Honeywell Process Measurement & Control

Shutoff Valves

V4944B, L, N/8944B, C, L, N Two-stage pressure regulating gas valves

V4944/V8944 combines two-stage pressure regulation and safety shutoff for gas appliances.

V4944/V8944 combines two-stage pressure regulation and safety shutoff for gas appliances. B/N versions serve natural gas while C/L versions serve LP gas, and the two voltage families use different controllers. The source identifies V4844/V8844 replacement use, with mounting, closing time and electrical demand qualified by the exact model.

Features & Benefits

Ambient Temperature Range
-40 to +150 deg F (-40 to +66 deg C)
Fluid Temperature Range
150 deg F (66 deg C)
Electrical Connections
1/4 in spade terminals|Leadwires and conduit cover included
Maintenance Interval
Periodic leak testing and regulator verification recommended
Valve Body Material
Die-Cast Aluminum
Flow Capacity Range
Approximately 400 kBtu/h to 5,000 kBtu/h, size and application dependent
Mounting Position
Horizontal upright (electrical tower up); limited horizontal allowed
Voltage Rating
V4944: 120 VAC, 60 Hz (line‑voltage, dual‑stage control)|V8944: 24 VAC (dual‑stage control)
Valve Pattern
Straight-through, non-offset
Opening Time
Rapid opening (<6 seconds)
Closing Time
Fast closing (≤2 seconds on power failure)
Valve Type
Two‑stage, solenoid‑operated diaphragm gas valves with pressure regulation
Pipe Size
1 in, 1-1/4 in, 1-1/2 in NPT
Approvals
File MH1639, Guide YIOZ, ANSI Z21.21 Compliance Valve leak test and allowable leakage rates
Gas Type
Natural Gas, LPG
Bleed Tapping
Two 5/16-24 UNF
Pilot Tapping
1/8-27 NPT
Valve Closing Time
2 sec max
Voltage
V4944-120 Vac; V8944-24 Vac
Frequency
60 Hz
Power Consumption
V4944-9 VA max; V8944-12.4 VA max
Operating Temperature Range
-40°F to +150°F (-40°C to +66°C)
Approvals, Underwriters Laboratories Inc.
File No. MH1639, Guide No. YIOZ (60 Hz only)
Approvals, CSA
Certificate No. 158158-1042930, Guide No. 3302-01, 81 (Z21.21, Z21.78)
Pressure Ratings (psi)
1/2 psi
Pressure Ratings (kPa)
3.4 kPa
Current Ratings
V4944-0.077 max amps at rated Vac/Hz; V8944-0.516 max amps at rated Vac/Hz
  • Combining safety shutoff and regulation reduces separate components.

Applications

  • Atmospheric boilers
  • Commercial water heaters
  • Rooftop heaters

Detailed capabilities

Two-stage regulation and fuel suffixes

These valves combine gas regulation and shutoff in one diaphragm-operated body. B/N forms are identified for natural gas, and C/L forms for LP gas. V4944 uses the line-voltage two-stage controller arrangement, while V8944 uses the 24 V two-stage control group. Suffix and voltage family therefore must be selected together with the fuel rather than chosen independently.

Manufacturer reference ↗

Replacement context and installation

The source identifies V4844/V8844 replacement use for boilers, water heaters and rooftop equipment. Upright mounting, bleed/pilot tapping and spade-terminal wiring are specified, and the valve shuts on power loss. Electrical demand differs between the two voltage families. The published pressure, temperature and two-second closing limit apply with the stated regional/frequency approval conditions.

Manufacturer reference ↗

Features and benefits

  • Combining safety shutoff and regulation reduces separate components.

Manufacturer reference ↗

Published application context

  • Atmospheric boilers
  • Commercial water heaters
  • Rooftop heaters

Manufacturer reference ↗

Technical facts in the product overview

  • Bleed Tapping: Two 5/16-24 UNF
  • Pilot Tapping: 1/8-27 NPT
  • Valve Closing Time: 2 sec max
  • Voltage: V4944-120 Vac; V8944-24 Vac
  • Frequency: 60 Hz
  • Power Consumption: V4944-9 VA max; V8944-12.4 VA max
  • Operating Temperature Range: -40°F to +150°F (-40°C to +66°C)
  • Approvals, Underwriters Laboratories Inc.: File No. MH1639, Guide No. YIOZ (60 Hz only)
  • Approvals, CSA: Certificate No. 158158-1042930, Guide No. 3302-01, 81 (Z21.21, Z21.78)
  • Pressure Ratings (psi): 1/2 psi
  • Pressure Ratings (kPa): 3.4 kPa
  • Current Ratings: V4944-0.077 max amps at rated Vac/Hz; V8944-0.516 max amps at rated Vac/Hz

Manufacturer reference ↗

Specifications

Overview

Models
V4944N1086, V4944N1094, V4944N1102

Environmental Conditions

Ambient Temperature Range
-40 to +150 deg F (-40 to +66 deg C)

Fluid/Media/Component Temperatures

Fluid Temperature Range
150 deg F (66 deg C)

Connections & Interfaces

Electrical Connections
1/4 in spade terminals; Leadwires and conduit cover included

Electrical Specifications

Maintenance Interval
Periodic leak testing and regulator verification recommended
Voltage Rating
V4944: 120 VAC, 60 Hz (line‑voltage, dual‑stage control); V8944: 24 VAC (dual‑stage control)

Material Specifications

Valve Body Material
Die-Cast Aluminum

Processing & Performance Metrics

Flow Capacity Range
Approximately 400 kBtu/h to 5,000 kBtu/h, size and application dependent

Installation & Mounting Specifications

Mounting Position
Horizontal upright (electrical tower up); limited horizontal allowed

Actuation, Valve & Motion Control Specifications

Valve Pattern
Straight-through, non-offset
Opening Time
Rapid opening (<6 seconds)
Closing Time
Fast closing (≤2 seconds on power failure)
Valve Type
Two‑stage, solenoid‑operated diaphragm gas valves with pressure regulation

Applications & Compatibility

Applications
Boilers, unit heaters, duct furnaces, makeup‑air units, rooftop heaters, ovens, incinerators, and commercial/industrial burners

Dimensions & Size Specifications

Pipe Size
1 in, 1-1/4 in, 1-1/2 in NPT

Standards & Certifications

Approvals
File MH1639, Guide YIOZ, ANSI Z21.21 Compliance Valve leak test and allowable leakage rates

Fuel, Gas & Media Specifications

Gas Type
Natural Gas, LPG

Technical Specifications

Bleed Tapping
Two 5/16-24 UNF
Pilot Tapping
1/8-27 NPT
Valve Closing Time
2 sec max
Voltage
V4944-120 Vac; V8944-24 Vac
Frequency
60 Hz
Power Consumption
V4944-9 VA max; V8944-12.4 VA max
Operating Temperature Range
-40°F to +150°F (-40°C to +66°C)
Approvals, Underwriters Laboratories Inc.
File No. MH1639, Guide No. YIOZ (60 Hz only)
Approvals, CSA
Certificate No. 158158-1042930, Guide No. 3302-01, 81 (Z21.21, Z21.78)
Pressure Ratings (psi)
1/2 psi
Pressure Ratings (kPa)
3.4 kPa
Current Ratings
V4944-0.077 max amps at rated Vac/Hz; V8944-0.516 max amps at rated Vac/Hz
V4944B, L, N/8944B, C, L, N Two-stage pressure regulating gas valves — manufacturer page values
ParameterPublished value / configuration
ModelsV4944N1086, V4944N1094, V4944N1102
Ambient Temperature Range-40 to +150 deg F (-40 to +66 deg C)
Fluid Temperature Range150 deg F (66 deg C)
Electrical Connections1/4 in spade terminals; Leadwires and conduit cover included
Maintenance IntervalPeriodic leak testing and regulator verification recommended
Voltage RatingV4944: 120 VAC, 60 Hz (line‑voltage, dual‑stage control); V8944: 24 VAC (dual‑stage control)
Valve Body MaterialDie-Cast Aluminum
Flow Capacity RangeApproximately 400 kBtu/h to 5,000 kBtu/h, size and application dependent
Mounting PositionHorizontal upright (electrical tower up); limited horizontal allowed
Valve PatternStraight-through, non-offset
Opening TimeRapid opening (<6 seconds)
Closing TimeFast closing (≤2 seconds on power failure)
Valve TypeTwo‑stage, solenoid‑operated diaphragm gas valves with pressure regulation
ApplicationsBoilers, unit heaters, duct furnaces, makeup‑air units, rooftop heaters, ovens, incinerators, and commercial/industrial burners
Pipe Size1 in, 1-1/4 in, 1-1/2 in NPT
ApprovalsFile MH1639, Guide YIOZ, ANSI Z21.21 Compliance Valve leak test and allowable leakage rates
Gas TypeNatural Gas, LPG
Bleed TappingTwo 5/16-24 UNF
Pilot Tapping1/8-27 NPT
Valve Closing Time2 sec max
VoltageV4944-120 Vac; V8944-24 Vac
Frequency60 Hz
Power ConsumptionV4944-9 VA max; V8944-12.4 VA max
Operating Temperature Range-40°F to +150°F (-40°C to +66°C)
Approvals, Underwriters Laboratories Inc.File No. MH1639, Guide No. YIOZ (60 Hz only)
Approvals, CSACertificate No. 158158-1042930, Guide No. 3302-01, 81 (Z21.21, Z21.78)
Pressure Ratings (psi)1/2 psi
Pressure Ratings (kPa)3.4 kPa
Current RatingsV4944-0.077 max amps at rated Vac/Hz; V8944-0.516 max amps at rated Vac/Hz

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
V4944B1018/U1" VALVE-REPLACMT FOR V4844B1050Request quotation
V4944B1026/U1-1/4" VALVE, 54" LEADWIRESRequest quotation
V4944B1034/U1-1/2",54"LEADWIRES.Request quotation
V4944B1042/U2"Request quotation
V4944B1059/U1" GAS VALVERequest quotation
V4944B1075/U1" VALVE-NPT WITH 1.4 - 4.2" WC LOW FIRequest quotation
V4944B1083/U1-1/4" VALVE-NPT WITH 1.4 - 4.2" WC LORequest quotation
V4944B1091/U1-1/2" VALVE-NPT WITH 1.4 - 4.2" WC LORequest quotation
V4944B1109/U1" GAS VALVERequest quotation
V4944B1125/U1-1/4" GAS VALVERequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/fuel-and-air-delivery/shutoff-valves/v4944b-l-n-8944b-c-l-n-two-stage-pressure-regulating-gas-valves

Last source check: 2026-11-02

V8944 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry