Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Shutoff Valves

Motorized valves for gas VK

VK motorized gas safety valves close when deenergized and provide slow opening with rapid closing.

VK motorized gas safety valves close when deenergized and provide slow opening with rapid closing. Suffixes distinguish two-step operation, higher-pressure drives, ductile-iron housings and explosion-proof versions. Optional flow adjustment, indication and manual restart add functions, with supply voltage and pressure capability matched to the exact valve configuration.

Features & Benefits

Gas Type
Natural Gas, Town Gas, LPG (gaseous), Biogas, Hydrogen, landfill gas, Clean Air
Storage/Transport Temperature Range
-20 to +40 deg C
Explosion Protection Marking
ATEX: II 2G Ex eb ob IIC T5 Gb; IECEx: Ex eb ob IIC T5 Gb
Maximum Installation Height
2000 m AMSL
Ambient Temperature Range
VK, VK..H, VK..Z: -15 to +60 deg C|VK..X, VK..HX: -15 to +40 deg C
Installation Orientation
Vertical upright or tilted (not upside down)
Explosion-Proof Versions
VK..X, VK..HX (Zone 1 and 2, ATEX and IECEx compliant)
Electrical Connections
Plug (EN 175301-803), M20 cable gland, terminal (2.5 mm²)
Maintenance Interval
At least once a year; twice for biogas applications
Inlet Pressure Range
Up to 8 bar depending on model
Valve Body Material
Aluminum alloy (AlSi) or GGG 40 cast iron (flanged versions)
Valve Plate Seal
Perbunan, Viton
Enclosure Rating
IP54 (standard), IP65 (explosion-proof versions)
Connection Type
Rp Internal Thread (ISO 7-1), Flange (ISO 7005, PN 16)
Nominal Sizes
DN 40 to 250
Mains Voltage
24 VDC, 100 to 240 VAC, 50/60 Hz
Actuator Type
Hydraulically actuated, closed when de-energized
Safety Class
Class 1
Product Type
Motorized valve for gas
Opening Time
DN 40: 5 seconds; DN 50-65: 8 seconds; DN 80-100: 10 seconds; DN 125-200: 13 seconds; DN 250: -
Closing Time
<1 seconds
Duty Cycle
1
Approvals
CE (GAR, PED, EMC, LVD), UKCA, AGA, IECEx, ATEX, EAC
DN
40 to 250
pu
max. 230 mbar to max. 8 bar
  • Fail-closed operation isolates supply when electrical power is removed.

Applications

  • Automatic gas/air shutoff

Detailed capabilities

VK suffix and restart options

Z denotes two-step action, G the stated ductile-iron housing applications, H a stronger drive and X the described explosion-proof version. Further options provide flow adjustment, position indication, a holding relay for manual restart or Viton sealing. Slow opening and rapid deenergized closure describe the family, but pressure, voltage and area suitability follow the actual suffix and body.

Manufacturer reference ↗

Features and benefits

  • Fail-closed operation isolates supply when electrical power is removed.

Manufacturer reference ↗

Published application context

  • Automatic gas/air shutoff

Manufacturer reference ↗

Technical facts in the product overview

  • DN: 40 to 250
  • pu: max. 230 mbar to max. 8 bar

Manufacturer reference ↗

Specifications

Fuel, Gas & Media Specifications

Gas Type
Natural Gas, Town Gas, LPG (gaseous), Biogas, Hydrogen, landfill gas, Clean Air

Storage/Transport Temperatures

Storage/Transport Temperature Range
-20 to +40 deg C

Standards & Certifications

Explosion Protection Marking
ATEX: II 2G Ex eb ob IIC T5 Gb; IECEx: Ex eb ob IIC T5 Gb
Explosion-Proof Versions
VK..X, VK..HX (Zone 1 and 2, ATEX and IECEx compliant)
Safety Class
Class 1
Approvals
CE (GAR, PED, EMC, LVD), UKCA, AGA, IECEx, ATEX, EAC

Dimensions & Weight

Maximum Installation Height
2000 m AMSL

Environmental Conditions

Ambient Temperature Range
VK, VK..H, VK..Z: -15 to +60 deg C; VK..X, VK..HX: -15 to +40 deg C
Enclosure Rating
IP54 (standard), IP65 (explosion-proof versions)

Installation & Mounting Specifications

Installation Orientation
Vertical upright or tilted (not upside down)

Connections & Interfaces

Electrical Connections
Plug (EN 175301-803), M20 cable gland, terminal (2.5 mm²)
Connection Type
Rp Internal Thread (ISO 7-1), Flange (ISO 7005, PN 16)

Electrical Specifications

Maintenance Interval
At least once a year; twice for biogas applications
Mains Voltage
24 VDC, 100 to 240 VAC, 50/60 Hz

Pressure Specifications

Inlet Pressure Range
Up to 8 bar depending on model

Material Specifications

Valve Body Material
Aluminum alloy (AlSi) or GGG 40 cast iron (flanged versions)

Actuation, Valve & Motion Control Specifications

Valve Plate Seal
Perbunan, Viton
Actuator Type
Hydraulically actuated, closed when de-energized
Opening Time
DN 40: 5 seconds; DN 50-65: 8 seconds; DN 80-100: 10 seconds; DN 125-200: 13 seconds; DN 250: -
Closing Time
<1 seconds

Dimensions & Size Specifications

Nominal Sizes
DN 40 to 250

Overview

Product Type
Motorized valve for gas

Processing & Performance Metrics

Duty Cycle
1

Technical Specifications

DN
40 to 250
pu
max. 230 mbar to max. 8 bar
Motorized valves for gas VK — manufacturer page values
ParameterPublished value / configuration
Gas TypeNatural Gas, Town Gas, LPG (gaseous), Biogas, Hydrogen, landfill gas, Clean Air
Storage/Transport Temperature Range-20 to +40 deg C
Explosion Protection MarkingATEX: II 2G Ex eb ob IIC T5 Gb; IECEx: Ex eb ob IIC T5 Gb
Explosion-Proof VersionsVK..X, VK..HX (Zone 1 and 2, ATEX and IECEx compliant)
Safety ClassClass 1
ApprovalsCE (GAR, PED, EMC, LVD), UKCA, AGA, IECEx, ATEX, EAC
Maximum Installation Height2000 m AMSL
Ambient Temperature RangeVK, VK..H, VK..Z: -15 to +60 deg C; VK..X, VK..HX: -15 to +40 deg C
Enclosure RatingIP54 (standard), IP65 (explosion-proof versions)
Installation OrientationVertical upright or tilted (not upside down)
Electrical ConnectionsPlug (EN 175301-803), M20 cable gland, terminal (2.5 mm²)
Connection TypeRp Internal Thread (ISO 7-1), Flange (ISO 7005, PN 16)
Maintenance IntervalAt least once a year; twice for biogas applications
Mains Voltage24 VDC, 100 to 240 VAC, 50/60 Hz
Inlet Pressure RangeUp to 8 bar depending on model
Valve Body MaterialAluminum alloy (AlSi) or GGG 40 cast iron (flanged versions)
Valve Plate SealPerbunan, Viton
Actuator TypeHydraulically actuated, closed when de-energized
Opening TimeDN 40: 5 seconds; DN 50-65: 8 seconds; DN 80-100: 10 seconds; DN 125-200: 13 seconds; DN 250: -
Closing Time<1 seconds
Nominal SizesDN 40 to 250
Product TypeMotorized valve for gas
Duty Cycle1
DN40 to 250
pumax. 230 mbar to max. 8 bar

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
KS03002234PLUG,THRD,PG 13.5Request quotation
KS03024176RING,RETN,RA9 DIN 6799Request quotation
KS03109003O-RING 210X4 FKM 70 SHORE GREENRequest quotation
KS03109006O-Ring 165x5 FKM 70 Shore grunRequest quotation
KS03109015O-RING 98X3 FKM 70 SHORE GREENRequest quotation
KS03109016O-RING 120X3 FKM 70 SHORE GREENRequest quotation
KS03109017O-RING 149X3 FKM 70 SHORE GREENRequest quotation
KS03109143O RING,DIA. 228MM X DIA. 4MM SECT,NITRILRequest quotation
KS03109183O-RING 165X5 NBR 70 SHORE BLACKRequest quotation
KS03109274O RING,98 X 3Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/fuel-and-air-delivery/shutoff-valves/motorized-valves-for-gas-vk

Last source check: 2026-11-02

Motrized valves for gas VK · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.