Honeywell Process Measurement & Control

Direct Fired Furnace Burners

Beta BBG/BBC

Beta burners distinguish gas-only BBG from combination-fuel BBC designs.

Beta burners distinguish gas-only BBG from combination-fuel BBC designs. Both use rugged steel construction, low inlet-pressure requirements and broad air/fuel operating flexibility. BBC adds liquid-fuel atomization arrangements and pressure-or-suction applications. Tile choice, flame sensing, ignition method and preheated-air capability remain tied to the selected burner configuration.

Features & Benefits

Application Temperature Limit
Alloy tile: 1800 deg F (980 deg C)|Refractory tile: 2800 deg F (1540 deg C)
Air Supply Requirement
Nominal 16 osig (68.9 mbar)
Air Preheat Capability
Up to 900 deg F (480 deg C)
Minimum Heating Value
>500 Btu/scf (19.7 MJ/nm³
Gas Supply Pressure
4 osig (17.2 mbar)
Flame Supervision
BBC Multi-Fuel Beta Burner: UV flame supervision|BBG Gas Beta Burner:UV (all models), ionization (BBG1_04-1_12)
Turndown Ratio
BBC Multi-Fuel Beta Burner: Varies with fuel type, higher with excess air|BBG Gas Beta Burner; Approximately 10:1 (higher with excess air)
Capacity Range
BBC Multi-Fuel Beta Burner - 2.9 to 109 million Btu/hr (760 to 28,920 kW)|BBG Gas Beta Burner - 3.1 to 123 million Btu/hr (820 to 32,520 kW)
Ignition Type
BBC Multi-Fuel Beta Burner: Pilot ignition|BBG Gas Beta Burner: Direct spark (BBG_204-212), pilot ignition
Tile Options
Alloy or refractory, converging/diverging
Burner Type
BBC Multi-Fuel Beta Burner - Gas‑only high‑input industrial burner|BBG Gas Beta Burner - Multi‑fuel combination industrial burner
Fuel Type
BBC Multi-Fuel Beta Burner - Clean industrial fuel gas, light oil, liquid propane, heavy fuel oils|BBG Gas Beta Burner -Clean industrial fuel gas
Approvals
BBG Gas Beta Burner - Compliance EN 762-2 (2010) and EN ISO 12100 (2010)
BBC fuel requirement
any clean industrial fuel with a higher heating value of 500 BTU/scf (19.7 MJ/nm³)
  • Low air and fuel pressure requirements broaden installation flexibility.

Applications

  • Thermal-fluid heating
  • Oxidizers
  • Rotary kilns
  • Gypsum kettles
  • Air heaters
  • Incinerators

Detailed capabilities

Gas-only and combination-fuel arrangements

BBG addresses gas-only high-input firing, with direct-spark or pilot ignition and UV or ionization supervision. BBC extends the family to combination-fuel duty, using pilot ignition and UV supervision. Both offer alloy or refractory tiles and insulated configurations for preheated air up to 480°C. Their common capacity envelope does not make all fuel, ignition and sensing arrangements interchangeable.

Manufacturer reference ↗

BBC atomization and process flexibility

BBC accepts the stated clean industrial gases above the minimum heating value and supports liquid-fuel configurations. Low-pressure atomization addresses light oil or liquid propane; compressed-air atomization is offered for heavier oils or high-altitude installations. Pressure and suction process environments are described. Turndown depends on fuel and excess air, and the applications include fluid heaters, oxidizers, kilns, gypsum kettles, air heaters and incinerators.

Manufacturer reference ↗

Features and benefits

  • Low air and fuel pressure requirements broaden installation flexibility.

Manufacturer reference ↗

Published application context

  • Thermal-fluid heating
  • Oxidizers
  • Rotary kilns
  • Gypsum kettles
  • Air heaters
  • Incinerators

Manufacturer reference ↗

Technical facts in the product overview

  • BBC fuel requirement: any clean industrial fuel with a higher heating value of 500 BTU/scf (19.7 MJ/nm³)

Manufacturer reference ↗

Specifications

Maximum/Minimum Temperature Limits

Application Temperature Limit
Alloy tile: 1800 deg F (980 deg C); Refractory tile: 2800 deg F (1540 deg C)

Air & Combustion Air Specifications

Air Supply Requirement
Nominal 16 osig (68.9 mbar)
Air Preheat Capability
Up to 900 deg F (480 deg C)

Combustion, Mixing & Fuel Dynamics

Minimum Heating Value
>500 Btu/scf (19.7 MJ/nm³

Pressure Specifications

Gas Supply Pressure
4 osig (17.2 mbar)

Ignition, Flame & Supervision Specifications

Flame Supervision
BBC Multi-Fuel Beta Burner: UV flame supervision; BBG Gas Beta Burner:UV (all models), ionization (BBG1_04-1_12)
Ignition Type
BBC Multi-Fuel Beta Burner: Pilot ignition; BBG Gas Beta Burner: Direct spark (BBG_204-212), pilot ignition

Performance, Flow & Capacity

Turndown Ratio
BBC Multi-Fuel Beta Burner: Varies with fuel type, higher with excess air; BBG Gas Beta Burner; Approximately 10:1 (higher with excess air)

Processing & Performance Metrics

Capacity Range
BBC Multi-Fuel Beta Burner - 2.9 to 109 million Btu/hr (760 to 28,920 kW); BBG Gas Beta Burner - 3.1 to 123 million Btu/hr (820 to 32,520 kW)

Mechanical Design, Layout & Construction Options

Tile Options
Alloy or refractory, converging/diverging

Overview

Burner Type
BBC Multi-Fuel Beta Burner - Gas‑only high‑input industrial burner; BBG Gas Beta Burner - Multi‑fuel combination industrial burner

Fuel, Gas & Media Specifications

Fuel Type
BBC Multi-Fuel Beta Burner - Clean industrial fuel gas, light oil, liquid propane, heavy fuel oils; BBG Gas Beta Burner -Clean industrial fuel gas

Standards & Certifications

Approvals
BBG Gas Beta Burner - Compliance EN 762-2 (2010) and EN ISO 12100 (2010)

Technical Specifications

BBC fuel requirement
any clean industrial fuel with a higher heating value of 500 BTU/scf (19.7 MJ/nm³)
Beta BBG/BBC — manufacturer page values
ParameterPublished value / configuration
Application Temperature LimitAlloy tile: 1800 deg F (980 deg C); Refractory tile: 2800 deg F (1540 deg C)
Air Supply RequirementNominal 16 osig (68.9 mbar)
Air Preheat CapabilityUp to 900 deg F (480 deg C)
Minimum Heating Value>500 Btu/scf (19.7 MJ/nm³
Gas Supply Pressure4 osig (17.2 mbar)
Flame SupervisionBBC Multi-Fuel Beta Burner: UV flame supervision; BBG Gas Beta Burner:UV (all models), ionization (BBG1_04-1_12)
Ignition TypeBBC Multi-Fuel Beta Burner: Pilot ignition; BBG Gas Beta Burner: Direct spark (BBG_204-212), pilot ignition
Turndown RatioBBC Multi-Fuel Beta Burner: Varies with fuel type, higher with excess air; BBG Gas Beta Burner; Approximately 10:1 (higher with excess air)
Capacity RangeBBC Multi-Fuel Beta Burner - 2.9 to 109 million Btu/hr (760 to 28,920 kW); BBG Gas Beta Burner - 3.1 to 123 million Btu/hr (820 to 32,520 kW)
Tile OptionsAlloy or refractory, converging/diverging
Burner TypeBBC Multi-Fuel Beta Burner - Gas‑only high‑input industrial burner; BBG Gas Beta Burner - Multi‑fuel combination industrial burner
Fuel TypeBBC Multi-Fuel Beta Burner - Clean industrial fuel gas, light oil, liquid propane, heavy fuel oils; BBG Gas Beta Burner -Clean industrial fuel gas
ApprovalsBBG Gas Beta Burner - Compliance EN 762-2 (2010) and EN ISO 12100 (2010)
BBC fuel requirementany clean industrial fuel with a higher heating value of 500 BTU/scf (19.7 MJ/nm³)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
101028407KIT,LIT,BBC/BBG,BETA GAS OIL BURNERSRequest quotation
101028408KIT,LIT,BBG,BETA GAS BURNERSRequest quotation
1121BUBSHG,1.5 IN. X 1 IN.,NPT,MIRequest quotation
802003322Burner, BBG10-2NNGS0P9XXG0NPCWURequest quotation
802003323Burner, BBG18-2NNGS0P9XXXXNPCWURequest quotation
802003324Burner, BBG08-2NNGS0P9XXG0NPCWURequest quotation
802003358BBG18 2NNGS3P0XXXXNPCWU burnerRequest quotation
802003428BBC08-2NLOS0P9A0G0NPCWURequest quotation
802003499BBG18 2NNGS6P9XXXXNPCWURequest quotation
802003759HK-MAX 2M545-SB/R-(33)BRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/direct-fired-furnace-burners/beta-bbg-bbc

Last source check: 2026-11-02