Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Conductivity

4905 Immersion or Flow Thru Mounting

4905 conductivity cells provide continuous liquid measurement through corrosion-resistant PES bodies and selectable electrode materials.

4905 conductivity cells provide continuous liquid measurement through corrosion-resistant PES bodies and selectable electrode materials. In-line, insertion and immersion arrangements cover different installations, with quick-disconnect options assisting handling. Honeywell publishes different temperature limits for in-line and immersion service, so the cell and mounting must be selected together for the actual process pressure and temperature.

Features & Benefits

Materials
PES body with nickel, Monel or platinum electrodes
  • Offers mounting choices for different installations

Applications

  • Industrial conductivity measurement

Detailed capabilities

What Is It?

4905 cells provide contacting conductivity measurement with nickel, Monel or platinum electrodes. A corrosion-resistant PES body and several mounting/cable arrangements serve industrial water and other conductivity duties. Electrode selection belongs with the required cell configuration; the family description does not make the three electrode materials interchangeable in every process.

Manufacturer reference ↗

How Does It Work?

The source gives inline limits of 140°C/250 psig and immersion limits of 85°C/250 psig. One-inch NPT connections support process insertion or a chamber; immersion requires a user-supplied support tube. The inline disconnect option lets a replacement cell reuse the installed cable without rewiring the analyzer, a maintenance function distinct from withdrawing a live pressurized probe.

Manufacturer reference ↗

What Problems Does It Solve?

Corrosion-resistant construction and alternative mounting methods make conductivity data easier to obtain under varying process conditions. Reusing the cable reduces replacement work, while the separately qualified temperature limits prevent applying the inline thermal capability to immersion service. The intended outcomes are more reliable observation and simpler installation/upkeep, not a universal material-compatibility guarantee.

Manufacturer reference ↗

Specifications

Communication & Protocols

Cell Constants Supported
0.01, 0.1, 1, 10, and 50 cm⁻¹

Technical Specifications

Electrical Connections
4 or 6 leads with integral Automatic Temperature Compensator; Quick disconnect option available (not for immersion)

Mechanical & Physical Properties

Electrode Materials
Nickel, Monel, or Platinum (constants 10 and higher are platinized)

Environmental Conditions

Temperature Rating
Up to 140 deg C (284 deg F) maximum continuous
Pressure Ratings
Up to 250 psig (1724 kPa)
Flow Velocity
Maximum 10 ft/sec (3 m/sec)

Material Specifications

Cell Body Material
Polyethersulfone (PES) for high corrosion resistance

I/O Capabilities

Insertion Depth
114 to 175 mm (4.5 to 6.9 in), additional depths available on special order
Mounting Types
Immersion (with rigid/flexible plastic pipe), Flow Thru (direct in process stream or bypass with flow chamber)

Network & Connectivity Infrastructure

Cable/Leadwire
Tefzel-Covered 18-gage Cable, 20 or 50 ft Long (longer lengths via junction box option)

Applications & Compatibility

Applications
Continuous reliable measurement in industrial water processes

Standards & Certifications

Approvals
ASME Section VIII, Div. 1, UG-101, CRN #0F11607-5C
4905 Immersion or Flow Thru Mounting — manufacturer page values
ParameterPublished value / configuration
Cell Constants Supported0.01, 0.1, 1, 10, and 50 cm⁻¹
Electrical Connections4 or 6 leads with integral Automatic Temperature Compensator; Quick disconnect option available (not for immersion)
Electrode MaterialsNickel, Monel, or Platinum (constants 10 and higher are platinized)
Temperature RatingUp to 140 deg C (284 deg F) maximum continuous
Pressure RatingsUp to 250 psig (1724 kPa)
Flow VelocityMaximum 10 ft/sec (3 m/sec)
Cell Body MaterialPolyethersulfone (PES) for high corrosion resistance
Insertion Depth114 to 175 mm (4.5 to 6.9 in), additional depths available on special order
Mounting TypesImmersion (with rigid/flexible plastic pipe), Flow Thru (direct in process stream or bypass with flow chamber)
Cable/LeadwireTefzel-Covered 18-gage Cable, 20 or 50 ft Long (longer lengths via junction box option)
ApplicationsContinuous reliable measurement in industrial water processes
ApprovalsASME Section VIII, Div. 1, UG-101, CRN #0F11607-5C

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

3 parts

Part NumberDescriptionEnquiry
04905CONDUCTIVITY CELLRequest quotation
04908REPLACEMENT CONDUCTIVITY CELLRequest quotation
276127FLOW CHAMBER (1IN OPENING)Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/process-instruments/analytical-instruments-and-sensors/conductivity/4905-immersion-or-flow-thru-mounting

Last source check: 2026-11-02

4905 Immersion or Flow Thru Mounting Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.