Honeywell Process Measurement & Control

Direct Fired Furnace Burners

Menox / BIC..M

Menox BIC..M combines a cast-steel housing and ceramic-tube connection with low-NOx Menox operation.

Menox BIC..M combines a cast-steel housing and ceramic-tube connection with low-NOx Menox operation. Sizes 50–140 cover 10–360 kW, with cold or preheated air up to 450°C. Natural gas is listed directly; other gases require consultation. Threaded fuel/air connections and an internally insulated housing option support installation choices.

Features & Benefits

Maximum Air Preheat Temperature
450 deg C (842 deg F) in menox mode|500 deg C (932 deg F)
Maximum Furnace Temperature
1250 deg C (2282 deg F)
Menox Mode Temperature
Menox low‑NOx mode possible from furnace temperature ≥ 850 deg C (1562 deg F)
Ceramic Tube Material
SiC (Silicon-infiltrated)
Visible Flame Length
45 to 130 cm (17.7 to 51.2 in) depending on size
NOx Reduction Method
Flameless combustion with enlarged reaction zone and reduced peak temperatures
Maintenance Interval
Twice per year (more frequent if media is contaminated)
Combustion Principle
Nozzle‑mixing burner; gas and air mix only at burner head
Flame Supervision
Flame rod standard; UV sensor optional
Turndown Control
On/Off staged control only
Combustion Type
Nozzle-mixing; flameless in menox mode
Flame Velocity
Up to 186 m/s (610 ft/s)
Capacity Range
35 to 360 kW (132 to 1360 kBTU/h) in Flame mode; 40 to 420 kW (1588 kBTU/h) in Menox Mode
Ignition Type
Direct Spark Ignition
Noise Level
~95 dBA open air; ~75 dBA in furnace; lower in menox mode
Burner Type
Low‑NOx gas burner with menox® flameless combustion capability
Fuel Type
Natural Gas (standard), Propane/Butane (on request)
Approvals
Machinery Directive 2006/42/EC Declaration of Incorporation confirmed, Eurasian Customs Union (Meets technical specifications), European Patent (EP 2 442 026 B1 for menox low NOₓ solution), REACH Regulation (Applies to BICW..M (contains RCF/ASW insulation)), EN 746-2 (Compliant for industrial thermoprocessing equipment)
Material
BIC..M: Grey Cast Iron, BICW..M: Steel body with internal ceramic‑fibre insulation
Burner size
50 to 140
Capacity
10 to 360 kW
Uses
for cold air and hot air up to 450°C
Burner Lenghts
300 to 1200 mm

Applications

  • Low-NOx furnace heating with cold or preheated air

Specifications

Overview

Models
BIC..M, BICW..M
Burner Type
Low‑NOx gas burner with menox® flameless combustion capability

Air/Exhaust/Flue Gas Temperatures

Maximum Air Preheat Temperature
450 deg C (842 deg F) in menox mode; 500 deg C (932 deg F)

Maximum/Minimum Temperature Limits

Maximum Furnace Temperature
1250 deg C (2282 deg F)

Operating/Process Temperature Ranges

Menox Mode Temperature
Menox low‑NOx mode possible from furnace temperature ≥ 850 deg C (1562 deg F)

Material Specifications

Ceramic Tube Material
SiC (Silicon-infiltrated)
Material
BIC..M: Grey Cast Iron, BICW..M: Steel body with internal ceramic‑fibre insulation

Burner/Flame‑Related Lengths

Visible Flame Length
45 to 130 cm (17.7 to 51.2 in) depending on size

Combustion Air, Blower & Emissions Specifications

NOx Reduction Method
Flameless combustion with enlarged reaction zone and reduced peak temperatures

Electrical Specifications

Maintenance Interval
Twice per year (more frequent if media is contaminated)

Combustion, Mixing & Fuel Dynamics

Combustion Principle
Nozzle‑mixing burner; gas and air mix only at burner head

Ignition, Flame & Supervision Specifications

Flame Supervision
Flame rod standard; UV sensor optional
Flame Velocity
Up to 186 m/s (610 ft/s)
Ignition Type
Direct Spark Ignition

Performance, Flow & Capacity

Turndown Control
On/Off staged control only

Combustion Design & Characteristics

Combustion Type
Nozzle-mixing; flameless in menox mode

Processing & Performance Metrics

Capacity Range
35 to 360 kW (132 to 1360 kBTU/h) in Flame mode; 40 to 420 kW (1588 kBTU/h) in Menox Mode
Noise Level
~95 dBA open air; ~75 dBA in furnace; lower in menox mode

Applications & Compatibility

Applications
Industrial furnaces in iron and steel, precious, non‑ferrous and light‑metal industries; heat‑treatment furnaces, roller hearth furnaces

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas (standard), Propane/Butane (on request)

Standards & Certifications

Approvals
Machinery Directive 2006/42/EC Declaration of Incorporation confirmed, Eurasian Customs Union (Meets technical specifications), European Patent (EP 2 442 026 B1 for menox low NOₓ solution), REACH Regulation (Applies to BICW..M (contains RCF/ASW insulation)), EN 746-2 (Compliant for industrial thermoprocessing equipment)

Technical Specifications

Burner size
50 to 140
Capacity
10 to 360 kW
Uses
for cold air and hot air up to 450°C
Burner Lenghts
300 to 1200 mm
Menox / BIC..M — manufacturer page values
ParameterPublished value / configuration
ModelsBIC..M, BICW..M
Burner TypeLow‑NOx gas burner with menox® flameless combustion capability
Maximum Air Preheat Temperature450 deg C (842 deg F) in menox mode; 500 deg C (932 deg F)
Maximum Furnace Temperature1250 deg C (2282 deg F)
Menox Mode TemperatureMenox low‑NOx mode possible from furnace temperature ≥ 850 deg C (1562 deg F)
Ceramic Tube MaterialSiC (Silicon-infiltrated)
MaterialBIC..M: Grey Cast Iron, BICW..M: Steel body with internal ceramic‑fibre insulation
Visible Flame Length45 to 130 cm (17.7 to 51.2 in) depending on size
NOx Reduction MethodFlameless combustion with enlarged reaction zone and reduced peak temperatures
Maintenance IntervalTwice per year (more frequent if media is contaminated)
Combustion PrincipleNozzle‑mixing burner; gas and air mix only at burner head
Flame SupervisionFlame rod standard; UV sensor optional
Flame VelocityUp to 186 m/s (610 ft/s)
Ignition TypeDirect Spark Ignition
Turndown ControlOn/Off staged control only
Combustion TypeNozzle-mixing; flameless in menox mode
Capacity Range35 to 360 kW (132 to 1360 kBTU/h) in Flame mode; 40 to 420 kW (1588 kBTU/h) in Menox Mode
Noise Level~95 dBA open air; ~75 dBA in furnace; lower in menox mode
ApplicationsIndustrial furnaces in iron and steel, precious, non‑ferrous and light‑metal industries; heat‑treatment furnaces, roller hearth furnaces
Fuel TypeNatural Gas (standard), Propane/Butane (on request)
ApprovalsMachinery Directive 2006/42/EC Declaration of Incorporation confirmed, Eurasian Customs Union (Meets technical specifications), European Patent (EP 2 442 026 B1 for menox low NOₓ solution), REACH Regulation (Applies to BICW..M (contains RCF/ASW insulation)), EN 746-2 (Compliant for industrial thermoprocessing equipment)
Burner size50 to 140
Capacity10 to 360 kW
Usesfor cold air and hot air up to 450°C
Burner Lenghts300 to 1200 mm

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

7 parts

Part NumberDescriptionEnquiry
KS84031410BRNR,GAS,BIC 65MB 0/35 104 E,W CONN CRMCRequest quotation
KS84033630BIC 100MB-200/235-(118)ERequest quotation
KS84034311BIC 125MG-0/35-(28)ERequest quotation
KS84034320BIC 125MB-100/135-(26)ERequest quotation
KS84035430BIC 140MB-200/235-(75)ERequest quotation
KS84199228ZICW 165MB 200/235 46 E,BRNR GAS,W CONNRequest quotation
KS84199318BIC 100MG-0/35-(124)ERequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/direct-fired-furnace-burners/menox-bic-m

Last source check: 2026-11-02

Burner for gas · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry