HB and HBD electrode assemblies address pH measurement in difficult chemical, temperature and pressure conditions.
HB and HBD electrode assemblies address pH measurement in difficult chemical, temperature and pressure conditions. HB uses glass-electrode arrangements, while HBD incorporates Durafet solid-state sensing with a long-life reference design. Body-material and mounting choices adapt the assembly to the process, supporting stable readings and reduced maintenance in demanding low- or high-pH service.
Features & Benefits
- HBD sensing
- Durafet with extended-life reference
- Materials
- Configuration-dependent CPVC, polypropylene or Kynar
- Reduces calibration and replacement effort
Applications
- Harsh industrial pH processes
Detailed capabilities
What Is It?
HB uses glass/Meredian sensing and HBD combines Durafet with the rugged reference design. Material choices are qualified: CPVC is identified for HB, polypropylene for HBD, and Kynar within the range. These constructions address hot, pressurized or chemically aggressive processes, but sharing a family page does not establish that each material or sensor is included in every assembly.
How Does It Work?
The filled reference construction resists poisoning, internal blockage and leakage. The 546 threaded-nose design serves inline/submerged work, 551 adds a quick-change adapter and retainer, and 547 fits the specified ball-valve arrangements with its named compression fittings. Each installation style has different removal and fitting requirements rather than one interchangeable threaded mounting.
What Problems Does It Solve?
The reference and rugged materials extend electrode life in difficult chemistry, reducing repeated replacement and calibration. HBD's non-glass Durafet further reduces breakage risk. Cleanability and quick-change forms simplify service, with the complete process/material/pressure combination still needing to match the selected electrode and mounting.
Environmental Conditions
- Pressure & Temperature Rating
- 50 psig, 100 deg C; 100 psig, 500 deg C
- Temperature Sensors
- 8550 ohm Thermistor, Pt1000 RTD
- Operating Range
- 0 to 14 pH
| Parameter | Published value / configuration |
|---|---|
| Pressure & Temperature Rating | 50 psig, 100 deg C; 100 psig, 500 deg C |
| Temperature Sensors | 8550 ohm Thermistor, Pt1000 RTD |
| Operating Range | 0 to 14 pH |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 31008712-501 | MEREDIAN I REFERENCE ELECTRODE | Request quotation |
| 31020749-501 | MER I REDOX ELECTRODE GOLD | Request quotation |
| 31020751-501 | MEREDIAN I REDOX ELECTRODE PLA | Request quotation |
| 31022289-501 | MER I TEMP SENSOR | Request quotation |
| 31027158-501 | RETAINER SS SUPORT TUBE | Request quotation |
| 31028698-501 | PREAMP MODULE | Request quotation |
| 31035974-501 | FLOWING JUNCTION KIT | Request quotation |
| 31063261-501 | MEREDIAN SST SUPPORT TUBE | Request quotation |
| 31074330-501 | ELECTRODE TIP SLOTTED | Request quotation |
| 31074331-501 | ELECTRODE TIP SMOOTH | Request quotation |