Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Direct Fired Furnace Burners

NMC Series Dual Fuel Burner

NMC dual-fuel burners accommodate vertical or horizontal firing to fit the available installation space.

NMC dual-fuel burners accommodate vertical or horizontal firing to fit the available installation space. Honeywell describes stable flames, useful turndown and fuel-selection flexibility for heating duties. Published industries include metal treatment, food and beverage, ceramics and automotive manufacturing; exact performance and fuel qualifications require the selected configuration's documentation.

Features & Benefits

Maximum Air Preheat Temperature
Up to 425 deg C
Combustion Principle
Nozzle‑mixing, high turbulence, flashback‑free
Maximum Heat Output
275 kW, 525 kW, 1100 kW
Mounting Options
Roof, base, or side wall installation|Vertical or horizontal
Control Options
Manual or automatic via ratio regulator or control valve
Turndown Ratio
8:1 (Gas at 200 deg C), 7:1 (Gas at 425 deg C), 4:1 (Oil)
Flame Geometry
Diameter: 10 in, Length: 3.5 ft
Flame Diameter
~ 10 inches
Ignition Type
Back-loaded pilot regulator system for consistent ignition
Burner Series
NMC Series
Service Life
Long‑lasting industrial design
Flame Length
~ 3.5 ft
Burner Sizes
3 sizes: 275 kW, 525 kW, 1100 kW
Burner Type
Dual‑fuel industrial burner
Fuel Type
Natural Gas, LPG, #2 Oil
  • Vertical or horizontal firing helps use available installation space.

Applications

  • Metal treatment
  • Food and beverage
  • Ceramics
  • Automotive heating processes

Specifications

Air/Exhaust/Flue Gas Temperatures

Maximum Air Preheat Temperature
Up to 425 deg C

Combustion, Mixing & Fuel Dynamics

Combustion Principle
Nozzle‑mixing, high turbulence, flashback‑free

Performance, Flow & Capacity

Maximum Heat Output
275 kW, 525 kW, 1100 kW
Turndown Ratio
8:1 (Gas at 200 deg C), 7:1 (Gas at 425 deg C), 4:1 (Oil)

Installation & Mounting Specifications

Mounting Options
Roof, base, or side wall installation; Vertical or horizontal

Control, Logic & Functional Behavior

Control Options
Manual or automatic via ratio regulator or control valve

Ignition, Flame & Supervision Specifications

Flame Geometry
Diameter: 10 in, Length: 3.5 ft
Ignition Type
Back-loaded pilot regulator system for consistent ignition

Dimensions & Size Specifications

Flame Diameter
~ 10 inches
Burner Sizes
3 sizes: 275 kW, 525 kW, 1100 kW

Product Design & Configuration

Burner Series
NMC Series

Processing & Performance Metrics

Service Life
Long‑lasting industrial design

Burner/Flame‑Related Lengths

Flame Length
~ 3.5 ft

Applications & Compatibility

Applications
Metals (heat treatment, re‑heating, continuous furnaces); Steel rolling mills; Food and Beverages (indirect heating); Ceramics; Rotary kilns for chemical/special material mixing; Auto ancillaries

Overview

Burner Type
Dual‑fuel industrial burner

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas, LPG, #2 Oil
NMC Series Dual Fuel Burner — manufacturer page values
ParameterPublished value / configuration
Maximum Air Preheat TemperatureUp to 425 deg C
Combustion PrincipleNozzle‑mixing, high turbulence, flashback‑free
Maximum Heat Output275 kW, 525 kW, 1100 kW
Turndown Ratio8:1 (Gas at 200 deg C), 7:1 (Gas at 425 deg C), 4:1 (Oil)
Mounting OptionsRoof, base, or side wall installation; Vertical or horizontal
Control OptionsManual or automatic via ratio regulator or control valve
Flame GeometryDiameter: 10 in, Length: 3.5 ft
Ignition TypeBack-loaded pilot regulator system for consistent ignition
Flame Diameter~ 10 inches
Burner Sizes3 sizes: 275 kW, 525 kW, 1100 kW
Burner SeriesNMC Series
Service LifeLong‑lasting industrial design
Flame Length~ 3.5 ft
ApplicationsMetals (heat treatment, re‑heating, continuous furnaces); Steel rolling mills; Food and Beverages (indirect heating); Ceramics; Rotary kilns for chemical/special material mixing; Auto ancillaries
Burner TypeDual‑fuel industrial burner
Fuel TypeNatural Gas, LPG, #2 Oil

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
101028432KIT,LIT,NMC,GAS OIL NZL MIX BURNERSRequest quotation
101029523BRNR,NMC320,COMB BRNR SWNG AWAY,HK52631XRequest quotation
3515FLG,NM BRNR H 126 & L 126Request quotation
HK13368LOCK,NMG215 230 TILE MTGRequest quotation
HK14135TB ASSY,NMC210 260 OIL INLTRequest quotation
HK14573INT ASSY,NMC210 BRNRRequest quotation
HK14574INT ASSY,NMC215 BRNRRequest quotation
HK14575BKPLT SUB ASSY,NMC210B CAST BRNRRequest quotation
HK14576BKPLT SUB ASSY,NMC215B CAST BRNRRequest quotation
HK14585BDY ASSY,NMC215B ATMZRRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/direct-fired-furnace-burners/nmc-series-dual-fuel-burner

Last source check: 2026-11-02

Nozzle mix gas and oil burners · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.