Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Line & Duct Burners

LV AIRFLO®

LV AIRFLO addresses low-velocity duct heating with progressive aeration and small process-pressure loss.

LV AIRFLO addresses low-velocity duct heating with progressive aeration and small process-pressure loss. Modular material choices suit different thermal duties, including natural-draft arrangements. The source distinguishes general application temperatures from upstream air limits and describes tolerance of reduced oxygen without added primary air, subject to the selected burner conditions.

Features & Benefits

Air Stream Oxygen Tolerance
LV series is a raw‑gas line burner; (for operation in low O₂ streams use application‑specific engineering; bulletin provides assembly/component data rather than envelope)
Duct Static Pressure Drop
As low as 0.2 in. wc, up to 2.5 in. wc depending on application
Upstream Air Temperature
Approach air temperature options by flange kit: up to ~1000 deg F, 800 deg F, 600 deg F, 450 deg F (kit/material dependent)
Natural Gas Pressure
Typical fuel pressure guidance given by application; assembly bulletin lists physical configurations and pilot/accessory kits, not pressure tables (Max Capacity)
Modular Construction
Straight 6/12/18/24 in, 12x6 tees, 12x12 crosses; back‑inlet 12 in straight, back‑inlet crosses, 36 in “H” back‑inlet sections; end plates and ignition options
Maximum Capacity
Max - From 0.6 to 2.5 MBtu/h per lineal foot depending on burner type|Min - As low as 0.03-0.075 MBtu/h per foot, application dependent
Combustion Type
Direct‑fired line burner; burner plates (Hastelloy or stainless steel) supported by iron/bronze/stainless steel manifolds
Burner Design
In‑duct line burner for direct firing into process air streams (raw gas); partial premix options via pilots/accessories
Flame Length
Not listed in this assembly bulletin; use product datasheet/engineering for flame length
Model Name
LV AIRFLO®
Dimensions
Dimensional families provided via assembly numbers (6 in, 12 in, 18 in, 24 in straights; tees/crosses; back‑inlet sections) (12 in Section)
Fuel Type
Natural gas as standard; pilot kits available (LINOPAK AIR‑FLOW) for atmospheric or pressure types
Emissions
Designed for clean, odor‑free combustion with low CO and NOx when used within specified limits
Material
Gray Iron or Ductile Iron Bodies; Aluminum‑Bronze Bodies (with Hastelloy plates) available
  • Small duct pressure loss reduces blower power requirements.

Applications

  • Low-velocity duct heating
  • Natural-draft heating where configured

Detailed capabilities

Low-pressure-loss aeration

LV AIRFLO uses progressive aeration to retain a stable raw-gas flame at relatively low duct velocity and pressure loss. The process airstream supplies combustion conditions, with reduced oxygen tolerated within the published arrangement without adding primary air. The source gives a low pressure-drop example and permits natural-draft application where appropriate. These are selection conditions rather than evidence that every duct can operate at the minimum pressure drop.

Manufacturer reference ↗

Materials, temperatures and configuration

Seventeen varieties differ in materials or performance factors, supporting modular patterns matched to the heat release and duct. The narrative gives an overall application-temperature statement and a separate upstream-air limit; they refer to different conditions and should remain distinct. Natural gas, propane and other qualified fuels are described. Material choice and process conditions therefore need to be selected together.

Manufacturer reference ↗

Features and benefits

  • Small duct pressure loss reduces blower power requirements.

Manufacturer reference ↗

Published application context

  • Low-velocity duct heating
  • Natural-draft heating where configured

Manufacturer reference ↗

Specifications

Overview

Models
Configured by assembly numbers (e.g., VL‑42G3, VL‑121G3, VL‑42D4/5, VL‑121D4/5, etc.); order by configured item or loose assemblies
Model Name
LV AIRFLO®

Air & Combustion Air Specifications

Air Stream Oxygen Tolerance
LV series is a raw‑gas line burner; (for operation in low O₂ streams use application‑specific engineering; bulletin provides assembly/component data rather than envelope)

Pressure Specifications

Duct Static Pressure Drop
As low as 0.2 in. wc, up to 2.5 in. wc depending on application
Natural Gas Pressure
Typical fuel pressure guidance given by application; assembly bulletin lists physical configurations and pilot/accessory kits, not pressure tables (Max Capacity)

Air/Exhaust/Flue Gas Temperatures

Upstream Air Temperature
Approach air temperature options by flange kit: up to ~1000 deg F, 800 deg F, 600 deg F, 450 deg F (kit/material dependent)

Product Overview & Classification

Modular Construction
Straight 6/12/18/24 in, 12x6 tees, 12x12 crosses; back‑inlet 12 in straight, back‑inlet crosses, 36 in “H” back‑inlet sections; end plates and ignition options

Processing & Performance Metrics

Maximum Capacity
Max - From 0.6 to 2.5 MBtu/h per lineal foot depending on burner type; Min - As low as 0.03-0.075 MBtu/h per foot, application dependent
Emissions
Designed for clean, odor‑free combustion with low CO and NOx when used within specified limits

Combustion Design & Characteristics

Combustion Type
Direct‑fired line burner; burner plates (Hastelloy or stainless steel) supported by iron/bronze/stainless steel manifolds

Product Design & Configuration

Burner Design
In‑duct line burner for direct firing into process air streams (raw gas); partial premix options via pilots/accessories

Burner/Flame‑Related Lengths

Flame Length
Not listed in this assembly bulletin; use product datasheet/engineering for flame length

Applications & Compatibility

Applications
General in‑duct process air heating; bulletin is a parts/assembly catalog—application list not enumerated here

Dimensions & Weight

Dimensions
Dimensional families provided via assembly numbers (6 in, 12 in, 18 in, 24 in straights; tees/crosses; back‑inlet sections) (12 in Section)

Fuel, Gas & Media Specifications

Fuel Type
Natural gas as standard; pilot kits available (LINOPAK AIR‑FLOW) for atmospheric or pressure types

Material Specifications

Material
Gray Iron or Ductile Iron Bodies; Aluminum‑Bronze Bodies (with Hastelloy plates) available
LV AIRFLO® — manufacturer page values
ParameterPublished value / configuration
ModelsConfigured by assembly numbers (e.g., VL‑42G3, VL‑121G3, VL‑42D4/5, VL‑121D4/5, etc.); order by configured item or loose assemblies
Model NameLV AIRFLO®
Air Stream Oxygen ToleranceLV series is a raw‑gas line burner; (for operation in low O₂ streams use application‑specific engineering; bulletin provides assembly/component data rather than envelope)
Duct Static Pressure DropAs low as 0.2 in. wc, up to 2.5 in. wc depending on application
Natural Gas PressureTypical fuel pressure guidance given by application; assembly bulletin lists physical configurations and pilot/accessory kits, not pressure tables (Max Capacity)
Upstream Air TemperatureApproach air temperature options by flange kit: up to ~1000 deg F, 800 deg F, 600 deg F, 450 deg F (kit/material dependent)
Modular ConstructionStraight 6/12/18/24 in, 12x6 tees, 12x12 crosses; back‑inlet 12 in straight, back‑inlet crosses, 36 in “H” back‑inlet sections; end plates and ignition options
Maximum CapacityMax - From 0.6 to 2.5 MBtu/h per lineal foot depending on burner type; Min - As low as 0.03-0.075 MBtu/h per foot, application dependent
EmissionsDesigned for clean, odor‑free combustion with low CO and NOx when used within specified limits
Combustion TypeDirect‑fired line burner; burner plates (Hastelloy or stainless steel) supported by iron/bronze/stainless steel manifolds
Burner DesignIn‑duct line burner for direct firing into process air streams (raw gas); partial premix options via pilots/accessories
Flame LengthNot listed in this assembly bulletin; use product datasheet/engineering for flame length
ApplicationsGeneral in‑duct process air heating; bulletin is a parts/assembly catalog—application list not enumerated here
DimensionsDimensional families provided via assembly numbers (6 in, 12 in, 18 in, 24 in straights; tees/crosses; back‑inlet sections) (12 in Section)
Fuel TypeNatural gas as standard; pilot kits available (LINOPAK AIR‑FLOW) for atmospheric or pressure types
MaterialGray Iron or Ductile Iron Bodies; Aluminum‑Bronze Bodies (with Hastelloy plates) available

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
0150BBIF1.5" B Back Inlet FlangeRequest quotation
0150DBIF1.5" D Back Inlet FlangeRequest quotation
0200BBIF2" B Back Inlet FlangeRequest quotation
0200DBIF2" D Back Inlet FlangeRequest quotation
0250BBIF2.5" B Back Inlet FlangeRequest quotation
0250DBIF2.5" D Back Inlet FlangeRequest quotation
0300BBIF3" B Back Inlet FlangeRequest quotation
0300DBIF3" D Back Inlet FlangeRequest quotation
0300DXIF3" D Cross Inlet FlangeRequest quotation
0400DBIF4" D Back Inlet FlangeRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/line-and-duct-burners/lv-airflo

Last source check: 2026-11-02

LV Airflo Product Image · Manufacturer ownership retained; republication licence not independently confirmed

LV Airflo Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry