Direct Fired Furnace Burners
NMC Series Dual Fuel Burner
NMC dual-fuel burners accommodate vertical or horizontal firing to fit the available installation space.
NMC dual-fuel burners accommodate vertical or horizontal firing to fit the available installation space. Honeywell describes stable flames, useful turndown and fuel-selection flexibility for heating duties. Published industries include metal treatment, food and beverage, ceramics and automotive manufacturing; exact performance and fuel qualifications require the selected configuration's documentation.
Features & Benefits
- Maximum Air Preheat Temperature
- Up to 425 deg C
- Combustion Principle
- Nozzle‑mixing, high turbulence, flashback‑free
- Maximum Heat Output
- 275 kW, 525 kW, 1100 kW
- Mounting Options
- Roof, base, or side wall installation|Vertical or horizontal
- Control Options
- Manual or automatic via ratio regulator or control valve
- Turndown Ratio
- 8:1 (Gas at 200 deg C), 7:1 (Gas at 425 deg C), 4:1 (Oil)
- Flame Geometry
- Diameter: 10 in, Length: 3.5 ft
- Flame Diameter
- ~ 10 inches
- Ignition Type
- Back-loaded pilot regulator system for consistent ignition
- Burner Series
- NMC Series
- Service Life
- Long‑lasting industrial design
- Flame Length
- ~ 3.5 ft
- Burner Sizes
- 3 sizes: 275 kW, 525 kW, 1100 kW
- Burner Type
- Dual‑fuel industrial burner
- Fuel Type
- Natural Gas, LPG, #2 Oil
- Vertical or horizontal firing helps use available installation space.
Applications
- Metal treatment
- Food and beverage
- Ceramics
- Automotive heating processes
Air/Exhaust/Flue Gas Temperatures
- Maximum Air Preheat Temperature
- Up to 425 deg C
Combustion, Mixing & Fuel Dynamics
- Combustion Principle
- Nozzle‑mixing, high turbulence, flashback‑free
Performance, Flow & Capacity
- Maximum Heat Output
- 275 kW, 525 kW, 1100 kW
- Turndown Ratio
- 8:1 (Gas at 200 deg C), 7:1 (Gas at 425 deg C), 4:1 (Oil)
Installation & Mounting Specifications
- Mounting Options
- Roof, base, or side wall installation; Vertical or horizontal
Control, Logic & Functional Behavior
- Control Options
- Manual or automatic via ratio regulator or control valve
Ignition, Flame & Supervision Specifications
- Flame Geometry
- Diameter: 10 in, Length: 3.5 ft
- Ignition Type
- Back-loaded pilot regulator system for consistent ignition
Dimensions & Size Specifications
- Flame Diameter
- ~ 10 inches
- Burner Sizes
- 3 sizes: 275 kW, 525 kW, 1100 kW
Product Design & Configuration
- Burner Series
- NMC Series
Processing & Performance Metrics
- Service Life
- Long‑lasting industrial design
Burner/Flame‑Related Lengths
- Flame Length
- ~ 3.5 ft
Applications & Compatibility
- Applications
- Metals (heat treatment, re‑heating, continuous furnaces); Steel rolling mills; Food and Beverages (indirect heating); Ceramics; Rotary kilns for chemical/special material mixing; Auto ancillaries
Overview
- Burner Type
- Dual‑fuel industrial burner
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas, LPG, #2 Oil
| Parameter | Published value / configuration |
|---|---|
| Maximum Air Preheat Temperature | Up to 425 deg C |
| Combustion Principle | Nozzle‑mixing, high turbulence, flashback‑free |
| Maximum Heat Output | 275 kW, 525 kW, 1100 kW |
| Turndown Ratio | 8:1 (Gas at 200 deg C), 7:1 (Gas at 425 deg C), 4:1 (Oil) |
| Mounting Options | Roof, base, or side wall installation; Vertical or horizontal |
| Control Options | Manual or automatic via ratio regulator or control valve |
| Flame Geometry | Diameter: 10 in, Length: 3.5 ft |
| Ignition Type | Back-loaded pilot regulator system for consistent ignition |
| Flame Diameter | ~ 10 inches |
| Burner Sizes | 3 sizes: 275 kW, 525 kW, 1100 kW |
| Burner Series | NMC Series |
| Service Life | Long‑lasting industrial design |
| Flame Length | ~ 3.5 ft |
| Applications | Metals (heat treatment, re‑heating, continuous furnaces); Steel rolling mills; Food and Beverages (indirect heating); Ceramics; Rotary kilns for chemical/special material mixing; Auto ancillaries |
| Burner Type | Dual‑fuel industrial burner |
| Fuel Type | Natural Gas, LPG, #2 Oil |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 101028432 | KIT,LIT,NMC,GAS OIL NZL MIX BURNERS | Request quotation |
| 101029523 | BRNR,NMC320,COMB BRNR SWNG AWAY,HK52631X | Request quotation |
| 3515 | FLG,NM BRNR H 126 & L 126 | Request quotation |
| HK13368 | LOCK,NMG215 230 TILE MTG | Request quotation |
| HK14135 | TB ASSY,NMC210 260 OIL INLT | Request quotation |
| HK14573 | INT ASSY,NMC210 BRNR | Request quotation |
| HK14574 | INT ASSY,NMC215 BRNR | Request quotation |
| HK14575 | BKPLT SUB ASSY,NMC210B CAST BRNR | Request quotation |
| HK14576 | BKPLT SUB ASSY,NMC215B CAST BRNR | Request quotation |
| HK14585 | BDY ASSY,NMC215B ATMZR | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Nozzle mix gas and oil burners · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.