KINEMAX uses a high-velocity discharge to circulate furnace gases and penetrate the workload.

KINEMAX uses a high-velocity discharge to circulate furnace gases and penetrate the workload. With MICRORATIO control valves, firing can be set on-ratio or with excess air or fuel. The family supports clean low-pressure gas or light oil, preheated combustion air and service access through a removable backplate.

Features & Benefits

Maximum Combustion Air Temperature
Up to 800 deg F (425 deg C)
Maximum Furnace Temperature
Up to 3000 deg F (1650 deg C) with special refractory
Excess Air Capability
Up to 4700% depending on size
Maintenance Interval
Annual inspection recommended
Combustion Principle
Gas and air are mixed in a cast refractory burner block tunnel (nozzle‑mixing)
Flame Supervision
UV Scanner standard; flame rod option available on sizes 1.5 to 4
Mounting Options
Refractory block, carbon/stainless steel sleeve, flange options
Turndown Ratio
Up to 48:1
Flame Velocity
Up to 275 ft/s (85 m/s)
Capacity Range
0.38 to 8.0 MBtu/h (110 to 2348 kW)
Ignition Type
Direct Spark Ignition with integrated raw‑gas pilot (interrupted pilot recommended)
Burner Series
KINEMAX® Series G
Flame Length
4 to 48 in (100 to 1200 mm) depending on size and fuel
Burner Sizes
Series G sizes 1.5, 2, 3, 4, 6
Burner Type
Nozzle‑mixing, medium‑velocity industrial gas burner
Fuel Type
Natural Gas, Propane, Butane, Hydrogen
Approvals
Eurasian Customs Union (Compliant), Honeywell MAXON Standards (Applies to all models), WEEE Directive Disposal compliance
Material
Housing: gray/ductile iron; Block: castable refractory; Sleeve: AISi 310
  • High-velocity discharge promotes furnace circulation and load heating.
  • Preheated-air operation can reduce fuel demand.

Applications

  • Industrial furnace heating and workload penetration

Detailed capabilities

Ratio choice and service access

KINEMAX can run on-ratio, fuel-rich or air-rich when paired with MICRORATIO, with the extreme excess-air figure applying at minimum capacity. Seven sizes and a broad turndown cover different duties. Preheated or oxygen-enriched air is described, and a removable backplate permits inspection. The refractory block temperature, air-preheat limit and discharge velocity are separate operating facts, each retained with its own condition.

Manufacturer reference ↗

Features and benefits

  • High-velocity discharge promotes furnace circulation and load heating.
  • Preheated-air operation can reduce fuel demand.

Manufacturer reference ↗

Published application context

  • Industrial furnace heating and workload penetration

Manufacturer reference ↗

Specifications

Combustion/Furnace/Chamber Temperatures

Maximum Combustion Air Temperature
Up to 800 deg F (425 deg C)

Maximum/Minimum Temperature Limits

Maximum Furnace Temperature
Up to 3000 deg F (1650 deg C) with special refractory

Air & Combustion Air Specifications

Excess Air Capability
Up to 4700% depending on size

Electrical Specifications

Maintenance Interval
Annual inspection recommended

Combustion, Mixing & Fuel Dynamics

Combustion Principle
Gas and air are mixed in a cast refractory burner block tunnel (nozzle‑mixing)

Ignition, Flame & Supervision Specifications

Flame Supervision
UV Scanner standard; flame rod option available on sizes 1.5 to 4
Flame Velocity
Up to 275 ft/s (85 m/s)
Ignition Type
Direct Spark Ignition with integrated raw‑gas pilot (interrupted pilot recommended)

Installation & Mounting Specifications

Mounting Options
Refractory block, carbon/stainless steel sleeve, flange options

Performance, Flow & Capacity

Turndown Ratio
Up to 48:1

Processing & Performance Metrics

Capacity Range
0.38 to 8.0 MBtu/h (110 to 2348 kW)

Product Design & Configuration

Burner Series
KINEMAX® Series G

Burner/Flame‑Related Lengths

Flame Length
4 to 48 in (100 to 1200 mm) depending on size and fuel

Dimensions & Size Specifications

Burner Sizes
Series G sizes 1.5, 2, 3, 4, 6

Applications & Compatibility

Applications
High‑temperature furnaces such as oxidizers, forge furnaces, annealing furnaces, melting furnaces, lehrs, kilns, ceramic furnaces; suitable where good temperature uniformity without flame impingement is required

Overview

Burner Type
Nozzle‑mixing, medium‑velocity industrial gas burner

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas, Propane, Butane, Hydrogen

Standards & Certifications

Approvals
Eurasian Customs Union (Compliant), Honeywell MAXON Standards (Applies to all models), WEEE Directive Disposal compliance

Material Specifications

Material
Housing: gray/ductile iron; Block: castable refractory; Sleeve: AISi 310
KINEMAX® — manufacturer page values
ParameterPublished value / configuration
Maximum Combustion Air TemperatureUp to 800 deg F (425 deg C)
Maximum Furnace TemperatureUp to 3000 deg F (1650 deg C) with special refractory
Excess Air CapabilityUp to 4700% depending on size
Maintenance IntervalAnnual inspection recommended
Combustion PrincipleGas and air are mixed in a cast refractory burner block tunnel (nozzle‑mixing)
Flame SupervisionUV Scanner standard; flame rod option available on sizes 1.5 to 4
Flame VelocityUp to 275 ft/s (85 m/s)
Ignition TypeDirect Spark Ignition with integrated raw‑gas pilot (interrupted pilot recommended)
Mounting OptionsRefractory block, carbon/stainless steel sleeve, flange options
Turndown RatioUp to 48:1
Capacity Range0.38 to 8.0 MBtu/h (110 to 2348 kW)
Burner SeriesKINEMAX® Series G
Flame Length4 to 48 in (100 to 1200 mm) depending on size and fuel
Burner SizesSeries G sizes 1.5, 2, 3, 4, 6
ApplicationsHigh‑temperature furnaces such as oxidizers, forge furnaces, annealing furnaces, melting furnaces, lehrs, kilns, ceramic furnaces; suitable where good temperature uniformity without flame impingement is required
Burner TypeNozzle‑mixing, medium‑velocity industrial gas burner
Fuel TypeNatural Gas, Propane, Butane, Hydrogen
ApprovalsEurasian Customs Union (Compliant), Honeywell MAXON Standards (Applies to all models), WEEE Directive Disposal compliance
MaterialHousing: gray/ductile iron; Block: castable refractory; Sleeve: AISi 310

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
0150KM1.5" Kinemax BurnerRequest quotation
0150KMMF1.5" Mounting FlangeRequest quotation
0150KM_CS0.55 MBTU/HR GAS BURNER CONFIG SUB ASSEMRequest quotation
0200KM2" Kinemax BurnerRequest quotation
0200KM-0000010200KM-1BA1V1S00000S01A0Request quotation
0200KMMF2" Mounting FlangeRequest quotation
0200KM_CS1.0 MBTU/HR GAS BURNER CONFIG SUB ASSEMBRequest quotation
0300KM3" Kinemax BurnerRequest quotation
0300KM-0000010300KM-1BA1V1S00000S01A0Request quotation
0300KMMF3" Mounting FlangeRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/direct-fired-furnace-burners/kinemax

Last source check: 2026-11-02

Kinemax · Manufacturer ownership retained; republication licence not independently confirmed

Kinemax Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

Kinemax Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry