Safety Shut-Off Valves
HON 704
HON 704 is a compact safety shut-off valve offered with direct or pilot-operated arrangements.
HON 704 is a compact safety shut-off valve offered with direct or pilot-operated arrangements. It serves industrial consumers and low-load station lines, using replaceable functional cartridges for maintenance. Several actuator systems and optional electrical release or closed-position indication support selection of the complete assembly for the required pressure protection duty.
Models: HON 704
Features & Benefits
- Maximum admissible pressure
- 100 bar
- Response time
- 0.1–0.3 s
- Construction
- Exchangeable cartridges
- Compact layout and serviceable functional units
Applications
- Industrial gas supplies and low-load station lines
Detailed capabilities
HON 704 — operating design
HON 704 is a compact safety shut-off valve offered with direct or pilot-operated arrangements. It serves industrial consumers and low-load station lines, using replaceable functional cartridges for maintenance. Several actuator systems and optional electrical release or closed-position indication support selection of the complete assembly for the required pressure protection duty.
Cartridge assembly and optional signaling
HON 704 offers a compact single shut-off unit for industrial consumers or low-load station branches. The exchangeable functional assembly can use the listed actuator systems, with optional venting. Remote closed indication, electromagnetic release and manual release are selectable additions. Its response and pressure ranges belong to the complete actuator/valve configuration, not every possible safety device.
Published configuration and technical facts
The manufacturer lists these values for HON 704. Version, size and option qualifications remain attached to each fact.
- Maximum Operating Pressure: Up to 100 bar (depending on connection type) kilopascal
- Outlet Pressure Range: For over-pressure Wdso 50 mbar to 90 bar; For under-pressure Wdsu 10 mbar to 90 bar
- Temperature Range: -20 to +60 deg C (Class 2)
- Supplemental Fixture: Electrical Release, Electrical Position Indicator, Manual Release, Screw-In Port for Combination With HON 200/201
- Valve Seat Diameter: 25 mm
- Response Time: 0.1 to 0.3 sec millisecond
- Control Devices: K 1a, K 2a, K 16, K 17, K 18 (various setpoint springs and adjustment ranges for over/under pressure)
Environmental Conditions
- Maximum Operating Pressure
- Up to 100 bar (depending on connection type) kilopascal
- Outlet Pressure Range
- For over-pressure Wdso 50 mbar to 90 bar; For under-pressure Wdsu 10 mbar to 90 bar
- Temperature Range
- -20 to +60 deg C (Class 2)
Mechanical & Physical Properties
- Supplemental Fixture
- Electrical Release, Electrical Position Indicator, Manual Release, Screw-In Port for Combination With HON 200/201
- Valve Seat Diameter
- 25 mm
Standards & Certifications
- Explosion Protection
- All mechanical components of this device are without potential ignition sources and/or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements.
- Approvals
- CE Mark with PED
I/O Capabilities
- Valve Configuration
- Single SSV
- Response Time
- 0.1 to 0.3 sec millisecond
Communication & Protocols
- Control Devices
- K 1a, K 2a, K 16, K 17, K 18 (various setpoint springs and adjustment ranges for over/under pressure)
Technical Specifications
- Connection Type
- Flange (DIN PN 25/40, ANSI 300/600, DN 25/40/50); Inlet/Outlet: Screwed Pipe Connection (DIN 2353, PN 100, for pipe diameters 10 to 42 mm)
Applications & Compatibility
- Applications
- Safety shut-off valve for municipal, industrial, and individual gas pressure regulating systems; Suitable for low-load rails in larger control systems; for natural gas and non-aggressive gases
Material Specifications
- Materials
- Aluminum Alloy or Steel
| Parameter | Published value / configuration |
|---|---|
| Maximum Operating Pressure | Up to 100 bar (depending on connection type) kilopascal |
| Outlet Pressure Range | For over-pressure Wdso 50 mbar to 90 bar; For under-pressure Wdsu 10 mbar to 90 bar |
| Temperature Range | -20 to +60 deg C (Class 2) |
| Supplemental Fixture | Electrical Release, Electrical Position Indicator, Manual Release, Screw-In Port for Combination With HON 200/201 |
| Valve Seat Diameter | 25 mm |
| Explosion Protection | All mechanical components of this device are without potential ignition sources and/or hot faces. They are not subject to ATEX 95 (94/9/EC). All electronic accessories, on the other hand, meet ATEX requirements. |
| Approvals | CE Mark with PED |
| Valve Configuration | Single SSV |
| Response Time | 0.1 to 0.3 sec millisecond |
| Control Devices | K 1a, K 2a, K 16, K 17, K 18 (various setpoint springs and adjustment ranges for over/under pressure) |
| Connection Type | Flange (DIN PN 25/40, ANSI 300/600, DN 25/40/50); Inlet/Outlet: Screwed Pipe Connection (DIN 2353, PN 100, for pipe diameters 10 to 42 mm) |
| Applications | Safety shut-off valve for municipal, industrial, and individual gas pressure regulating systems; Suitable for low-load rails in larger control systems; for natural gas and non-aggressive gases |
| Materials | Aluminum Alloy or Steel |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
1 parts
| Part Number | Description | Enquiry |
|---|---|---|
| HON704 | Savety Shut-Off Valve HON 704 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
HON 704 Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.