Direct Fired Furnace Burners
TriOx Burner
TriOx uses three-stage air injection for high-temperature processes including aluminum furnaces, steel reheating and thermal-fluid heaters.
TriOx uses three-stage air injection for high-temperature processes including aluminum furnaces, steel reheating and thermal-fluid heaters. The arrangement targets low NOx and CO while reducing scale or dross in the cited metal applications. It accepts qualified industrial fuel gases with ambient or preheated air and offers several operating modes.
Features & Benefits
- Operating Temperature Range
- >1600°F (870°C)
- Air Supply Pressure Range
- 13.9 in wc (35 mbar)
- Design Optimization Tool
- FLUENT® Computational Fluid Dynamics (CFD) software
- Air Temperature Options
- Ambient Air, Preheated Air
- Performance Benefits
- Reduced metal loss, scale/dross reduction, visible flame in Invisiflame® mode
- Excess Air Operation
- 5% (low excess air for fuel efficiency)
- Gas Supply Pressure
- ≤ 20 in w.c. (50 mbar)
- Flame Supervision
- 1/2 in UV Scanner Port, 3/4 in UV Scanner Port, None
- Connection Type
- Single air and single low-pressure gas connection
- Air Inlet Sizes
- 6 in, 8 in, 12 in, 14 in, 16 in
- Capacity Range
- 4.2 to >27 MM Btu/hr (1230 to 7910 kW)
- NOx Emissions
- ≤ 20 ppm
- Ignition Type
- Direct Spark, IPG Pilot, ZMI Pilot, None
- CO Emissions
- Low, including on cold start
- CFD Modeling
- Burner design optimized using FLUENT® CFD software
- Firing Mode
- Standard, Invisiflame®, Switching between modes
- Fuel Type
- Clean industrial fuel gas ≥ 500 Btu/ft³ (19.7 MJ/nm³)
- Staged injection reduces scale or dross in the cited metal applications.
- Low excess-air operation supports fuel efficiency.
Applications
- Aluminum furnaces
- Steel reheating furnaces
- Thermal-fluid heaters
Detailed capabilities
Staged air and available operating modes
TriOx divides combustion air into three stages to manage NOx and CO while improving the heating process. Standard, switching and Invisiflame-only modes provide different operating arrangements, with direct-spark or pilot ignition. Low excess air supports efficiency, and the source associates the staging with reduced scale/dross in steel and aluminum. The fuel must meet the stated minimum heating value; air may be ambient or preheated as configured.
Features and benefits
- Staged injection reduces scale or dross in the cited metal applications.
- Low excess-air operation supports fuel efficiency.
Published application context
- Aluminum furnaces
- Steel reheating furnaces
- Thermal-fluid heaters
Overview
- Models
- TriOx 1000, 2000, 3000, 4000 Series
Operating/Process Temperature Ranges
- Operating Temperature Range
- >1600°F (870°C)
Air & Combustion Air Specifications
- Air Supply Pressure Range
- 13.9 in wc (35 mbar)
- Air Temperature Options
- Ambient Air, Preheated Air
- Excess Air Operation
- 5% (low excess air for fuel efficiency)
- Air Inlet Sizes
- 6 in, 8 in, 12 in, 14 in, 16 in
Product Configuration & Options
- Design Optimization Tool
- FLUENT® Computational Fluid Dynamics (CFD) software
- CFD Modeling
- Burner design optimized using FLUENT® CFD software
Performance Specifications
- Performance Benefits
- Reduced metal loss, scale/dross reduction, visible flame in Invisiflame® mode
Pressure Specifications
- Gas Supply Pressure
- ≤ 20 in w.c. (50 mbar)
Ignition, Flame & Supervision Specifications
- Flame Supervision
- 1/2 in UV Scanner Port, 3/4 in UV Scanner Port, None
- Ignition Type
- Direct Spark, IPG Pilot, ZMI Pilot, None
- Firing Mode
- Standard, Invisiflame®, Switching between modes
Connections & Interfaces
- Connection Type
- Single air and single low-pressure gas connection
Processing & Performance Metrics
- Capacity Range
- 4.2 to >27 MM Btu/hr (1230 to 7910 kW)
- NOx Emissions
- ≤ 20 ppm
- CO Emissions
- Low, including on cold start
Applications & Compatibility
- Applications
- Aluminum furnaces, steel reheat furnaces, thermal fluid heaters
Fuel, Gas & Media Specifications
- Fuel Type
- Clean industrial fuel gas ≥ 500 Btu/ft³ (19.7 MJ/nm³)
| Parameter | Published value / configuration |
|---|---|
| Models | TriOx 1000, 2000, 3000, 4000 Series |
| Operating Temperature Range | >1600°F (870°C) |
| Air Supply Pressure Range | 13.9 in wc (35 mbar) |
| Air Temperature Options | Ambient Air, Preheated Air |
| Excess Air Operation | 5% (low excess air for fuel efficiency) |
| Air Inlet Sizes | 6 in, 8 in, 12 in, 14 in, 16 in |
| Design Optimization Tool | FLUENT® Computational Fluid Dynamics (CFD) software |
| CFD Modeling | Burner design optimized using FLUENT® CFD software |
| Performance Benefits | Reduced metal loss, scale/dross reduction, visible flame in Invisiflame® mode |
| Gas Supply Pressure | ≤ 20 in w.c. (50 mbar) |
| Flame Supervision | 1/2 in UV Scanner Port, 3/4 in UV Scanner Port, None |
| Ignition Type | Direct Spark, IPG Pilot, ZMI Pilot, None |
| Firing Mode | Standard, Invisiflame®, Switching between modes |
| Connection Type | Single air and single low-pressure gas connection |
| Capacity Range | 4.2 to >27 MM Btu/hr (1230 to 7910 kW) |
| NOx Emissions | ≤ 20 ppm |
| CO Emissions | Low, including on cold start |
| Applications | Aluminum furnaces, steel reheat furnaces, thermal fluid heaters |
| Fuel Type | Clean industrial fuel gas ≥ 500 Btu/ft³ (19.7 MJ/nm³) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 101028461 | KIT,LIT,TRIPLE AIR STAGED ULTRA LO NOX B | Request quotation |
| HK10862 | BRNG ASSY,ADJ LVR | Request quotation |
| HK1781 | LVR,RLA HVY DUTY ADJ 96242 12FT 24PCS | Request quotation |
| HK200071X72.000 | PKG,1/4DIA BRDD ROPE X 72 L | Request quotation |
| HK20094 | BRNG,ROD END HEIM HF6C OR EQ NTNL ROD EN | Request quotation |
| HK300604 | FLG,WN,3,150 W/GASKET | Request quotation |
| HK300605 | FLG,WN,4,150 W/GASKET | Request quotation |
| HK401814 | INSLN INS,TRIOX2008 BRNR BKPLT CRMC FBR | Request quotation |
| HK401816 | INSLN INS,TRIOX2008 AIR INLT CRMC FBR 23 | Request quotation |
| HK401850 | TB ASSY,TRIOX1008 2008 AIR SEPARATING | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Triple Air Staged Ultra Low Nox Burner · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.