LINOFLAME®

LINOFLAME produces short ribbon flames from modular sections.

LINOFLAME produces short ribbon flames from modular sections. Styles A and B use application-specific drilling, while VF uses standardized drilling in V-faced cast-iron sections. Published duties include foam lamination, dip tanks, hot-oil cooking, glass-surface treatment and general air heating, with the arrangement selected for the required heat pattern.

Features & Benefits

Ambient Temperature Range
Downstream temp limits: ~1000 deg F (recirculated air) or ~1200 deg F (fresh air)|Styles A/B/C - Ambient/return air over burner should not exceed ~600 deg F (316 deg C), VF - Ambient/return air up to ~800 deg F (427 deg C)
Turndown Ratio
Up to 10:1 (style and premix equipment dependent)
Section Configuration
Over 200 modular section types in multiple shapes and sizes
Process Air Velocity
VF limits up to 3000-4000 SFPM|≤ 1000 SFPM for side‑inlet tees (Styles A/B/C)
Pilot Type
LINOPAK® pilots: atmospheric, pressure, and venturi types; available for low/medium/high gas pressures; UV or flame‑rod flame safeguard
Material
Cast iron burner bodies; ignition rails in cast iron or alloy (alloy recommended for propane or >400 deg F applications)
Manifold Design
Cast iron air‑gas manifold with drilled face
Inlet Feed Capacity
Inlet flange size limits burner footage and total Btu/hr per feed
Ignition Type
Direct spark ignition or LINOPAK® pilot systems
Heat Release
Style A - Up to 525,000 Btu/hr per lineal ft @ 7.5 in. wc mixture pressure, Style B - Up to 250,000 Btu/hr per lineal ft @ 13 in. wc mixture pressure, Style C - Up to 25,000 Btu/hr per lineal ft @ 2.5 in. wc mixture pressure|VFH: up to 600,000 Btu/hr/ft; VFL: up to 300,000 Btu/hr/ft @ 10 in. wc mixture pressure
Fuel Type
Natural Gas, Propane (alloy ignition rails recommended for Propane)
Flame Retention
Replaceable ignition rail (“zipper channel”) for flame retention and cross‑ignition
Flame Detection
Flame rod or UV scanner (configuration dependent)
Compatible Mixers
PREMIX® blowers, LG/HG mixing tubes, MULTI‑RATIO™ mixers, VENTITE™ inspirators
Combustion Method
Full air/gas premix producing a ribbon‑type flame
Burner Type
Premix line burners: LINOFLAME® Styles A/B/C (ribbon flame), Type VF (VFL low-capacity, VFH high-capacity)|VFH (high capacity) and VFL (low capacity) V‑faced burners
Burner Style
Style A, Style B, Style C, and Type “VF” (V‑faced)
Burner Design
Premix‑type line burner

Applications

  • Foam lamination
  • Dip tanks
  • Hot-oil cooking
  • Glass-surface treatment
  • General air heating

Specifications

Environmental Conditions

Ambient Temperature Range
Downstream temp limits: ~1000 deg F (recirculated air) or ~1200 deg F (fresh air); Styles A/B/C - Ambient/return air over burner should not exceed ~600 deg F (316 deg C), VF - Ambient/return air up to ~800 deg F (427 deg C)

Performance, Flow & Capacity

Turndown Ratio
Up to 10:1 (style and premix equipment dependent)
Heat Release
Style A - Up to 525,000 Btu/hr per lineal ft @ 7.5 in. wc mixture pressure, Style B - Up to 250,000 Btu/hr per lineal ft @ 13 in. wc mixture pressure, Style C - Up to 25,000 Btu/hr per lineal ft @ 2.5 in. wc mixture pressure; VFH: up to 600,000 Btu/hr/ft; VFL: up to 300,000 Btu/hr/ft @ 10 in. wc mixture pressure

Combustion, Fuel & Mixing Sub‑Systems

Section Configuration
Over 200 modular section types in multiple shapes and sizes
Pilot Type
LINOPAK® pilots: atmospheric, pressure, and venturi types; available for low/medium/high gas pressures; UV or flame‑rod flame safeguard

Air & Combustion Air Specifications

Process Air Velocity
VF limits up to 3000-4000 SFPM; ≤ 1000 SFPM for side‑inlet tees (Styles A/B/C)

Material Specifications

Material
Cast iron burner bodies; ignition rails in cast iron or alloy (alloy recommended for propane or >400 deg F applications)

Mechanical Design & Adjustment Characteristics

Manifold Design
Cast iron air‑gas manifold with drilled face

Processing & Performance Metrics

Inlet Feed Capacity
Inlet flange size limits burner footage and total Btu/hr per feed

Ignition, Flame & Supervision Specifications

Ignition Type
Direct spark ignition or LINOPAK® pilot systems
Flame Retention
Replaceable ignition rail (“zipper channel”) for flame retention and cross‑ignition
Flame Detection
Flame rod or UV scanner (configuration dependent)

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas, Propane (alloy ignition rails recommended for Propane)

Applications & Compatibility

Compatible Mixers
PREMIX® blowers, LG/HG mixing tubes, MULTI‑RATIO™ mixers, VENTITE™ inspirators

Combustion Design & Characteristics

Combustion Method
Full air/gas premix producing a ribbon‑type flame

Overview

Burner Type
Premix line burners: LINOFLAME® Styles A/B/C (ribbon flame), Type VF (VFL low-capacity, VFH high-capacity); VFH (high capacity) and VFL (low capacity) V‑faced burners

Product Design & Configuration

Burner Style
Style A, Style B, Style C, and Type “VF” (V‑faced)
Burner Design
Premix‑type line burner
LINOFLAME® — manufacturer page values
ParameterPublished value / configuration
Ambient Temperature RangeDownstream temp limits: ~1000 deg F (recirculated air) or ~1200 deg F (fresh air); Styles A/B/C - Ambient/return air over burner should not exceed ~600 deg F (316 deg C), VF - Ambient/return air up to ~800 deg F (427 deg C)
Turndown RatioUp to 10:1 (style and premix equipment dependent)
Heat ReleaseStyle A - Up to 525,000 Btu/hr per lineal ft @ 7.5 in. wc mixture pressure, Style B - Up to 250,000 Btu/hr per lineal ft @ 13 in. wc mixture pressure, Style C - Up to 25,000 Btu/hr per lineal ft @ 2.5 in. wc mixture pressure; VFH: up to 600,000 Btu/hr/ft; VFL: up to 300,000 Btu/hr/ft @ 10 in. wc mixture pressure
Section ConfigurationOver 200 modular section types in multiple shapes and sizes
Pilot TypeLINOPAK® pilots: atmospheric, pressure, and venturi types; available for low/medium/high gas pressures; UV or flame‑rod flame safeguard
Process Air VelocityVF limits up to 3000-4000 SFPM; ≤ 1000 SFPM for side‑inlet tees (Styles A/B/C)
MaterialCast iron burner bodies; ignition rails in cast iron or alloy (alloy recommended for propane or >400 deg F applications)
Manifold DesignCast iron air‑gas manifold with drilled face
Inlet Feed CapacityInlet flange size limits burner footage and total Btu/hr per feed
Ignition TypeDirect spark ignition or LINOPAK® pilot systems
Flame RetentionReplaceable ignition rail (“zipper channel”) for flame retention and cross‑ignition
Flame DetectionFlame rod or UV scanner (configuration dependent)
Fuel TypeNatural Gas, Propane (alloy ignition rails recommended for Propane)
Compatible MixersPREMIX® blowers, LG/HG mixing tubes, MULTI‑RATIO™ mixers, VENTITE™ inspirators
Combustion MethodFull air/gas premix producing a ribbon‑type flame
Burner TypePremix line burners: LINOFLAME® Styles A/B/C (ribbon flame), Type VF (VFL low-capacity, VFH high-capacity); VFH (high capacity) and VFL (low capacity) V‑faced burners
Burner StyleStyle A, Style B, Style C, and Type “VF” (V‑faced)
Burner DesignPremix‑type line burner

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
002953" BTTM INLT FLGRequest quotation
016297-007PKG, 20/10,3/16 IN. SQ,5.75 IN. LENGRequest quotation
0184312" A STR BDYRequest quotation
018466" A ELB BDYRequest quotation
01860LEP END PLTRequest quotation
0197512" A BACK INLT TEE BDYRequest quotation
0233012" B ANSI BACK INLT STR BDYRequest quotation
024214ELBA-12B-24 BOSSED BI SECT.ISORequest quotation
024215ELBA-12S-24 BOSSED SI SECT.ISORequest quotation
024233ELBA-12B-36 BOSSED BI SECT.ISORequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/line-and-duct-burners/linoflame

Last source check: 2026-11-02

LINOFLAME Product Image · Manufacturer ownership retained; republication licence not independently confirmed

LINOFLAME Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry