Honeywell Process Measurement & Control

Direct Fired Furnace Burners

Wall Hugger Invisiflame WHI

WHI Wall Hugger Invisiflame uses a flat flame that stays near the furnace wall, allowing placement close to the load without flame impingement.

WHI Wall Hugger Invisiflame uses a flat flame that stays near the furnace wall, allowing placement close to the load without flame impingement. The family supports cold or preheated air, direct or pilot ignition and round or square tiles. Low-NOx and turndown figures are published with the burner-specific operating conditions.

Features & Benefits

Minimum Furnace Temperature
1600 deg F (870 deg C) Invisiflame® Mode
Installation Orientation
Burner can be placed close to the load|Wall‑mounted
Air Temperature Range
Cold or preheated air up to 900 deg F (480 deg C)
Excess Air Operation
Low excess air operation: ~5%
Combustion Principle
Three‑stage air injection design; flame hugs the furnace wall
Operating Modes
Firing mode (visible flame) and Invisiflame® mode (flameless‑type operation)
Flame Stability
Stable operation on‑ratio, including in cold furnaces
Flame Detection
UV Scanner (flame detection in Firing mode only)
Connection Type
Single air and fuel connections
Turndown Ratio
8:1 on-ratio
Flame Behavior
Flame hugs wall, suitable for close placement to load
Combustion Air
Cold or preheated air up to 900 deg F (480 deg C)
Capacity Range
2 to 6 MMBtu/hr (580 to 1,760 kW), depending on air preheat
NOx Emissions
Ultra‑low NOx: 20 ppm or less
Ignition Type
Direct Spark or Pilot Ignition
Flame Profile
Flat flame throughout firing range, even heat distribution, no impingement
Burner Family
Wall Hugger Invisiflame® (WHI)
Tile Options
Available in round or square tile versions
CO Emissions
Low CO emissions, including during cold start
Burner Type
Wall‑hugging, flat‑flame gas burner
Fuel Type
Clean industrial fuel gas ≥ 500 Btu/ft³ (19.7 MJ/nm³)
  • A wall-following flame avoids impingement while heating evenly.

Applications

  • Wall-adjacent furnace heating without flame impingement

Detailed capabilities

Flame profile and construction choices

WHI retains a wall-following flat flame throughout the firing range to heat near the load without impingement. Round and square tiles, adjustable flange mounting and single air/fuel connections support the layout. Cold-start CO behavior, on-ratio turndown and the low-excess-air condition are separately described. Preheated-air and low-NOx figures retain their stated limits rather than defining all operating points.

Manufacturer reference ↗

Features and benefits

  • A wall-following flame avoids impingement while heating evenly.

Manufacturer reference ↗

Published application context

  • Wall-adjacent furnace heating without flame impingement

Manufacturer reference ↗

Specifications

Combustion/Furnace/Chamber Temperatures

Minimum Furnace Temperature
1600 deg F (870 deg C) Invisiflame® Mode

Installation & Mounting Specifications

Installation Orientation
Burner can be placed close to the load; Wall‑mounted

Air & Combustion Air Specifications

Air Temperature Range
Cold or preheated air up to 900 deg F (480 deg C)
Excess Air Operation
Low excess air operation: ~5%

Combustion, Mixing & Fuel Dynamics

Combustion Principle
Three‑stage air injection design; flame hugs the furnace wall

Control, Logic & System Behavior

Operating Modes
Firing mode (visible flame) and Invisiflame® mode (flameless‑type operation)

Ignition, Flame & Supervision Specifications

Flame Stability
Stable operation on‑ratio, including in cold furnaces
Flame Detection
UV Scanner (flame detection in Firing mode only)
Flame Behavior
Flame hugs wall, suitable for close placement to load
Ignition Type
Direct Spark or Pilot Ignition
Flame Profile
Flat flame throughout firing range, even heat distribution, no impingement

Connections & Interfaces

Connection Type
Single air and fuel connections

Performance, Flow & Capacity

Turndown Ratio
8:1 on-ratio

Combustion Air, Blower & Emissions Specifications

Combustion Air
Cold or preheated air up to 900 deg F (480 deg C)

Processing & Performance Metrics

Capacity Range
2 to 6 MMBtu/hr (580 to 1,760 kW), depending on air preheat
NOx Emissions
Ultra‑low NOx: 20 ppm or less
CO Emissions
Low CO emissions, including during cold start

Product Design & Configuration

Burner Family
Wall Hugger Invisiflame® (WHI)

Mechanical Design, Layout & Construction Options

Tile Options
Available in round or square tile versions

Applications & Compatibility

Applications
Furnaces requiring uniform heating, wall‑mounted burners, low NOx, and no flame impingement

Overview

Burner Type
Wall‑hugging, flat‑flame gas burner

Fuel, Gas & Media Specifications

Fuel Type
Clean industrial fuel gas ≥ 500 Btu/ft³ (19.7 MJ/nm³)
Wall Hugger Invisiflame WHI — manufacturer page values
ParameterPublished value / configuration
Minimum Furnace Temperature1600 deg F (870 deg C) Invisiflame® Mode
Installation OrientationBurner can be placed close to the load; Wall‑mounted
Air Temperature RangeCold or preheated air up to 900 deg F (480 deg C)
Excess Air OperationLow excess air operation: ~5%
Combustion PrincipleThree‑stage air injection design; flame hugs the furnace wall
Operating ModesFiring mode (visible flame) and Invisiflame® mode (flameless‑type operation)
Flame StabilityStable operation on‑ratio, including in cold furnaces
Flame DetectionUV Scanner (flame detection in Firing mode only)
Flame BehaviorFlame hugs wall, suitable for close placement to load
Ignition TypeDirect Spark or Pilot Ignition
Flame ProfileFlat flame throughout firing range, even heat distribution, no impingement
Connection TypeSingle air and fuel connections
Turndown Ratio8:1 on-ratio
Combustion AirCold or preheated air up to 900 deg F (480 deg C)
Capacity Range2 to 6 MMBtu/hr (580 to 1,760 kW), depending on air preheat
NOx EmissionsUltra‑low NOx: 20 ppm or less
CO EmissionsLow CO emissions, including during cold start
Burner FamilyWall Hugger Invisiflame® (WHI)
Tile OptionsAvailable in round or square tile versions
ApplicationsFurnaces requiring uniform heating, wall‑mounted burners, low NOx, and no flame impingement
Burner TypeWall‑hugging, flat‑flame gas burner
Fuel TypeClean industrial fuel gas ≥ 500 Btu/ft³ (19.7 MJ/nm³)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
HK302844CPLG,FLX,3/8 DIA X 3/8 SQ MATHIS ENERGYRequest quotation
HK404618BDY ASSY,WHI260 OUTRRequest quotation
HK404619BDY ASSY,WHI260 INRRequest quotation
HK404620NZL ASSY,WHI260 SPIN RACKRequest quotation
HK404622TB ASSY,WHI260 BRNR GASRequest quotation
HK404623GSKT,WHI260 BRNR UNIT MTG KAOWOOL,1/8 THRequest quotation
HK404624GSKT,WHI260 INR BDY MTG KAOWOOL,1/8 THK,Request quotation
HK404625GSKT,WHI260 BKPLT MTG KAOWOOL,1/8 THK,23Request quotation
HK404626NZL,WHI260 BRNR AIR/GAS RFRCTRequest quotation
HK404627INSLN,WHI260 BRNR BKPLT CRMC FBR 2300F,3Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/direct-fired-furnace-burners/wall-hugger-invisiflame-whi

Last source check: 2026-11-02

Wall Hugger Invisiflame Low Nox Flat Flame Gas Burner · Manufacturer ownership retained; republication licence not independently confirmed