ThermJet creates a high-velocity hot-gas stream for load penetration and temperature uniformity in direct-fired processes. Integrated orifices and rotatable inlet connections simplify setup. Fourteen sizes, preheated-air versions, fuel choices and flame-sensing options support different installations, while pulse, excess-air or stoichiometric control can be selected for the application.

Features & Benefits

Maximum Combustion Air Temperature
TJ: 300 deg F (149 deg C)|TJPCA: up to 1000 deg F (538 deg C)
Process Temperature Range
2800 deg F (1540 deg C)
Gas and Air Connections
Adjustable in 90 deg increments
Pipe Connection Type
NPT, BSP, Flanged, Welded
Combustor Materials
Alloy, Silicon Carbide, Refractory, Down-firing block
Flame Supervision
UV Scanner (all models); Flame rod (TJ0015-TJ0100 only)
Mounting Options
Horizontal, vertical up/down
Turndown Ratio
Up to 50:1
Flame Velocity
High Velocity: up to 630 ft/s (192 m/s)|Medium Velocity: up to 750 ft/s (230 m/s)
Capacity Range
150,000 to 20,000,000 BTU/h (40 to 5333 kW)
NOx Emissions
Low NOx; emissions vary by fuel, air temp, and firing rate
Ignition Type
Direct spark ignition; low fire start recommended
Flame Length
9 to 216 in (229 to 5486 mm) depending on model and fuel
Control Type
Modulating, High/Low, Pulse firing, Fixed-air
Burner Sizes
14 sizes (TJ/TJPCA0015 through TJ/TJPCA2000)
Burner Type
High‑velocity/medium‑velocity nozzle‑mix industrial gas burner
Fuel Type
Natural Gas, Propane, Butane
Approvals
Declaration of Incorporation confirmed, Eurasian Customs Union (Meets technical specifications), EN 746-2 (Compliant for industrial thermoprocessing equipment), NFPA Compliance (Supported for gas shut-off and safety systems)
  • Integrated orifices and inlet orientation choices simplify installation and adjustment.
  • The high-velocity stream improves load penetration and temperature uniformity.

Applications

  • High-velocity direct furnace heating

Detailed capabilities

Velocity heating and ignition

ThermJet sends an intense stream of combustion gases into the workload to increase penetration and circulation. The burner can ignite within its specified ignition range without a separate pilot. Its operating flexibility includes high excess air, while different control approaches—pulse firing, excess-air regulation or stoichiometric control—can be chosen for the process. These choices should be applied within the selected burner's own limits.

Manufacturer reference ↗

Selecting the engineered combination

Fourteen sizes span the published maximum-input groups. Combustor, fuel, thread and flame-sensing selections are combined from engineered components, with preheated-air models also available. Fuel flexibility is described without requiring a nozzle change. Integral metering orifices assist input adjustment, while air and gas inlets can each rotate in 90-degree steps to accommodate piping independently of one another.

Manufacturer reference ↗

Features and benefits

  • Integrated orifices and inlet orientation choices simplify installation and adjustment.
  • The high-velocity stream improves load penetration and temperature uniformity.

Manufacturer reference ↗

Published application context

  • High-velocity direct furnace heating

Manufacturer reference ↗

Specifications

Overview

Models
TJ (ambient air), TJPCA (preheated air)
Burner Type
High‑velocity/medium‑velocity nozzle‑mix industrial gas burner

Combustion/Furnace/Chamber Temperatures

Maximum Combustion Air Temperature
TJ: 300 deg F (149 deg C); TJPCA: up to 1000 deg F (538 deg C)

Operating/Process Temperature Ranges

Process Temperature Range
2800 deg F (1540 deg C)

Connections & Interfaces

Gas and Air Connections
Adjustable in 90 deg increments
Pipe Connection Type
NPT, BSP, Flanged, Welded

Material Specifications

Combustor Materials
Alloy, Silicon Carbide, Refractory, Down-firing block

Ignition, Flame & Supervision Specifications

Flame Supervision
UV Scanner (all models); Flame rod (TJ0015-TJ0100 only)
Flame Velocity
High Velocity: up to 630 ft/s (192 m/s); Medium Velocity: up to 750 ft/s (230 m/s)
Ignition Type
Direct spark ignition; low fire start recommended

Installation & Mounting Specifications

Mounting Options
Horizontal, vertical up/down

Performance, Flow & Capacity

Turndown Ratio
Up to 50:1

Processing & Performance Metrics

Capacity Range
150,000 to 20,000,000 BTU/h (40 to 5333 kW)
NOx Emissions
Low NOx; emissions vary by fuel, air temp, and firing rate

Burner/Flame‑Related Lengths

Flame Length
9 to 216 in (229 to 5486 mm) depending on model and fuel

Control, Logic & Functional Behavior

Control Type
Modulating, High/Low, Pulse firing, Fixed-air

Dimensions & Size Specifications

Burner Sizes
14 sizes (TJ/TJPCA0015 through TJ/TJPCA2000)

Applications & Compatibility

Applications
High‑intensity gas jet for improved furnace circulation, temperature uniformity, and system efficiency

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas, Propane, Butane

Standards & Certifications

Approvals
Declaration of Incorporation confirmed, Eurasian Customs Union (Meets technical specifications), EN 746-2 (Compliant for industrial thermoprocessing equipment), NFPA Compliance (Supported for gas shut-off and safety systems)
ThermJet — manufacturer page values
ParameterPublished value / configuration
ModelsTJ (ambient air), TJPCA (preheated air)
Burner TypeHigh‑velocity/medium‑velocity nozzle‑mix industrial gas burner
Maximum Combustion Air TemperatureTJ: 300 deg F (149 deg C); TJPCA: up to 1000 deg F (538 deg C)
Process Temperature Range2800 deg F (1540 deg C)
Gas and Air ConnectionsAdjustable in 90 deg increments
Pipe Connection TypeNPT, BSP, Flanged, Welded
Combustor MaterialsAlloy, Silicon Carbide, Refractory, Down-firing block
Flame SupervisionUV Scanner (all models); Flame rod (TJ0015-TJ0100 only)
Flame VelocityHigh Velocity: up to 630 ft/s (192 m/s); Medium Velocity: up to 750 ft/s (230 m/s)
Ignition TypeDirect spark ignition; low fire start recommended
Mounting OptionsHorizontal, vertical up/down
Turndown RatioUp to 50:1
Capacity Range150,000 to 20,000,000 BTU/h (40 to 5333 kW)
NOx EmissionsLow NOx; emissions vary by fuel, air temp, and firing rate
Flame Length9 to 216 in (229 to 5486 mm) depending on model and fuel
Control TypeModulating, High/Low, Pulse firing, Fixed-air
Burner Sizes14 sizes (TJ/TJPCA0015 through TJ/TJPCA2000)
ApplicationsHigh‑intensity gas jet for improved furnace circulation, temperature uniformity, and system efficiency
Fuel TypeNatural Gas, Propane, Butane
ApprovalsDeclaration of Incorporation confirmed, Eurasian Customs Union (Meets technical specifications), EN 746-2 (Compliant for industrial thermoprocessing equipment), NFPA Compliance (Supported for gas shut-off and safety systems)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
10004495HLDR,CMBSTR,RFRCT,TJ,TJ0750,TJ1000Request quotation
10005394-1CMBSTR,ALLY,630MM LG,220MM OUTLT,SZ 7,AIRequest quotation
10007035CMBSTR,RFRCT,620MM LG,220MM DIA,SZ 8Request quotation
10007168CMBSTR,ALLY,630MM LG,406MM OUTLT,SZ 7,AIRequest quotation
10007413-1NZL,TJ,SZ 7,TJ0750,TJ1000,SSRequest quotation
10007512NZL,MACH,TJ1500,TJ2000,SZ 8,ASTM A743 CFRequest quotation
10007632CMBSTR,RFRCT,620MM LG,385MM DIA,SZ 8Request quotation
10007632-68ASY,CMBSTR,RFRCT,620MM LG,385MM DIA,SZ 8Request quotation
10015556-1TB,ATM,ASY,TJ LQD,TJL0030Request quotation
10015564BOLT,ANCH,M10Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/direct-fired-furnace-burners/thermjet

Last source check: 2026-11-02

Thermjet Product Primary Image · Manufacturer ownership retained; republication licence not independently confirmed

ThermJet Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed

ThermJet Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry