5000TC Toroidal Conductivity Sensor

5000TC measures conductivity inductively without exposed contacting electrodes.

5000TC measures conductivity inductively without exposed contacting electrodes. The toroidal sensor addresses solutions where fouling, corrosion or difficult process conditions challenge conventional cells, and can also support concentration or salinity monitoring. Convertible and sanitary forms are available in different polymers, allowing selection for chemical, food, refining, paper, metal-finishing and wastewater processes.

Features & Benefits

Principle
Toroidal electrodeless conductivity
Published range
0.2–2000 mS/cm
  • Reduces electrode fouling and compatibility issues

Applications

  • Chemical concentration
  • Salinity
  • Wastewater
  • Food and dairy

Detailed capabilities

What Is It?

5000TC is an electrodeless toroidal conductivity sensor for fouling/corrosive duties, covering the stated 0.2–2000 mS/cm range and related concentration/salinity work. Convertible or sanitary forms use selectable PEEK, PFA, PVDF or polypropylene construction. Chemical, food/dairy, refining, paper, finishing and wastewater uses require the appropriate material and mounting choice.

Manufacturer reference ↗

How Does It Work?

An AC-driven primary coil induces current in the process liquid, which induces a proportional signal in the pickup coil. The coils do not directly contact the solution, reducing electrode-maintenance problems. A 1.5-inch bore limits flow obstruction, and a 1000-ohm platinum RTD provides temperature compensation. These are inductive cells, not exposed-electrode resistance probes.

Manufacturer reference ↗

What Problems Does It Solve?

The inductive arrangement addresses coating, fouling and chemical attack that complicate contacting conductivity measurements. It supports dependable concentration or salinity monitoring while reducing service associated with exposed electrodes. Material compatibility and process limits remain configuration-specific; 'electrodeless' does not imply that the sensor body never contacts the process.

Manufacturer reference ↗

Specifications

Environmental Conditions

Temperature Compensation
Pt1000Ω Platinum RTD
Measurement Range
0.2 to 2000 milliSiemens/cm
Pressure Limits
PEEK: 200 psi at 302 deg F (13.8 bar at 150 deg C); PFA Teflon®: 200 psi at 302 deg F (13.8 bar at 150 deg C); PVDF: 100 psi at 248 deg F (6.9 bar at 120 deg C); Polypropylene: 100 psi at 212 deg F (6.9 bar at 100 deg C)

Processing & Performance Metrics

Maximum Flow Rate
10 ft/s (3 m/s) gallons per minute

Mechanical & Physical Properties

Wetted Materials
PEEK; PFA Teflon®; PVDF; Polypropylene

I/O Capabilities

Mounting Types
Immersion; Insertion/Removal; Sanitary; Union-Mount

Functional & Control Features

Sensor Styles
Convertible (Immersion, Union, Insertion); Sanitary (CIP, 3A-Approved Materials)

Network & Connectivity Infrastructure

Sensor Cable
(5) Conductor + (2) Isolated Shields; (5) Conductor + (2) Isolated Shields, XLPE Jacket, Rated to 150 deg C (302 deg F), 20 ft (6 m) Length; 20 ft (6 m) Length; Rated to 150 deg C (302 deg F); XLPE Jacket

Applications & Compatibility

Applications
Chemical Concentration; Conductivity; Salinity Measurement in Tough Industrial Environments

Industries / Applications & Compatibility

Industries
Chemical, Food and Dairy, Refinery, Pulp and Paper, Metal Finishing, Wastewater

Others

Operating Temperature Range
10 to 125 deg C; 14 to 257 deg F
5000TC Toroidal Conductivity Sensor — manufacturer page values
ParameterPublished value / configuration
Temperature CompensationPt1000Ω Platinum RTD
Measurement Range0.2 to 2000 milliSiemens/cm
Pressure LimitsPEEK: 200 psi at 302 deg F (13.8 bar at 150 deg C); PFA Teflon®: 200 psi at 302 deg F (13.8 bar at 150 deg C); PVDF: 100 psi at 248 deg F (6.9 bar at 120 deg C); Polypropylene: 100 psi at 212 deg F (6.9 bar at 100 deg C)
Maximum Flow Rate10 ft/s (3 m/s) gallons per minute
Wetted MaterialsPEEK; PFA Teflon®; PVDF; Polypropylene
Mounting TypesImmersion; Insertion/Removal; Sanitary; Union-Mount
Sensor StylesConvertible (Immersion, Union, Insertion); Sanitary (CIP, 3A-Approved Materials)
Sensor Cable(5) Conductor + (2) Isolated Shields; (5) Conductor + (2) Isolated Shields, XLPE Jacket, Rated to 150 deg C (302 deg F), 20 ft (6 m) Length; 20 ft (6 m) Length; Rated to 150 deg C (302 deg F); XLPE Jacket
ApplicationsChemical Concentration; Conductivity; Salinity Measurement in Tough Industrial Environments
IndustriesChemical, Food and Dairy, Refinery, Pulp and Paper, Metal Finishing, Wastewater
Operating Temperature Range10 to 125 deg C; 14 to 257 deg F

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

9 parts

Part NumberDescriptionEnquiry
31063324-501DO PROBE MOUNTING KITRequest quotation
5000TCTOROIDAL ELECTRODELESS CONDUCT PROBERequest quotation
51452187-501FLOW-THRU MOUNTING KIT SS DO PRequest quotation
51452187-502FLOW THROUGH CHEMBERSRequest quotation
51452215-501COAX CABLE 26 GAGE 5CON 25FTRequest quotation
51452215-502EXT CABLE 26 GAGE 5CON 50FTRequest quotation
51452215-503EXT CABLE 26 GAGE 5CON 75FTRequest quotation
51452215-504EXT CABLE 26 GAGE 5CON 100FTRequest quotation
51452226-502IN-LINE MOUNTING KIT PVC DO PRRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/process-instruments/analytical-instruments-and-sensors/conductivity/5000tc-toroidal-conductivity-sensor

Last source check: 2026-11-02