Safety Shut-Off Valves
HON 720
HON 720 is a direct-acting safety shut-off valve for distribution and commercial or industrial installations.
HON 720 is a direct-acting safety shut-off valve for distribution and commercial or industrial installations. Its compact body uses exchangeable functional units, and actuator selection depends on line size. Optional electrical release and valve-closed sensing support integration, while the smaller DN25 version has a different permissible pressure from the larger sizes.
Models: HON 720
Features & Benefits
- Maximum admissible pressure
- 25 bar, DN25 limited to 16 bar
- Sizes
- DN25, DN50, DN80 and DN100
- Response time
- 0.1–0.3 s
- Replaceable functional units simplify maintenance
Applications
- Distribution stations and commercial or industrial facilities
Detailed capabilities
HON 720 — operating design
HON 720 is a direct-acting safety shut-off valve for distribution and commercial or industrial installations. Its compact body uses exchangeable functional units, and actuator selection depends on line size. Optional electrical release and valve-closed sensing support integration, while the smaller DN25 version has a different permissible pressure from the larger sizes.
Size-dependent actuator and pressure limits
HON 720 uses K1a/K2a systems at DN25 and K4/K5/K6 options from DN50. The smallest size is limited to sixteen bar, compared with twenty-five bar for the larger published arrangement. Optional electrical release and proximity indication extend the cartridge-based shut-off, while the separate pressure-trip ranges and response times govern the complete selected assembly.
Published configuration and technical facts
The manufacturer lists these values for HON 720. Version, size and option qualifications remain attached to each fact.
- Maximum Service Pressure: DN 25: 16 bar, DN 50, DN 80, DN 100: 25 bar (depending on flange version)
- Outlet Pressure Range: For over-pressure Wdso 40 mbar to 4.5 bar; For under-pressure Wdsu 5 mbar to 0.4 bar
- Temperature Range: -20 to +60 deg C (Class 2)
- Explosion Protection: No ignition sources, not subject to ATEX 95. Electronic accessories comply with ATEX
- Approvals: DIN-DVGW-Reg.-No. NG-4303AU0020, CE Mark with PED
- Control Devices: K 1a, K 2a (DN 25) or K 4, K 5, K 6 (≥ DN 50)
- Connection Type: DN 25: DIN flanges PN 16, ANSI 150 RF; DN 50/80/100: DIN flanges PN 16, PN 25, ANSI 150 RF
- Response Time: 0.1 to 0.3 sec millisecond
- Body Material: DN 25/50: Cast Steel; DN 80/100: Cast Steel, Ductile Iron
Processing & Performance Metrics
- Maximum Service Pressure
- DN 25: 16 bar, DN 50, DN 80, DN 100: 25 bar (depending on flange version)
Environmental Conditions
- Outlet Pressure Range
- For over-pressure Wdso 40 mbar to 4.5 bar; For under-pressure Wdsu 5 mbar to 0.4 bar
- Temperature Range
- -20 to +60 deg C (Class 2)
Standards & Certifications
- Explosion Protection
- No ignition sources, not subject to ATEX 95. Electronic accessories comply with ATEX
- Approvals
- DIN-DVGW-Reg.-No. NG-4303AU0020, CE Mark with PED
Communication & Protocols
- Control Devices
- K 1a, K 2a (DN 25) or K 4, K 5, K 6 (≥ DN 50)
Technical Specifications
- Connection Type
- DN 25: DIN flanges PN 16, ANSI 150 RF; DN 50/80/100: DIN flanges PN 16, PN 25, ANSI 150 RF
I/O Capabilities
- Response Time
- 0.1 to 0.3 sec millisecond
Material Specifications
- Body Material
- DN 25/50: Cast Steel; DN 80/100: Cast Steel, Ductile Iron
Applications & Compatibility
- Applications
- Safety shut-off valve for gas pressure regulating stations, Natural gas (DVGW G 260) and other gases on request
| Parameter | Published value / configuration |
|---|---|
| Maximum Service Pressure | DN 25: 16 bar, DN 50, DN 80, DN 100: 25 bar (depending on flange version) |
| Outlet Pressure Range | For over-pressure Wdso 40 mbar to 4.5 bar; For under-pressure Wdsu 5 mbar to 0.4 bar |
| Temperature Range | -20 to +60 deg C (Class 2) |
| Explosion Protection | No ignition sources, not subject to ATEX 95. Electronic accessories comply with ATEX |
| Approvals | DIN-DVGW-Reg.-No. NG-4303AU0020, CE Mark with PED |
| Control Devices | K 1a, K 2a (DN 25) or K 4, K 5, K 6 (≥ DN 50) |
| Connection Type | DN 25: DIN flanges PN 16, ANSI 150 RF; DN 50/80/100: DIN flanges PN 16, PN 25, ANSI 150 RF |
| Response Time | 0.1 to 0.3 sec millisecond |
| Body Material | DN 25/50: Cast Steel; DN 80/100: Cast Steel, Ductile Iron |
| Applications | Safety shut-off valve for gas pressure regulating stations, Natural gas (DVGW G 260) and other gases on request |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
1 parts
| Part Number | Description | Enquiry |
|---|---|---|
| HON720 | Savety Shut-Off Valve HON 720 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
HON 720 Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.