Shutoff Valves
V4944B, L, N/8944B, C, L, N Two-stage pressure regulating gas valves
V4944/V8944 combines two-stage pressure regulation and safety shutoff for gas appliances.
V4944/V8944 combines two-stage pressure regulation and safety shutoff for gas appliances. B/N versions serve natural gas while C/L versions serve LP gas, and the two voltage families use different controllers. The source identifies V4844/V8844 replacement use, with mounting, closing time and electrical demand qualified by the exact model.
Features & Benefits
- Ambient Temperature Range
- -40 to +150 deg F (-40 to +66 deg C)
- Fluid Temperature Range
- 150 deg F (66 deg C)
- Electrical Connections
- 1/4 in spade terminals|Leadwires and conduit cover included
- Maintenance Interval
- Periodic leak testing and regulator verification recommended
- Valve Body Material
- Die-Cast Aluminum
- Flow Capacity Range
- Approximately 400 kBtu/h to 5,000 kBtu/h, size and application dependent
- Mounting Position
- Horizontal upright (electrical tower up); limited horizontal allowed
- Voltage Rating
- V4944: 120 VAC, 60 Hz (line‑voltage, dual‑stage control)|V8944: 24 VAC (dual‑stage control)
- Valve Pattern
- Straight-through, non-offset
- Opening Time
- Rapid opening (<6 seconds)
- Closing Time
- Fast closing (≤2 seconds on power failure)
- Valve Type
- Two‑stage, solenoid‑operated diaphragm gas valves with pressure regulation
- Pipe Size
- 1 in, 1-1/4 in, 1-1/2 in NPT
- Approvals
- File MH1639, Guide YIOZ, ANSI Z21.21 Compliance Valve leak test and allowable leakage rates
- Gas Type
- Natural Gas, LPG
- Bleed Tapping
- Two 5/16-24 UNF
- Pilot Tapping
- 1/8-27 NPT
- Valve Closing Time
- 2 sec max
- Voltage
- V4944-120 Vac; V8944-24 Vac
- Frequency
- 60 Hz
- Power Consumption
- V4944-9 VA max; V8944-12.4 VA max
- Operating Temperature Range
- -40°F to +150°F (-40°C to +66°C)
- Approvals, Underwriters Laboratories Inc.
- File No. MH1639, Guide No. YIOZ (60 Hz only)
- Approvals, CSA
- Certificate No. 158158-1042930, Guide No. 3302-01, 81 (Z21.21, Z21.78)
- Pressure Ratings (psi)
- 1/2 psi
- Pressure Ratings (kPa)
- 3.4 kPa
- Current Ratings
- V4944-0.077 max amps at rated Vac/Hz; V8944-0.516 max amps at rated Vac/Hz
- Combining safety shutoff and regulation reduces separate components.
Applications
- Atmospheric boilers
- Commercial water heaters
- Rooftop heaters
Detailed capabilities
Two-stage regulation and fuel suffixes
These valves combine gas regulation and shutoff in one diaphragm-operated body. B/N forms are identified for natural gas, and C/L forms for LP gas. V4944 uses the line-voltage two-stage controller arrangement, while V8944 uses the 24 V two-stage control group. Suffix and voltage family therefore must be selected together with the fuel rather than chosen independently.
Replacement context and installation
The source identifies V4844/V8844 replacement use for boilers, water heaters and rooftop equipment. Upright mounting, bleed/pilot tapping and spade-terminal wiring are specified, and the valve shuts on power loss. Electrical demand differs between the two voltage families. The published pressure, temperature and two-second closing limit apply with the stated regional/frequency approval conditions.
Features and benefits
- Combining safety shutoff and regulation reduces separate components.
Published application context
- Atmospheric boilers
- Commercial water heaters
- Rooftop heaters
Technical facts in the product overview
- Bleed Tapping: Two 5/16-24 UNF
- Pilot Tapping: 1/8-27 NPT
- Valve Closing Time: 2 sec max
- Voltage: V4944-120 Vac; V8944-24 Vac
- Frequency: 60 Hz
- Power Consumption: V4944-9 VA max; V8944-12.4 VA max
- Operating Temperature Range: -40°F to +150°F (-40°C to +66°C)
- Approvals, Underwriters Laboratories Inc.: File No. MH1639, Guide No. YIOZ (60 Hz only)
- Approvals, CSA: Certificate No. 158158-1042930, Guide No. 3302-01, 81 (Z21.21, Z21.78)
- Pressure Ratings (psi): 1/2 psi
- Pressure Ratings (kPa): 3.4 kPa
- Current Ratings: V4944-0.077 max amps at rated Vac/Hz; V8944-0.516 max amps at rated Vac/Hz
Overview
- Models
- V4944N1086, V4944N1094, V4944N1102
Environmental Conditions
- Ambient Temperature Range
- -40 to +150 deg F (-40 to +66 deg C)
Fluid/Media/Component Temperatures
- Fluid Temperature Range
- 150 deg F (66 deg C)
Connections & Interfaces
- Electrical Connections
- 1/4 in spade terminals; Leadwires and conduit cover included
Electrical Specifications
- Maintenance Interval
- Periodic leak testing and regulator verification recommended
- Voltage Rating
- V4944: 120 VAC, 60 Hz (line‑voltage, dual‑stage control); V8944: 24 VAC (dual‑stage control)
Material Specifications
- Valve Body Material
- Die-Cast Aluminum
Processing & Performance Metrics
- Flow Capacity Range
- Approximately 400 kBtu/h to 5,000 kBtu/h, size and application dependent
Installation & Mounting Specifications
- Mounting Position
- Horizontal upright (electrical tower up); limited horizontal allowed
Actuation, Valve & Motion Control Specifications
- Valve Pattern
- Straight-through, non-offset
- Opening Time
- Rapid opening (<6 seconds)
- Closing Time
- Fast closing (≤2 seconds on power failure)
- Valve Type
- Two‑stage, solenoid‑operated diaphragm gas valves with pressure regulation
Applications & Compatibility
- Applications
- Boilers, unit heaters, duct furnaces, makeup‑air units, rooftop heaters, ovens, incinerators, and commercial/industrial burners
Dimensions & Size Specifications
- Pipe Size
- 1 in, 1-1/4 in, 1-1/2 in NPT
Standards & Certifications
- Approvals
- File MH1639, Guide YIOZ, ANSI Z21.21 Compliance Valve leak test and allowable leakage rates
Fuel, Gas & Media Specifications
- Gas Type
- Natural Gas, LPG
Technical Specifications
- Bleed Tapping
- Two 5/16-24 UNF
- Pilot Tapping
- 1/8-27 NPT
- Valve Closing Time
- 2 sec max
- Voltage
- V4944-120 Vac; V8944-24 Vac
- Frequency
- 60 Hz
- Power Consumption
- V4944-9 VA max; V8944-12.4 VA max
- Operating Temperature Range
- -40°F to +150°F (-40°C to +66°C)
- Approvals, Underwriters Laboratories Inc.
- File No. MH1639, Guide No. YIOZ (60 Hz only)
- Approvals, CSA
- Certificate No. 158158-1042930, Guide No. 3302-01, 81 (Z21.21, Z21.78)
- Pressure Ratings (psi)
- 1/2 psi
- Pressure Ratings (kPa)
- 3.4 kPa
- Current Ratings
- V4944-0.077 max amps at rated Vac/Hz; V8944-0.516 max amps at rated Vac/Hz
| Parameter | Published value / configuration |
|---|---|
| Models | V4944N1086, V4944N1094, V4944N1102 |
| Ambient Temperature Range | -40 to +150 deg F (-40 to +66 deg C) |
| Fluid Temperature Range | 150 deg F (66 deg C) |
| Electrical Connections | 1/4 in spade terminals; Leadwires and conduit cover included |
| Maintenance Interval | Periodic leak testing and regulator verification recommended |
| Voltage Rating | V4944: 120 VAC, 60 Hz (line‑voltage, dual‑stage control); V8944: 24 VAC (dual‑stage control) |
| Valve Body Material | Die-Cast Aluminum |
| Flow Capacity Range | Approximately 400 kBtu/h to 5,000 kBtu/h, size and application dependent |
| Mounting Position | Horizontal upright (electrical tower up); limited horizontal allowed |
| Valve Pattern | Straight-through, non-offset |
| Opening Time | Rapid opening (<6 seconds) |
| Closing Time | Fast closing (≤2 seconds on power failure) |
| Valve Type | Two‑stage, solenoid‑operated diaphragm gas valves with pressure regulation |
| Applications | Boilers, unit heaters, duct furnaces, makeup‑air units, rooftop heaters, ovens, incinerators, and commercial/industrial burners |
| Pipe Size | 1 in, 1-1/4 in, 1-1/2 in NPT |
| Approvals | File MH1639, Guide YIOZ, ANSI Z21.21 Compliance Valve leak test and allowable leakage rates |
| Gas Type | Natural Gas, LPG |
| Bleed Tapping | Two 5/16-24 UNF |
| Pilot Tapping | 1/8-27 NPT |
| Valve Closing Time | 2 sec max |
| Voltage | V4944-120 Vac; V8944-24 Vac |
| Frequency | 60 Hz |
| Power Consumption | V4944-9 VA max; V8944-12.4 VA max |
| Operating Temperature Range | -40°F to +150°F (-40°C to +66°C) |
| Approvals, Underwriters Laboratories Inc. | File No. MH1639, Guide No. YIOZ (60 Hz only) |
| Approvals, CSA | Certificate No. 158158-1042930, Guide No. 3302-01, 81 (Z21.21, Z21.78) |
| Pressure Ratings (psi) | 1/2 psi |
| Pressure Ratings (kPa) | 3.4 kPa |
| Current Ratings | V4944-0.077 max amps at rated Vac/Hz; V8944-0.516 max amps at rated Vac/Hz |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| V4944B1018/U | 1" VALVE-REPLACMT FOR V4844B1050 | Request quotation |
| V4944B1026/U | 1-1/4" VALVE, 54" LEADWIRES | Request quotation |
| V4944B1034/U | 1-1/2",54"LEADWIRES. | Request quotation |
| V4944B1042/U | 2" | Request quotation |
| V4944B1059/U | 1" GAS VALVE | Request quotation |
| V4944B1075/U | 1" VALVE-NPT WITH 1.4 - 4.2" WC LOW FI | Request quotation |
| V4944B1083/U | 1-1/4" VALVE-NPT WITH 1.4 - 4.2" WC LO | Request quotation |
| V4944B1091/U | 1-1/2" VALVE-NPT WITH 1.4 - 4.2" WC LO | Request quotation |
| V4944B1109/U | 1" GAS VALVE | Request quotation |
| V4944B1125/U | 1-1/4" GAS VALVE | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
V8944 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.