Turndown Ratio
- 10:1
- Ignition Type
- Spark‑ignited integral pilot, nozzle‑mix type
- Burner Design
- Ultra‑Low Emissions (ULE) nozzle‑mix burner with integrated mixer
- Pilot Input
- ≈15 kW (≈51,000 Btu/h)
- Pilot Type
- Integral, nozzle‑mixing, spark‑ignited; interrupted pilot
- Model Name
- Minnox ULE, V1
- Fuel Type
- Natural Gas (H); Propane (<10% unsaturated); Butane (<10% unsaturated)
- Emissions
- NOx < 5 ppm; CO < 30 ppm; HCHO < 0.17 ppm (not guaranteed; process‑dependent) (at 3% O₂, estimated)
- Low-emission direct heating avoids the efficiency penalty of a separate indirect heater.
Applications
- Food processing
- Malt processing
- Automotive finishing
- Lumber processing
- Paper processing
Detailed capabilities
Premixed excess-air combustion
Minnox combines a lean premixed fuel/air stream with a recirculating flame pattern. Excess air lowers the flame temperature, while recirculation addresses CO, allowing direct process heating with very low reported emissions. The published NOx and CO levels use a 3% oxygen reference. They should be treated as manufacturer performance statements for the described system rather than a blanket compliance determination for every jurisdiction or installation.
Custom process integration
Minnox systems are engineered for the production duty and installation. Typical supply combines burner, mixer and manifold in a duct section or on a side plate for an existing duct. Published uses include food products, malt, automotive coatings, lumber and paper. The source associates the clean direct-heating approach with avoiding product discoloration or taste contamination, but the complete application still depends on the configured process system.
Features and benefits
- Low-emission direct heating avoids the efficiency penalty of a separate indirect heater.
Published application context
- Food processing
- Malt processing
- Automotive finishing
- Lumber processing
- Paper processing
Pressure Specifications
- Process Air Differential Pressure
- At 10 m/s: ≈0.5 mbar (≈0.2 in wc); At 20 m/s: ≈2.0 mbar (≈0.8 in wc) (estimated)
- Proportionator Gas Pressure
- Max 300 mbar (120 in wc); Min 100 mbar (40 in wc)
- Process Pressure Limits
- Negative: ≤ 6 mbar (2.4 in wc); Positive: ≤ 10 mbar (4 in wc)
- Combustion Air Pressure
- 48 mbar at mixer inlet (19.3 in wc), neutral chamber pressure
- Pilot Gas Pressure
- Max 28 mbar (11 in wc); Min 16 mbar (6.5 in wc)
Combustion/Furnace/Chamber Temperatures
- Combustion Air Temperature Range
- ≤ 40 deg C (104 deg F)
Operating/Process Temperature Ranges
- Process Outlet Temperature
- ≤ 500 deg C (930 deg F)
- Process Inlet Temperature
- ≤ 300 deg C (570 deg F)
Air & Combustion Air Specifications
- Combustion Air Volume
- 205 Nm³/h per 135 kW (120 scfm per 460,000 Btu/h)
- Process Air Velocity
- Max ≈20 m/s (≈3900 ft/min); Min ≈2 m/s (≈390 ft/min); Recommended ≈12 m/s (≈2400 ft/min)
Burner/Flame‑Related Lengths
- Visible Flame Length
- 300 mm (12 in) from whirl plate; protected by 400 mm (16 in) combustion chamber
Control, Logic & System Behavior
- Burner Start Input
- 20% of nominal input
Installation & Mounting Specifications
- Mounting Options
- Vertical (up/down), Horizontal (left/right), or Slot Firing
Performance, Flow & Capacity
- Heat Input Range
- Cross: 675 kW (2,305,000 Btu/h) (per section); Straight: 135 kW (460,000 Btu/h); T-Section: 540 kW (1,844,000 Btu/h)
- Turndown Ratio
- 10:1
Ignition, Flame & Supervision Specifications
- Flame Detection
- UV Scanner
- Ignition Type
- Spark‑ignited integral pilot, nozzle‑mix type
Product Design & Configuration
- Burner Design
- Ultra‑Low Emissions (ULE) nozzle‑mix burner with integrated mixer
Applications & Compatibility
- Applications
- Direct‑fired process air heating in ducts
Combustion, Fuel & Mixing Sub‑Systems
- Pilot Input
- ≈15 kW (≈51,000 Btu/h)
- Pilot Type
- Integral, nozzle‑mixing, spark‑ignited; interrupted pilot
Overview
- Model Name
- Minnox ULE, V1
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas (H); Propane (<10% unsaturated); Butane (<10% unsaturated)
Processing & Performance Metrics
- Emissions
- NOx < 5 ppm; CO < 30 ppm; HCHO < 0.17 ppm (not guaranteed; process‑dependent) (at 3% O₂, estimated)
| Parameter | Published value / configuration |
|---|---|
| Process Air Differential Pressure | At 10 m/s: ≈0.5 mbar (≈0.2 in wc); At 20 m/s: ≈2.0 mbar (≈0.8 in wc) (estimated) |
| Proportionator Gas Pressure | Max 300 mbar (120 in wc); Min 100 mbar (40 in wc) |
| Process Pressure Limits | Negative: ≤ 6 mbar (2.4 in wc); Positive: ≤ 10 mbar (4 in wc) |
| Combustion Air Pressure | 48 mbar at mixer inlet (19.3 in wc), neutral chamber pressure |
| Pilot Gas Pressure | Max 28 mbar (11 in wc); Min 16 mbar (6.5 in wc) |
| Combustion Air Temperature Range | ≤ 40 deg C (104 deg F) |
| Process Outlet Temperature | ≤ 500 deg C (930 deg F) |
| Process Inlet Temperature | ≤ 300 deg C (570 deg F) |
| Combustion Air Volume | 205 Nm³/h per 135 kW (120 scfm per 460,000 Btu/h) |
| Process Air Velocity | Max ≈20 m/s (≈3900 ft/min); Min ≈2 m/s (≈390 ft/min); Recommended ≈12 m/s (≈2400 ft/min) |
| Visible Flame Length | 300 mm (12 in) from whirl plate; protected by 400 mm (16 in) combustion chamber |
| Burner Start Input | 20% of nominal input |
| Mounting Options | Vertical (up/down), Horizontal (left/right), or Slot Firing |
| Heat Input Range | Cross: 675 kW (2,305,000 Btu/h) (per section); Straight: 135 kW (460,000 Btu/h); T-Section: 540 kW (1,844,000 Btu/h) |
| Turndown Ratio | 10:1 |
| Flame Detection | UV Scanner |
| Ignition Type | Spark‑ignited integral pilot, nozzle‑mix type |
| Burner Design | Ultra‑Low Emissions (ULE) nozzle‑mix burner with integrated mixer |
| Applications | Direct‑fired process air heating in ducts |
| Pilot Input | ≈15 kW (≈51,000 Btu/h) |
| Pilot Type | Integral, nozzle‑mixing, spark‑ignited; interrupted pilot |
| Model Name | Minnox ULE, V1 |
| Fuel Type | Natural Gas (H); Propane (<10% unsaturated); Butane (<10% unsaturated) |
| Emissions | NOx < 5 ppm; CO < 30 ppm; HCHO < 0.17 ppm (not guaranteed; process‑dependent) (at 3% O₂, estimated) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 00.4150003.00 | BURNERHEAD,MINNOX 500CCS | Request quotation |
| 00.4150006.00 | PLT,SIDE,MINNOX,1.5MM,253 MA,1.4835,194X | Request quotation |
| 00.4150006.01 | PLT,STABILISATION,MINNOX,253 MA,1.4835,1 | Request quotation |
| 00.4150006.02 | STRP,MTG,BED,MINNOX,AISI310,1.4541,150X6 | Request quotation |
| 00.4150006.03 | PLT,SHLD,CRNR,MINNOX,253MA,1.4835,275X33 | Request quotation |
| 00.4150006.04 | PLT,STABILISATION,CRNR,MINNOX,253MA,1.48 | Request quotation |
| 00.4150006.05 | STRP,MTG,CRNR,L,BED,MINNOX,AISI 310,1.45 | Request quotation |
| 00.4150006.06 | STRP,MTG,CRNR,R,BED,MINNOX,AISI 310,1.45 | Request quotation |
| 00.4150007.00 | PLT,SHLD,END,MINNOX,253MA,1.4835,383X267 | Request quotation |
| 00.4150007.01 | PLT,SHLD,INLT,MINNOX,253MA,1.4835,383X26 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Minnox Product Image · Manufacturer ownership retained; republication licence not independently confirmed
Minnox Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed
Minnox Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.