Direct Fired Furnace Burners
Wall Hugger Invisiflame WHI
WHI Wall Hugger Invisiflame uses a flat flame that stays near the furnace wall, allowing placement close to the load without flame impingement.
WHI Wall Hugger Invisiflame uses a flat flame that stays near the furnace wall, allowing placement close to the load without flame impingement. The family supports cold or preheated air, direct or pilot ignition and round or square tiles. Low-NOx and turndown figures are published with the burner-specific operating conditions.
Features & Benefits
- Minimum Furnace Temperature
- 1600 deg F (870 deg C) Invisiflame® Mode
- Installation Orientation
- Burner can be placed close to the load|Wall‑mounted
- Air Temperature Range
- Cold or preheated air up to 900 deg F (480 deg C)
- Excess Air Operation
- Low excess air operation: ~5%
- Combustion Principle
- Three‑stage air injection design; flame hugs the furnace wall
- Operating Modes
- Firing mode (visible flame) and Invisiflame® mode (flameless‑type operation)
- Flame Stability
- Stable operation on‑ratio, including in cold furnaces
- Flame Detection
- UV Scanner (flame detection in Firing mode only)
- Connection Type
- Single air and fuel connections
- Turndown Ratio
- 8:1 on-ratio
- Flame Behavior
- Flame hugs wall, suitable for close placement to load
- Combustion Air
- Cold or preheated air up to 900 deg F (480 deg C)
- Capacity Range
- 2 to 6 MMBtu/hr (580 to 1,760 kW), depending on air preheat
- NOx Emissions
- Ultra‑low NOx: 20 ppm or less
- Ignition Type
- Direct Spark or Pilot Ignition
- Flame Profile
- Flat flame throughout firing range, even heat distribution, no impingement
- Burner Family
- Wall Hugger Invisiflame® (WHI)
- Tile Options
- Available in round or square tile versions
- CO Emissions
- Low CO emissions, including during cold start
- Burner Type
- Wall‑hugging, flat‑flame gas burner
- Fuel Type
- Clean industrial fuel gas ≥ 500 Btu/ft³ (19.7 MJ/nm³)
- A wall-following flame avoids impingement while heating evenly.
Applications
- Wall-adjacent furnace heating without flame impingement
Detailed capabilities
Flame profile and construction choices
WHI retains a wall-following flat flame throughout the firing range to heat near the load without impingement. Round and square tiles, adjustable flange mounting and single air/fuel connections support the layout. Cold-start CO behavior, on-ratio turndown and the low-excess-air condition are separately described. Preheated-air and low-NOx figures retain their stated limits rather than defining all operating points.
Features and benefits
- A wall-following flame avoids impingement while heating evenly.
Published application context
- Wall-adjacent furnace heating without flame impingement
Combustion/Furnace/Chamber Temperatures
- Minimum Furnace Temperature
- 1600 deg F (870 deg C) Invisiflame® Mode
Installation & Mounting Specifications
- Installation Orientation
- Burner can be placed close to the load; Wall‑mounted
Air & Combustion Air Specifications
- Air Temperature Range
- Cold or preheated air up to 900 deg F (480 deg C)
- Excess Air Operation
- Low excess air operation: ~5%
Combustion, Mixing & Fuel Dynamics
- Combustion Principle
- Three‑stage air injection design; flame hugs the furnace wall
Control, Logic & System Behavior
- Operating Modes
- Firing mode (visible flame) and Invisiflame® mode (flameless‑type operation)
Ignition, Flame & Supervision Specifications
- Flame Stability
- Stable operation on‑ratio, including in cold furnaces
- Flame Detection
- UV Scanner (flame detection in Firing mode only)
- Flame Behavior
- Flame hugs wall, suitable for close placement to load
- Ignition Type
- Direct Spark or Pilot Ignition
- Flame Profile
- Flat flame throughout firing range, even heat distribution, no impingement
Connections & Interfaces
- Connection Type
- Single air and fuel connections
Performance, Flow & Capacity
- Turndown Ratio
- 8:1 on-ratio
Combustion Air, Blower & Emissions Specifications
- Combustion Air
- Cold or preheated air up to 900 deg F (480 deg C)
Processing & Performance Metrics
- Capacity Range
- 2 to 6 MMBtu/hr (580 to 1,760 kW), depending on air preheat
- NOx Emissions
- Ultra‑low NOx: 20 ppm or less
- CO Emissions
- Low CO emissions, including during cold start
Product Design & Configuration
- Burner Family
- Wall Hugger Invisiflame® (WHI)
Mechanical Design, Layout & Construction Options
- Tile Options
- Available in round or square tile versions
Applications & Compatibility
- Applications
- Furnaces requiring uniform heating, wall‑mounted burners, low NOx, and no flame impingement
Overview
- Burner Type
- Wall‑hugging, flat‑flame gas burner
Fuel, Gas & Media Specifications
- Fuel Type
- Clean industrial fuel gas ≥ 500 Btu/ft³ (19.7 MJ/nm³)
| Parameter | Published value / configuration |
|---|---|
| Minimum Furnace Temperature | 1600 deg F (870 deg C) Invisiflame® Mode |
| Installation Orientation | Burner can be placed close to the load; Wall‑mounted |
| Air Temperature Range | Cold or preheated air up to 900 deg F (480 deg C) |
| Excess Air Operation | Low excess air operation: ~5% |
| Combustion Principle | Three‑stage air injection design; flame hugs the furnace wall |
| Operating Modes | Firing mode (visible flame) and Invisiflame® mode (flameless‑type operation) |
| Flame Stability | Stable operation on‑ratio, including in cold furnaces |
| Flame Detection | UV Scanner (flame detection in Firing mode only) |
| Flame Behavior | Flame hugs wall, suitable for close placement to load |
| Ignition Type | Direct Spark or Pilot Ignition |
| Flame Profile | Flat flame throughout firing range, even heat distribution, no impingement |
| Connection Type | Single air and fuel connections |
| Turndown Ratio | 8:1 on-ratio |
| Combustion Air | Cold or preheated air up to 900 deg F (480 deg C) |
| Capacity Range | 2 to 6 MMBtu/hr (580 to 1,760 kW), depending on air preheat |
| NOx Emissions | Ultra‑low NOx: 20 ppm or less |
| CO Emissions | Low CO emissions, including during cold start |
| Burner Family | Wall Hugger Invisiflame® (WHI) |
| Tile Options | Available in round or square tile versions |
| Applications | Furnaces requiring uniform heating, wall‑mounted burners, low NOx, and no flame impingement |
| Burner Type | Wall‑hugging, flat‑flame gas burner |
| Fuel Type | Clean industrial fuel gas ≥ 500 Btu/ft³ (19.7 MJ/nm³) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| HK302844 | CPLG,FLX,3/8 DIA X 3/8 SQ MATHIS ENERGY | Request quotation |
| HK404618 | BDY ASSY,WHI260 OUTR | Request quotation |
| HK404619 | BDY ASSY,WHI260 INR | Request quotation |
| HK404620 | NZL ASSY,WHI260 SPIN RACK | Request quotation |
| HK404622 | TB ASSY,WHI260 BRNR GAS | Request quotation |
| HK404623 | GSKT,WHI260 BRNR UNIT MTG KAOWOOL,1/8 TH | Request quotation |
| HK404624 | GSKT,WHI260 INR BDY MTG KAOWOOL,1/8 THK, | Request quotation |
| HK404625 | GSKT,WHI260 BKPLT MTG KAOWOOL,1/8 THK,23 | Request quotation |
| HK404626 | NZL,WHI260 BRNR AIR/GAS RFRCT | Request quotation |
| HK404627 | INSLN,WHI260 BRNR BKPLT CRMC FBR 2300F,3 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Wall Hugger Invisiflame Low Nox Flat Flame Gas Burner · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.