Conductivity
4905 Immersion or Flow Thru Mounting
4905 conductivity cells provide continuous liquid measurement through corrosion-resistant PES bodies and selectable electrode materials.
4905 conductivity cells provide continuous liquid measurement through corrosion-resistant PES bodies and selectable electrode materials. In-line, insertion and immersion arrangements cover different installations, with quick-disconnect options assisting handling. Honeywell publishes different temperature limits for in-line and immersion service, so the cell and mounting must be selected together for the actual process pressure and temperature.
Features & Benefits
- Materials
- PES body with nickel, Monel or platinum electrodes
- Offers mounting choices for different installations
Applications
- Industrial conductivity measurement
Detailed capabilities
What Is It?
4905 cells provide contacting conductivity measurement with nickel, Monel or platinum electrodes. A corrosion-resistant PES body and several mounting/cable arrangements serve industrial water and other conductivity duties. Electrode selection belongs with the required cell configuration; the family description does not make the three electrode materials interchangeable in every process.
How Does It Work?
The source gives inline limits of 140°C/250 psig and immersion limits of 85°C/250 psig. One-inch NPT connections support process insertion or a chamber; immersion requires a user-supplied support tube. The inline disconnect option lets a replacement cell reuse the installed cable without rewiring the analyzer, a maintenance function distinct from withdrawing a live pressurized probe.
What Problems Does It Solve?
Corrosion-resistant construction and alternative mounting methods make conductivity data easier to obtain under varying process conditions. Reusing the cable reduces replacement work, while the separately qualified temperature limits prevent applying the inline thermal capability to immersion service. The intended outcomes are more reliable observation and simpler installation/upkeep, not a universal material-compatibility guarantee.
Communication & Protocols
- Cell Constants Supported
- 0.01, 0.1, 1, 10, and 50 cm⁻¹
Technical Specifications
- Electrical Connections
- 4 or 6 leads with integral Automatic Temperature Compensator; Quick disconnect option available (not for immersion)
Mechanical & Physical Properties
- Electrode Materials
- Nickel, Monel, or Platinum (constants 10 and higher are platinized)
Environmental Conditions
- Temperature Rating
- Up to 140 deg C (284 deg F) maximum continuous
- Pressure Ratings
- Up to 250 psig (1724 kPa)
- Flow Velocity
- Maximum 10 ft/sec (3 m/sec)
Material Specifications
- Cell Body Material
- Polyethersulfone (PES) for high corrosion resistance
I/O Capabilities
- Insertion Depth
- 114 to 175 mm (4.5 to 6.9 in), additional depths available on special order
- Mounting Types
- Immersion (with rigid/flexible plastic pipe), Flow Thru (direct in process stream or bypass with flow chamber)
Network & Connectivity Infrastructure
- Cable/Leadwire
- Tefzel-Covered 18-gage Cable, 20 or 50 ft Long (longer lengths via junction box option)
Applications & Compatibility
- Applications
- Continuous reliable measurement in industrial water processes
Standards & Certifications
- Approvals
- ASME Section VIII, Div. 1, UG-101, CRN #0F11607-5C
| Parameter | Published value / configuration |
|---|---|
| Cell Constants Supported | 0.01, 0.1, 1, 10, and 50 cm⁻¹ |
| Electrical Connections | 4 or 6 leads with integral Automatic Temperature Compensator; Quick disconnect option available (not for immersion) |
| Electrode Materials | Nickel, Monel, or Platinum (constants 10 and higher are platinized) |
| Temperature Rating | Up to 140 deg C (284 deg F) maximum continuous |
| Pressure Ratings | Up to 250 psig (1724 kPa) |
| Flow Velocity | Maximum 10 ft/sec (3 m/sec) |
| Cell Body Material | Polyethersulfone (PES) for high corrosion resistance |
| Insertion Depth | 114 to 175 mm (4.5 to 6.9 in), additional depths available on special order |
| Mounting Types | Immersion (with rigid/flexible plastic pipe), Flow Thru (direct in process stream or bypass with flow chamber) |
| Cable/Leadwire | Tefzel-Covered 18-gage Cable, 20 or 50 ft Long (longer lengths via junction box option) |
| Applications | Continuous reliable measurement in industrial water processes |
| Approvals | ASME Section VIII, Div. 1, UG-101, CRN #0F11607-5C |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
3 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 04905 | CONDUCTIVITY CELL | Request quotation |
| 04908 | REPLACEMENT CONDUCTIVITY CELL | Request quotation |
| 276127 | FLOW CHAMBER (1IN OPENING) | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
4905 Immersion or Flow Thru Mounting Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.