pH/ORP
DL3000 ORP Mountings
DL3000 ORP sensors use platinum or gold sensing elements for different process chemistries and connect with the DirectLine DL422 module.
DL3000 ORP sensors use platinum or gold sensing elements for different process chemistries and connect with the DirectLine DL422 module. In-line or submerged installation is supported, with a local display and keypad at the transmitter for setup and calibration. The modular connection allows probe replacement, supporting ongoing oxidation-reduction monitoring and process-treatment adjustments.
Models: DL3000
Features & Benefits
- Sensor options
- Platinum or gold ORP
- Electronics
- DirectLine DL422
- Simplifies probe replacement and setup
Applications
- In-line and submerged ORP measurement
Detailed capabilities
What Is It?
DL3000 uses platinum or gold ORP electrodes with a DL422 transmitter module. The probe is remote from the electronics in the described system, although the introduction calls the functions a combined device. Inline or immersed placement can use different orientations, with the module's local screen/keypad providing setup and calibration access.
How Does It Work?
The Meridian ORP sensor connects to the sensor side of DL422, and a weatherproof power/output cable carries the proportional 4–20 mA signal. The module can mount on a wall, DIN rail or two-inch pipe for outdoor industrial use. The plug-in arrangement supports probe changes without replacing the entire transmitter installation.
What Problems Does It Solve?
Fast ORP observation supports corrective process treatment and reagent control. Local configuration and modular replacement reduce maintenance effort, while the choice of electrode metal adapts the measurement to the process. The source's 'virtually maintenance-free' wording does not remove the need for application-appropriate cleaning or calibration of the installed sensor.
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Manufacturer sources
Last source check: 2026-11-02
DL3000 ORP Mountings Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.