Conductivity
DL4000 Conductivity Cells
DL4000 contacting cells work with the DirectLine conductivity module to measure industrial liquids.
DL4000 contacting cells work with the DirectLine conductivity module to measure industrial liquids. Three cell-constant choices use graphite or platinum electrodes within a PES body, and integral temperature compensation supports the measurement. A fixed cable connects to the remote interface, with submersion, in-line or flow-chamber arrangements available for different installation layouts.
Models: DL4000
Features & Benefits
- Cell constants
- 0.1, 1.0 and 10.0
- Body material
- PES
Applications
- Light-industrial electrolytic conductivity measurement
Detailed capabilities
What Is It?
DL4000 cells connect to the DL423 DirectLine conductivity module. The stated 0.1 and 1.0 constants use graphite, while 10.0 uses platinum. PES construction supports light-industrial electrolytic conductivity duties, with submersed, inline or flow-chamber mounting choices. This material-to-constant mapping is specific and should not be replaced with the titanium mapping of 4973/CCD.
How Does It Work?
An integral temperature compensator accompanies the conductivity electrodes. A fixed 20-foot cable connects through a remote connector assembly to the DirectLine module, creating a modular measurement path. The source describes alternative mounts rather than one supplied chamber for every cell, so process fittings and cable/module configuration remain part of the selected installation.
What Problems Does It Solve?
DirectLine packaging reduces the need for a dedicated separate analyzer installation and simplifies startup, operation and maintenance. Users retain a conductivity sensor matched to its module rather than assembling an unrelated signal path. The cost/accuracy benefits are the manufacturer's stated outcomes for that complete arrangement, not evidence of a universal conductivity range for every cell constant.
Mechanical & Physical Properties
- Compatible Analyzers
- DirectLine DL423, UDA2182, APT4000CC, APT4000TC, APT2000CC, APT2000TC
Environmental Conditions
- Measurement Range
- Suitable for conductivities between 20 and 10,000 μS/cm (EASY), elevated temp/pressure, high purity water (MODERATE), and “dirty” applications (HARSH)
Applications & Compatibility
- Applications
- Industrial Process Conductivity Measurement (Simple and Complex Processes)
- Mounting
- In-Line, Flow Chamber, Immersion
Industries / Applications & Compatibility
- Industries
- Power, Chemical Process, Wastewater, Pure Water and More
| Parameter | Published value / configuration |
|---|---|
| Compatible Analyzers | DirectLine DL423, UDA2182, APT4000CC, APT4000TC, APT2000CC, APT2000TC |
| Measurement Range | Suitable for conductivities between 20 and 10,000 μS/cm (EASY), elevated temp/pressure, high purity water (MODERATE), and “dirty” applications (HARSH) |
| Applications | Industrial Process Conductivity Measurement (Simple and Complex Processes) |
| Mounting | In-Line, Flow Chamber, Immersion |
| Industries | Power, Chemical Process, Wastewater, Pure Water and More |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
6 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 51452150-502 | 4973 STYLE, 10 CONSTANT | Request quotation |
| 51452152-501 | 4905 STYLE, MONEL, 0.1 CONSTAN | Request quotation |
| 51452152-503 | 4905 STYLE, NICKEL, 10 CONSTAN | Request quotation |
| 51452152-504 | 4905 STYLE, PLATINUM, 10 CONST | Request quotation |
| 51452152-505 | 4905 STYLE NICKEL, 50 CONSTANT | Request quotation |
| 51452152-506 | 4905 STYLE, PLATINUM, 50 CONST | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
DL4000 Conductivity Cells Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.