Safety Shut-Off Valves
HON 711 - DN 25 thru 150
HON 711 in DN25 through DN150 provides direct or pilot-operated safety shut-off for transmission and industrial gas lines.
HON 711 in DN25 through DN150 provides direct or pilot-operated safety shut-off for transmission and industrial gas lines. Axial flow reduces pressure loss, and manual release is standard among several available release choices. Optional electrical release and closed-position indication extend the valve's integration into station protection and monitoring systems.
Models: HON 711 - DN 25 thru 150
Features & Benefits
- Sizes
- DN25–150
- Maximum admissible pressure
- 100 bar
- Response time
- 0.1–0.3 s
- Low-loss axial passage
Applications
- Transmission stations, power plants and industrial gas facilities
Detailed capabilities
HON 711 - DN 25 thru 150 — operating design
HON 711 in DN25 through DN150 provides direct or pilot-operated safety shut-off for transmission and industrial gas lines. Axial flow reduces pressure loss, and manual release is standard among several available release choices. Optional electrical release and closed-position indication extend the valve's integration into station protection and monitoring systems.
Small and medium HON 711 configurations
The DN25–DN150 range uses the same low-loss axial principle but has a separately published 0.1–0.3 second response. Several actuator systems and flange classes are offered, with class900 on enquiry. Manual release is standard and remote indication or electromagnetic release optional. These limits remain separate from the larger DN200–DN300 page.
Published configuration and technical facts
The manufacturer lists these values for HON 711 - DN 25 thru 150. Version, size and option qualifications remain attached to each fact.
- Maximum Operating Pressure: Up to 100 bar (130 bar on request for ANSI 900 RTJ) kilopascal
- Outlet Pressure Range: For over-pressure Wdso 50 mbar to 90 bar; For under-pressure Wdsu 10 mbar to 90 bar
- Temperature Range: -20 to +60 deg C (Class 2)
- Explosion Protection: Not subject to ATEX 95 (no ignition sources), electronic accessories must satisfy ATEX
- Approvals: CE (PED), DVGW, GOST, GOSTTECHNADSOR, SIL IEC61508
- Control Devices: K10a, K11a/1, K11a/2, K16, K17, K18, K19
- Connection Type: ANSI 300, 600 RF, RTJ, 900 RTJ (PS = 130 bar on request); DIN Flange PN 25, PN 40
- Nominal Widths: DN 25 to 300
- Response Time: 0.1 to 0.3 sec millisecond
- Body Material: A 352 LCC/G20Mn5 QT Medium/Low Alloyed Steel
Environmental Conditions
- Maximum Operating Pressure
- Up to 100 bar (130 bar on request for ANSI 900 RTJ) kilopascal
- Outlet Pressure Range
- For over-pressure Wdso 50 mbar to 90 bar; For under-pressure Wdsu 10 mbar to 90 bar
- Temperature Range
- -20 to +60 deg C (Class 2)
Mechanical & Physical Properties
- Supplemental Fixture
- Manual Release, Current Supply, Current Failure, Remote Indication, Outdoor Type, Special Design
Standards & Certifications
- Explosion Protection
- Not subject to ATEX 95 (no ignition sources), electronic accessories must satisfy ATEX
- Approvals
- CE (PED), DVGW, GOST, GOSTTECHNADSOR, SIL IEC61508
Communication & Protocols
- Control Devices
- K10a, K11a/1, K11a/2, K16, K17, K18, K19
Technical Specifications
- Connection Type
- ANSI 300, 600 RF, RTJ, 900 RTJ (PS = 130 bar on request); DIN Flange PN 25, PN 40
Electrical Specifications
- Nominal Widths
- DN 25 to 300
I/O Capabilities
- Response Time
- 0.1 to 0.3 sec millisecond
Material Specifications
- Body Material
- A 352 LCC/G20Mn5 QT Medium/Low Alloyed Steel
Applications & Compatibility
- Applications
- Safety shut-off valve for gas pressure regulating stations, Natural gas (DVGW G 260) and other gases on request
| Parameter | Published value / configuration |
|---|---|
| Maximum Operating Pressure | Up to 100 bar (130 bar on request for ANSI 900 RTJ) kilopascal |
| Outlet Pressure Range | For over-pressure Wdso 50 mbar to 90 bar; For under-pressure Wdsu 10 mbar to 90 bar |
| Temperature Range | -20 to +60 deg C (Class 2) |
| Supplemental Fixture | Manual Release, Current Supply, Current Failure, Remote Indication, Outdoor Type, Special Design |
| Explosion Protection | Not subject to ATEX 95 (no ignition sources), electronic accessories must satisfy ATEX |
| Approvals | CE (PED), DVGW, GOST, GOSTTECHNADSOR, SIL IEC61508 |
| Control Devices | K10a, K11a/1, K11a/2, K16, K17, K18, K19 |
| Connection Type | ANSI 300, 600 RF, RTJ, 900 RTJ (PS = 130 bar on request); DIN Flange PN 25, PN 40 |
| Nominal Widths | DN 25 to 300 |
| Response Time | 0.1 to 0.3 sec millisecond |
| Body Material | A 352 LCC/G20Mn5 QT Medium/Low Alloyed Steel |
| Applications | Safety shut-off valve for gas pressure regulating stations, Natural gas (DVGW G 260) and other gases on request |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Manufacturer sources
Last source check: 2026-11-02
HON 711 – DN 25 thru 150 Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.