Direct Fired Furnace Burners
ThermJet
ThermJet creates a high-velocity hot-gas stream for load penetration and temperature uniformity in direct-fired processes.
ThermJet creates a high-velocity hot-gas stream for load penetration and temperature uniformity in direct-fired processes. Integrated orifices and rotatable inlet connections simplify setup. Fourteen sizes, preheated-air versions, fuel choices and flame-sensing options support different installations, while pulse, excess-air or stoichiometric control can be selected for the application.
Features & Benefits
- Maximum Combustion Air Temperature
- TJ: 300 deg F (149 deg C)|TJPCA: up to 1000 deg F (538 deg C)
- Process Temperature Range
- 2800 deg F (1540 deg C)
- Gas and Air Connections
- Adjustable in 90 deg increments
- Pipe Connection Type
- NPT, BSP, Flanged, Welded
- Combustor Materials
- Alloy, Silicon Carbide, Refractory, Down-firing block
- Flame Supervision
- UV Scanner (all models); Flame rod (TJ0015-TJ0100 only)
- Mounting Options
- Horizontal, vertical up/down
- Turndown Ratio
- Up to 50:1
- Flame Velocity
- High Velocity: up to 630 ft/s (192 m/s)|Medium Velocity: up to 750 ft/s (230 m/s)
- Capacity Range
- 150,000 to 20,000,000 BTU/h (40 to 5333 kW)
- NOx Emissions
- Low NOx; emissions vary by fuel, air temp, and firing rate
- Ignition Type
- Direct spark ignition; low fire start recommended
- Flame Length
- 9 to 216 in (229 to 5486 mm) depending on model and fuel
- Control Type
- Modulating, High/Low, Pulse firing, Fixed-air
- Burner Sizes
- 14 sizes (TJ/TJPCA0015 through TJ/TJPCA2000)
- Burner Type
- High‑velocity/medium‑velocity nozzle‑mix industrial gas burner
- Fuel Type
- Natural Gas, Propane, Butane
- Approvals
- Declaration of Incorporation confirmed, Eurasian Customs Union (Meets technical specifications), EN 746-2 (Compliant for industrial thermoprocessing equipment), NFPA Compliance (Supported for gas shut-off and safety systems)
- Integrated orifices and inlet orientation choices simplify installation and adjustment.
- The high-velocity stream improves load penetration and temperature uniformity.
Applications
- High-velocity direct furnace heating
Detailed capabilities
Velocity heating and ignition
ThermJet sends an intense stream of combustion gases into the workload to increase penetration and circulation. The burner can ignite within its specified ignition range without a separate pilot. Its operating flexibility includes high excess air, while different control approaches—pulse firing, excess-air regulation or stoichiometric control—can be chosen for the process. These choices should be applied within the selected burner's own limits.
Selecting the engineered combination
Fourteen sizes span the published maximum-input groups. Combustor, fuel, thread and flame-sensing selections are combined from engineered components, with preheated-air models also available. Fuel flexibility is described without requiring a nozzle change. Integral metering orifices assist input adjustment, while air and gas inlets can each rotate in 90-degree steps to accommodate piping independently of one another.
Features and benefits
- Integrated orifices and inlet orientation choices simplify installation and adjustment.
- The high-velocity stream improves load penetration and temperature uniformity.
Published application context
- High-velocity direct furnace heating
Overview
- Models
- TJ (ambient air), TJPCA (preheated air)
- Burner Type
- High‑velocity/medium‑velocity nozzle‑mix industrial gas burner
Combustion/Furnace/Chamber Temperatures
- Maximum Combustion Air Temperature
- TJ: 300 deg F (149 deg C); TJPCA: up to 1000 deg F (538 deg C)
Operating/Process Temperature Ranges
- Process Temperature Range
- 2800 deg F (1540 deg C)
Connections & Interfaces
- Gas and Air Connections
- Adjustable in 90 deg increments
- Pipe Connection Type
- NPT, BSP, Flanged, Welded
Material Specifications
- Combustor Materials
- Alloy, Silicon Carbide, Refractory, Down-firing block
Ignition, Flame & Supervision Specifications
- Flame Supervision
- UV Scanner (all models); Flame rod (TJ0015-TJ0100 only)
- Flame Velocity
- High Velocity: up to 630 ft/s (192 m/s); Medium Velocity: up to 750 ft/s (230 m/s)
- Ignition Type
- Direct spark ignition; low fire start recommended
Installation & Mounting Specifications
- Mounting Options
- Horizontal, vertical up/down
Performance, Flow & Capacity
- Turndown Ratio
- Up to 50:1
Processing & Performance Metrics
- Capacity Range
- 150,000 to 20,000,000 BTU/h (40 to 5333 kW)
- NOx Emissions
- Low NOx; emissions vary by fuel, air temp, and firing rate
Burner/Flame‑Related Lengths
- Flame Length
- 9 to 216 in (229 to 5486 mm) depending on model and fuel
Control, Logic & Functional Behavior
- Control Type
- Modulating, High/Low, Pulse firing, Fixed-air
Dimensions & Size Specifications
- Burner Sizes
- 14 sizes (TJ/TJPCA0015 through TJ/TJPCA2000)
Applications & Compatibility
- Applications
- High‑intensity gas jet for improved furnace circulation, temperature uniformity, and system efficiency
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas, Propane, Butane
Standards & Certifications
- Approvals
- Declaration of Incorporation confirmed, Eurasian Customs Union (Meets technical specifications), EN 746-2 (Compliant for industrial thermoprocessing equipment), NFPA Compliance (Supported for gas shut-off and safety systems)
| Parameter | Published value / configuration |
|---|---|
| Models | TJ (ambient air), TJPCA (preheated air) |
| Burner Type | High‑velocity/medium‑velocity nozzle‑mix industrial gas burner |
| Maximum Combustion Air Temperature | TJ: 300 deg F (149 deg C); TJPCA: up to 1000 deg F (538 deg C) |
| Process Temperature Range | 2800 deg F (1540 deg C) |
| Gas and Air Connections | Adjustable in 90 deg increments |
| Pipe Connection Type | NPT, BSP, Flanged, Welded |
| Combustor Materials | Alloy, Silicon Carbide, Refractory, Down-firing block |
| Flame Supervision | UV Scanner (all models); Flame rod (TJ0015-TJ0100 only) |
| Flame Velocity | High Velocity: up to 630 ft/s (192 m/s); Medium Velocity: up to 750 ft/s (230 m/s) |
| Ignition Type | Direct spark ignition; low fire start recommended |
| Mounting Options | Horizontal, vertical up/down |
| Turndown Ratio | Up to 50:1 |
| Capacity Range | 150,000 to 20,000,000 BTU/h (40 to 5333 kW) |
| NOx Emissions | Low NOx; emissions vary by fuel, air temp, and firing rate |
| Flame Length | 9 to 216 in (229 to 5486 mm) depending on model and fuel |
| Control Type | Modulating, High/Low, Pulse firing, Fixed-air |
| Burner Sizes | 14 sizes (TJ/TJPCA0015 through TJ/TJPCA2000) |
| Applications | High‑intensity gas jet for improved furnace circulation, temperature uniformity, and system efficiency |
| Fuel Type | Natural Gas, Propane, Butane |
| Approvals | Declaration of Incorporation confirmed, Eurasian Customs Union (Meets technical specifications), EN 746-2 (Compliant for industrial thermoprocessing equipment), NFPA Compliance (Supported for gas shut-off and safety systems) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 10004495 | HLDR,CMBSTR,RFRCT,TJ,TJ0750,TJ1000 | Request quotation |
| 10005394-1 | CMBSTR,ALLY,630MM LG,220MM OUTLT,SZ 7,AI | Request quotation |
| 10007035 | CMBSTR,RFRCT,620MM LG,220MM DIA,SZ 8 | Request quotation |
| 10007168 | CMBSTR,ALLY,630MM LG,406MM OUTLT,SZ 7,AI | Request quotation |
| 10007413-1 | NZL,TJ,SZ 7,TJ0750,TJ1000,SS | Request quotation |
| 10007512 | NZL,MACH,TJ1500,TJ2000,SZ 8,ASTM A743 CF | Request quotation |
| 10007632 | CMBSTR,RFRCT,620MM LG,385MM DIA,SZ 8 | Request quotation |
| 10007632-68 | ASY,CMBSTR,RFRCT,620MM LG,385MM DIA,SZ 8 | Request quotation |
| 10015556-1 | TB,ATM,ASY,TJ LQD,TJL0030 | Request quotation |
| 10015564 | BOLT,ANCH,M10 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Thermjet Product Primary Image · Manufacturer ownership retained; republication licence not independently confirmed
ThermJet Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed
ThermJet Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.