Direct Fired Furnace Burners
BIC, BICA, ZIC
BIC, BICA and ZIC connect to ceramic burner tubes and differ in housing material: cast steel, aluminum and sheet steel.
BIC, BICA and ZIC connect to ceramic burner tubes and differ in housing material: cast steel, aluminum and sheet steel. The family covers cold-air, hot-air, flat-flame and high-temperature duties. Fuel options include conventional gases, while biological methane and low-calorific gases require consultation; insulated housings and ignition lances are available.
Features & Benefits
- Maximum Furnace Temperature
- Up to 1450 deg C (2642 deg F)
- Ambient Temperature Range
- -20 to +180°C (-4 to +356°F)
- Installation Orientation
- Horizontal or angled
- Air Preheat Capability
- Up to 600 deg C (1112 deg F)
- Ceramic Tube Material
- SiSiC (Silicon Infiltrated Silicon Carbide)
- Visible Flame Length
- 22 to 200 cm depending on model
- Combustion Principle
- Nozzle‑mixing
- Flame Supervision
- Flame rod standard; UV sensor optional
- Outlet Velocity
- Medium to high (up to 155 m/s)
- Capacity Range
- BIC: 15 to 1000 kW|BICA: 15 to 70 kW|ZIC: 315 to 1000 kW
- Ignition Type
- Direct spark, integrated torch
- Control Type
- On/Off, modulating, pilot rate, pneumatic ratio control
- Fuel Type
- BIC: Natural gas, LPG, coke oven gas, town gas, biogas, low‑CV gas|BICA: Natural gas, LPG|ZIC: Natural gas, LPG, coke oven gas, town gas, biogas, low‑CV gas
- Approvals
- Eurasian Customs Union (Meets technical specifications), EN 746-2, REACH Regulation (Applies to BICW/ZICW (contains RCF/ASW insulation)), WEEE Directive Disposal Compliance, Machinery Directive 2006/42/EC
- Material
- BIC: Cast Steel|BICA: AlSi|BICW/ZICW: Steel + insulation|ZIC: Steel
- Burner sizes
- 50 to 200
- Capacity
- 10 to 1000 kW
- Burner length
- 300 to 1200 mm
Applications
- Cold-air and hot-air furnace heating
- Flat-flame and high-temperature firing
Detailed capabilities
Housing, fuel and burner-tube selections
BIC uses cast steel, BICA aluminum and ZIC sheet steel, all with ceramic-tube connection. Threaded gas connections and burner lengths are selected around the furnace. Integrated ignition lances and internal insulation are optional configurations. The source lists conventional gases directly but requires consultation for biological methane and low-calorific fuels; those fuels are not unconditional approvals for every standard burner.
Published application context
- Cold-air and hot-air furnace heating
- Flat-flame and high-temperature firing
Technical facts in the product overview
- Burner sizes: 50 to 200
- Capacity: 10 to 1000 kW
- Burner length: 300 to 1200 mm
Overview
- Models
- BIC, BICA, BICW, ZIC, ZICW
Maximum/Minimum Temperature Limits
- Maximum Furnace Temperature
- Up to 1450 deg C (2642 deg F)
Environmental Conditions
- Ambient Temperature Range
- -20 to +180°C (-4 to +356°F)
Installation & Mounting Specifications
- Installation Orientation
- Horizontal or angled
Air & Combustion Air Specifications
- Air Preheat Capability
- Up to 600 deg C (1112 deg F)
Material Specifications
- Ceramic Tube Material
- SiSiC (Silicon Infiltrated Silicon Carbide)
- Material
- BIC: Cast Steel; BICA: AlSi; BICW/ZICW: Steel + insulation; ZIC: Steel
Burner/Flame‑Related Lengths
- Visible Flame Length
- 22 to 200 cm depending on model
Combustion, Mixing & Fuel Dynamics
- Combustion Principle
- Nozzle‑mixing
Ignition, Flame & Supervision Specifications
- Flame Supervision
- Flame rod standard; UV sensor optional
- Ignition Type
- Direct spark, integrated torch
Processing & Performance Metrics
- Outlet Velocity
- Medium to high (up to 155 m/s)
- Capacity Range
- BIC: 15 to 1000 kW; BICA: 15 to 70 kW; ZIC: 315 to 1000 kW
Control, Logic & Functional Behavior
- Control Type
- On/Off, modulating, pilot rate, pneumatic ratio control
Fuel, Gas & Media Specifications
- Fuel Type
- BIC: Natural gas, LPG, coke oven gas, town gas, biogas, low‑CV gas; BICA: Natural gas, LPG; ZIC: Natural gas, LPG, coke oven gas, town gas, biogas, low‑CV gas
Standards & Certifications
- Approvals
- Eurasian Customs Union (Meets technical specifications), EN 746-2, REACH Regulation (Applies to BICW/ZICW (contains RCF/ASW insulation)), WEEE Directive Disposal Compliance, Machinery Directive 2006/42/EC
Technical Specifications
- Burner sizes
- 50 to 200
- Capacity
- 10 to 1000 kW
- Burner length
- 300 to 1200 mm
| Parameter | Published value / configuration |
|---|---|
| Models | BIC, BICA, BICW, ZIC, ZICW |
| Maximum Furnace Temperature | Up to 1450 deg C (2642 deg F) |
| Ambient Temperature Range | -20 to +180°C (-4 to +356°F) |
| Installation Orientation | Horizontal or angled |
| Air Preheat Capability | Up to 600 deg C (1112 deg F) |
| Ceramic Tube Material | SiSiC (Silicon Infiltrated Silicon Carbide) |
| Material | BIC: Cast Steel; BICA: AlSi; BICW/ZICW: Steel + insulation; ZIC: Steel |
| Visible Flame Length | 22 to 200 cm depending on model |
| Combustion Principle | Nozzle‑mixing |
| Flame Supervision | Flame rod standard; UV sensor optional |
| Ignition Type | Direct spark, integrated torch |
| Outlet Velocity | Medium to high (up to 155 m/s) |
| Capacity Range | BIC: 15 to 1000 kW; BICA: 15 to 70 kW; ZIC: 315 to 1000 kW |
| Control Type | On/Off, modulating, pilot rate, pneumatic ratio control |
| Fuel Type | BIC: Natural gas, LPG, coke oven gas, town gas, biogas, low‑CV gas; BICA: Natural gas, LPG; ZIC: Natural gas, LPG, coke oven gas, town gas, biogas, low‑CV gas |
| Approvals | Eurasian Customs Union (Meets technical specifications), EN 746-2, REACH Regulation (Applies to BICW/ZICW (contains RCF/ASW insulation)), WEEE Directive Disposal Compliance, Machinery Directive 2006/42/EC |
| Burner sizes | 50 to 200 |
| Capacity | 10 to 1000 kW |
| Burner length | 300 to 1200 mm |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| HK2966 | GSKT,8 RPM FLG KLNGR,1/8 THK,750°F 95070 | Request quotation |
| HK2967A | GSKT,10 FLG KLNGR,1/8 THK,750°F 95070 | Request quotation |
| HK401313 | GSKT,8 ANSI GAS INLT KLNGR,1/8 THK,750°F | Request quotation |
| HK406865-D | GSKT,GAS TB BB 1106 3110 KLNGR,1/8 THK,7 | Request quotation |
| HK406917-B | GSKT,GAS TB BB 1112 3114 KLNGR,1/8 THK,7 | Request quotation |
| HK44307 | GSKT,BBC OIL TB BKPLT KLNGR,1/8 THK,750° | Request quotation |
| HK52994 | GSKT,BBX114/X118 GAS TB KLNGR,1/8 THK,75 | Request quotation |
| HK53032 | GSKT,BBX1112 GAS TB KLNGR,1/8 THK,750°F | Request quotation |
| HK55274 | GSKT,BBG2106 BRNR MTG KLNGR,1/8 THK,750° | Request quotation |
| HK70022 | GSKT,6 RPM KLNGR,1/8 THK,750°F 95070 | Request quotation |