Direct Fired Furnace Burners
KINEMAX®
KINEMAX uses a high-velocity discharge to circulate furnace gases and penetrate the workload.
KINEMAX uses a high-velocity discharge to circulate furnace gases and penetrate the workload. With MICRORATIO control valves, firing can be set on-ratio or with excess air or fuel. The family supports clean low-pressure gas or light oil, preheated combustion air and service access through a removable backplate.
Features & Benefits
- Maximum Combustion Air Temperature
- Up to 800 deg F (425 deg C)
- Maximum Furnace Temperature
- Up to 3000 deg F (1650 deg C) with special refractory
- Excess Air Capability
- Up to 4700% depending on size
- Maintenance Interval
- Annual inspection recommended
- Combustion Principle
- Gas and air are mixed in a cast refractory burner block tunnel (nozzle‑mixing)
- Flame Supervision
- UV Scanner standard; flame rod option available on sizes 1.5 to 4
- Mounting Options
- Refractory block, carbon/stainless steel sleeve, flange options
- Turndown Ratio
- Up to 48:1
- Flame Velocity
- Up to 275 ft/s (85 m/s)
- Capacity Range
- 0.38 to 8.0 MBtu/h (110 to 2348 kW)
- Ignition Type
- Direct Spark Ignition with integrated raw‑gas pilot (interrupted pilot recommended)
- Burner Series
- KINEMAX® Series G
- Flame Length
- 4 to 48 in (100 to 1200 mm) depending on size and fuel
- Burner Sizes
- Series G sizes 1.5, 2, 3, 4, 6
- Burner Type
- Nozzle‑mixing, medium‑velocity industrial gas burner
- Fuel Type
- Natural Gas, Propane, Butane, Hydrogen
- Approvals
- Eurasian Customs Union (Compliant), Honeywell MAXON Standards (Applies to all models), WEEE Directive Disposal compliance
- Material
- Housing: gray/ductile iron; Block: castable refractory; Sleeve: AISi 310
- High-velocity discharge promotes furnace circulation and load heating.
- Preheated-air operation can reduce fuel demand.
Applications
- Industrial furnace heating and workload penetration
Detailed capabilities
Ratio choice and service access
KINEMAX can run on-ratio, fuel-rich or air-rich when paired with MICRORATIO, with the extreme excess-air figure applying at minimum capacity. Seven sizes and a broad turndown cover different duties. Preheated or oxygen-enriched air is described, and a removable backplate permits inspection. The refractory block temperature, air-preheat limit and discharge velocity are separate operating facts, each retained with its own condition.
Features and benefits
- High-velocity discharge promotes furnace circulation and load heating.
- Preheated-air operation can reduce fuel demand.
Published application context
- Industrial furnace heating and workload penetration
Combustion/Furnace/Chamber Temperatures
- Maximum Combustion Air Temperature
- Up to 800 deg F (425 deg C)
Maximum/Minimum Temperature Limits
- Maximum Furnace Temperature
- Up to 3000 deg F (1650 deg C) with special refractory
Air & Combustion Air Specifications
- Excess Air Capability
- Up to 4700% depending on size
Electrical Specifications
- Maintenance Interval
- Annual inspection recommended
Combustion, Mixing & Fuel Dynamics
- Combustion Principle
- Gas and air are mixed in a cast refractory burner block tunnel (nozzle‑mixing)
Ignition, Flame & Supervision Specifications
- Flame Supervision
- UV Scanner standard; flame rod option available on sizes 1.5 to 4
- Flame Velocity
- Up to 275 ft/s (85 m/s)
- Ignition Type
- Direct Spark Ignition with integrated raw‑gas pilot (interrupted pilot recommended)
Installation & Mounting Specifications
- Mounting Options
- Refractory block, carbon/stainless steel sleeve, flange options
Performance, Flow & Capacity
- Turndown Ratio
- Up to 48:1
Processing & Performance Metrics
- Capacity Range
- 0.38 to 8.0 MBtu/h (110 to 2348 kW)
Product Design & Configuration
- Burner Series
- KINEMAX® Series G
Burner/Flame‑Related Lengths
- Flame Length
- 4 to 48 in (100 to 1200 mm) depending on size and fuel
Dimensions & Size Specifications
- Burner Sizes
- Series G sizes 1.5, 2, 3, 4, 6
Applications & Compatibility
- Applications
- High‑temperature furnaces such as oxidizers, forge furnaces, annealing furnaces, melting furnaces, lehrs, kilns, ceramic furnaces; suitable where good temperature uniformity without flame impingement is required
Overview
- Burner Type
- Nozzle‑mixing, medium‑velocity industrial gas burner
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas, Propane, Butane, Hydrogen
Standards & Certifications
- Approvals
- Eurasian Customs Union (Compliant), Honeywell MAXON Standards (Applies to all models), WEEE Directive Disposal compliance
Material Specifications
- Material
- Housing: gray/ductile iron; Block: castable refractory; Sleeve: AISi 310
| Parameter | Published value / configuration |
|---|---|
| Maximum Combustion Air Temperature | Up to 800 deg F (425 deg C) |
| Maximum Furnace Temperature | Up to 3000 deg F (1650 deg C) with special refractory |
| Excess Air Capability | Up to 4700% depending on size |
| Maintenance Interval | Annual inspection recommended |
| Combustion Principle | Gas and air are mixed in a cast refractory burner block tunnel (nozzle‑mixing) |
| Flame Supervision | UV Scanner standard; flame rod option available on sizes 1.5 to 4 |
| Flame Velocity | Up to 275 ft/s (85 m/s) |
| Ignition Type | Direct Spark Ignition with integrated raw‑gas pilot (interrupted pilot recommended) |
| Mounting Options | Refractory block, carbon/stainless steel sleeve, flange options |
| Turndown Ratio | Up to 48:1 |
| Capacity Range | 0.38 to 8.0 MBtu/h (110 to 2348 kW) |
| Burner Series | KINEMAX® Series G |
| Flame Length | 4 to 48 in (100 to 1200 mm) depending on size and fuel |
| Burner Sizes | Series G sizes 1.5, 2, 3, 4, 6 |
| Applications | High‑temperature furnaces such as oxidizers, forge furnaces, annealing furnaces, melting furnaces, lehrs, kilns, ceramic furnaces; suitable where good temperature uniformity without flame impingement is required |
| Burner Type | Nozzle‑mixing, medium‑velocity industrial gas burner |
| Fuel Type | Natural Gas, Propane, Butane, Hydrogen |
| Approvals | Eurasian Customs Union (Compliant), Honeywell MAXON Standards (Applies to all models), WEEE Directive Disposal compliance |
| Material | Housing: gray/ductile iron; Block: castable refractory; Sleeve: AISi 310 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 0150KM | 1.5" Kinemax Burner | Request quotation |
| 0150KMMF | 1.5" Mounting Flange | Request quotation |
| 0150KM_CS | 0.55 MBTU/HR GAS BURNER CONFIG SUB ASSEM | Request quotation |
| 0200KM | 2" Kinemax Burner | Request quotation |
| 0200KM-000001 | 0200KM-1BA1V1S00000S01A0 | Request quotation |
| 0200KMMF | 2" Mounting Flange | Request quotation |
| 0200KM_CS | 1.0 MBTU/HR GAS BURNER CONFIG SUB ASSEMB | Request quotation |
| 0300KM | 3" Kinemax Burner | Request quotation |
| 0300KM-000001 | 0300KM-1BA1V1S00000S01A0 | Request quotation |
| 0300KMMF | 3" Mounting Flange | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Kinemax · Manufacturer ownership retained; republication licence not independently confirmed
Kinemax Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed
Kinemax Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.