HB and HBD Series Ruggedized Electrodes

HB and HBD electrode assemblies address pH measurement in difficult chemical, temperature and pressure conditions.

HB and HBD electrode assemblies address pH measurement in difficult chemical, temperature and pressure conditions. HB uses glass-electrode arrangements, while HBD incorporates Durafet solid-state sensing with a long-life reference design. Body-material and mounting choices adapt the assembly to the process, supporting stable readings and reduced maintenance in demanding low- or high-pH service.

Features & Benefits

HBD sensing
Durafet with extended-life reference
Materials
Configuration-dependent CPVC, polypropylene or Kynar
  • Reduces calibration and replacement effort

Applications

  • Harsh industrial pH processes

Detailed capabilities

What Is It?

HB uses glass/Meredian sensing and HBD combines Durafet with the rugged reference design. Material choices are qualified: CPVC is identified for HB, polypropylene for HBD, and Kynar within the range. These constructions address hot, pressurized or chemically aggressive processes, but sharing a family page does not establish that each material or sensor is included in every assembly.

Manufacturer reference ↗

How Does It Work?

The filled reference construction resists poisoning, internal blockage and leakage. The 546 threaded-nose design serves inline/submerged work, 551 adds a quick-change adapter and retainer, and 547 fits the specified ball-valve arrangements with its named compression fittings. Each installation style has different removal and fitting requirements rather than one interchangeable threaded mounting.

Manufacturer reference ↗

What Problems Does It Solve?

The reference and rugged materials extend electrode life in difficult chemistry, reducing repeated replacement and calibration. HBD's non-glass Durafet further reduces breakage risk. Cleanability and quick-change forms simplify service, with the complete process/material/pressure combination still needing to match the selected electrode and mounting.

Manufacturer reference ↗

Specifications

Environmental Conditions

Pressure & Temperature Rating
50 psig, 100 deg C; 100 psig, 500 deg C
Temperature Sensors
8550 ohm Thermistor, Pt1000 RTD
Operating Range
0 to 14 pH
HB and HBD Series Ruggedized Electrodes — manufacturer page values
ParameterPublished value / configuration
Pressure & Temperature Rating50 psig, 100 deg C; 100 psig, 500 deg C
Temperature Sensors8550 ohm Thermistor, Pt1000 RTD
Operating Range0 to 14 pH

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
31008712-501MEREDIAN I REFERENCE ELECTRODERequest quotation
31020749-501MER I REDOX ELECTRODE GOLDRequest quotation
31020751-501MEREDIAN I REDOX ELECTRODE PLARequest quotation
31022289-501MER I TEMP SENSORRequest quotation
31027158-501RETAINER SS SUPORT TUBERequest quotation
31028698-501PREAMP MODULERequest quotation
31035974-501FLOWING JUNCTION KITRequest quotation
31063261-501MEREDIAN SST SUPPORT TUBERequest quotation
31074330-501ELECTRODE TIP SLOTTEDRequest quotation
31074331-501ELECTRODE TIP SMOOTHRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/process-instruments/analytical-instruments-and-sensors/ph-orp/hb-and-hbd-series-ruggedized-electrodes

Last source check: 2026-11-02

HB and HBD Series Ruggedized Electrodes Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry