Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Line & Duct Burners

Minnox

Minnox uses excess-air premixing and a recirculating flame to reduce both NOx and CO in direct process-air heating.

Minnox uses excess-air premixing and a recirculating flame to reduce both NOx and CO in direct process-air heating. Custom systems typically package burner, mixer and manifold into a duct section or insertion plate. Published applications include food, malt, coatings, wood and paper; emissions figures use the stated oxygen correction.

Features & Benefits

Process Air Differential Pressure
At 10 m/s: ≈0.5 mbar (≈0.2 in wc)|At 20 m/s: ≈2.0 mbar (≈0.8 in wc) (estimated)
Combustion Air Temperature Range
≤ 40 deg C (104 deg F)
Proportionator Gas Pressure
Max 300 mbar (120 in wc)|Min 100 mbar (40 in wc)
Process Outlet Temperature
≤ 500 deg C (930 deg F)
Process Inlet Temperature
≤ 300 deg C (570 deg F)
Process Pressure Limits
Negative: ≤ 6 mbar (2.4 in wc); Positive: ≤ 10 mbar (4 in wc)
Combustion Air Pressure
48 mbar at mixer inlet (19.3 in wc), neutral chamber pressure
Combustion Air Volume
205 Nm³/h per 135 kW (120 scfm per 460,000 Btu/h)
Visible Flame Length
300 mm (12 in) from whirl plate; protected by 400 mm (16 in) combustion chamber
Process Air Velocity
Max ≈20 m/s (≈3900 ft/min)|Min ≈2 m/s (≈390 ft/min)|Recommended ≈12 m/s (≈2400 ft/min)
Pilot Gas Pressure
Max 28 mbar (11 in wc)|Min 16 mbar (6.5 in wc)
Burner Start Input
20% of nominal input
Mounting Options
Vertical (up/down), Horizontal (left/right), or Slot Firing
Heat Input Range
Cross: 675 kW (2,305,000 Btu/h) (per section)|Straight: 135 kW (460,000 Btu/h)|T-Section: 540 kW (1,844,000 Btu/h)
Flame Detection
UV Scanner
Turndown Ratio
10:1
Ignition Type
Spark‑ignited integral pilot, nozzle‑mix type
Burner Design
Ultra‑Low Emissions (ULE) nozzle‑mix burner with integrated mixer
Pilot Input
≈15 kW (≈51,000 Btu/h)
Pilot Type
Integral, nozzle‑mixing, spark‑ignited; interrupted pilot
Model Name
Minnox ULE, V1
Fuel Type
Natural Gas (H); Propane (<10% unsaturated); Butane (<10% unsaturated)
Emissions
NOx < 5 ppm; CO < 30 ppm; HCHO < 0.17 ppm (not guaranteed; process‑dependent) (at 3% O₂, estimated)
  • Low-emission direct heating avoids the efficiency penalty of a separate indirect heater.

Applications

  • Food processing
  • Malt processing
  • Automotive finishing
  • Lumber processing
  • Paper processing

Detailed capabilities

Premixed excess-air combustion

Minnox combines a lean premixed fuel/air stream with a recirculating flame pattern. Excess air lowers the flame temperature, while recirculation addresses CO, allowing direct process heating with very low reported emissions. The published NOx and CO levels use a 3% oxygen reference. They should be treated as manufacturer performance statements for the described system rather than a blanket compliance determination for every jurisdiction or installation.

Manufacturer reference ↗

Custom process integration

Minnox systems are engineered for the production duty and installation. Typical supply combines burner, mixer and manifold in a duct section or on a side plate for an existing duct. Published uses include food products, malt, automotive coatings, lumber and paper. The source associates the clean direct-heating approach with avoiding product discoloration or taste contamination, but the complete application still depends on the configured process system.

Manufacturer reference ↗

Features and benefits

  • Low-emission direct heating avoids the efficiency penalty of a separate indirect heater.

Manufacturer reference ↗

Published application context

  • Food processing
  • Malt processing
  • Automotive finishing
  • Lumber processing
  • Paper processing

Manufacturer reference ↗

Specifications

Pressure Specifications

Process Air Differential Pressure
At 10 m/s: ≈0.5 mbar (≈0.2 in wc); At 20 m/s: ≈2.0 mbar (≈0.8 in wc) (estimated)
Proportionator Gas Pressure
Max 300 mbar (120 in wc); Min 100 mbar (40 in wc)
Process Pressure Limits
Negative: ≤ 6 mbar (2.4 in wc); Positive: ≤ 10 mbar (4 in wc)
Combustion Air Pressure
48 mbar at mixer inlet (19.3 in wc), neutral chamber pressure
Pilot Gas Pressure
Max 28 mbar (11 in wc); Min 16 mbar (6.5 in wc)

Combustion/Furnace/Chamber Temperatures

Combustion Air Temperature Range
≤ 40 deg C (104 deg F)

Operating/Process Temperature Ranges

Process Outlet Temperature
≤ 500 deg C (930 deg F)
Process Inlet Temperature
≤ 300 deg C (570 deg F)

Air & Combustion Air Specifications

Combustion Air Volume
205 Nm³/h per 135 kW (120 scfm per 460,000 Btu/h)
Process Air Velocity
Max ≈20 m/s (≈3900 ft/min); Min ≈2 m/s (≈390 ft/min); Recommended ≈12 m/s (≈2400 ft/min)

Burner/Flame‑Related Lengths

Visible Flame Length
300 mm (12 in) from whirl plate; protected by 400 mm (16 in) combustion chamber

Control, Logic & System Behavior

Burner Start Input
20% of nominal input

Installation & Mounting Specifications

Mounting Options
Vertical (up/down), Horizontal (left/right), or Slot Firing

Performance, Flow & Capacity

Heat Input Range
Cross: 675 kW (2,305,000 Btu/h) (per section); Straight: 135 kW (460,000 Btu/h); T-Section: 540 kW (1,844,000 Btu/h)
Turndown Ratio
10:1

Ignition, Flame & Supervision Specifications

Flame Detection
UV Scanner
Ignition Type
Spark‑ignited integral pilot, nozzle‑mix type

Product Design & Configuration

Burner Design
Ultra‑Low Emissions (ULE) nozzle‑mix burner with integrated mixer

Applications & Compatibility

Applications
Direct‑fired process air heating in ducts

Combustion, Fuel & Mixing Sub‑Systems

Pilot Input
≈15 kW (≈51,000 Btu/h)
Pilot Type
Integral, nozzle‑mixing, spark‑ignited; interrupted pilot

Overview

Model Name
Minnox ULE, V1

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas (H); Propane (<10% unsaturated); Butane (<10% unsaturated)

Processing & Performance Metrics

Emissions
NOx < 5 ppm; CO < 30 ppm; HCHO < 0.17 ppm (not guaranteed; process‑dependent) (at 3% O₂, estimated)
Minnox — manufacturer page values
ParameterPublished value / configuration
Process Air Differential PressureAt 10 m/s: ≈0.5 mbar (≈0.2 in wc); At 20 m/s: ≈2.0 mbar (≈0.8 in wc) (estimated)
Proportionator Gas PressureMax 300 mbar (120 in wc); Min 100 mbar (40 in wc)
Process Pressure LimitsNegative: ≤ 6 mbar (2.4 in wc); Positive: ≤ 10 mbar (4 in wc)
Combustion Air Pressure48 mbar at mixer inlet (19.3 in wc), neutral chamber pressure
Pilot Gas PressureMax 28 mbar (11 in wc); Min 16 mbar (6.5 in wc)
Combustion Air Temperature Range≤ 40 deg C (104 deg F)
Process Outlet Temperature≤ 500 deg C (930 deg F)
Process Inlet Temperature≤ 300 deg C (570 deg F)
Combustion Air Volume205 Nm³/h per 135 kW (120 scfm per 460,000 Btu/h)
Process Air VelocityMax ≈20 m/s (≈3900 ft/min); Min ≈2 m/s (≈390 ft/min); Recommended ≈12 m/s (≈2400 ft/min)
Visible Flame Length300 mm (12 in) from whirl plate; protected by 400 mm (16 in) combustion chamber
Burner Start Input20% of nominal input
Mounting OptionsVertical (up/down), Horizontal (left/right), or Slot Firing
Heat Input RangeCross: 675 kW (2,305,000 Btu/h) (per section); Straight: 135 kW (460,000 Btu/h); T-Section: 540 kW (1,844,000 Btu/h)
Turndown Ratio10:1
Flame DetectionUV Scanner
Ignition TypeSpark‑ignited integral pilot, nozzle‑mix type
Burner DesignUltra‑Low Emissions (ULE) nozzle‑mix burner with integrated mixer
ApplicationsDirect‑fired process air heating in ducts
Pilot Input≈15 kW (≈51,000 Btu/h)
Pilot TypeIntegral, nozzle‑mixing, spark‑ignited; interrupted pilot
Model NameMinnox ULE, V1
Fuel TypeNatural Gas (H); Propane (<10% unsaturated); Butane (<10% unsaturated)
EmissionsNOx < 5 ppm; CO < 30 ppm; HCHO < 0.17 ppm (not guaranteed; process‑dependent) (at 3% O₂, estimated)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
00.4150003.00BURNERHEAD,MINNOX 500CCSRequest quotation
00.4150006.00PLT,SIDE,MINNOX,1.5MM,253 MA,1.4835,194XRequest quotation
00.4150006.01PLT,STABILISATION,MINNOX,253 MA,1.4835,1Request quotation
00.4150006.02STRP,MTG,BED,MINNOX,AISI310,1.4541,150X6Request quotation
00.4150006.03PLT,SHLD,CRNR,MINNOX,253MA,1.4835,275X33Request quotation
00.4150006.04PLT,STABILISATION,CRNR,MINNOX,253MA,1.48Request quotation
00.4150006.05STRP,MTG,CRNR,L,BED,MINNOX,AISI 310,1.45Request quotation
00.4150006.06STRP,MTG,CRNR,R,BED,MINNOX,AISI 310,1.45Request quotation
00.4150007.00PLT,SHLD,END,MINNOX,253MA,1.4835,383X267Request quotation
00.4150007.01PLT,SHLD,INLT,MINNOX,253MA,1.4835,383X26Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/line-and-duct-burners/minnox

Last source check: 2026-11-02

Minnox Product Image · Manufacturer ownership retained; republication licence not independently confirmed

Minnox Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed

Minnox Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.