Honeywell 7800 SERIES burner control unit

The modular 7800 SERIES sequences automatically fired single burners using gas, oil or combined fuels.

The modular 7800 SERIES sequences automatically fired single burners using gas, oil or combined fuels. Plug-in amplifiers and detectors determine flame supervision and response time, while the keyboard exposes operating history and lockout information. Regional models have different enclosures and approvals; continuous operation requires the specified detector/amplifier combination.

Features & Benefits

Voltage Rating
230 V and 110 V versions
Supported Relay Module Models
RM7800, RM7823, RM7830, RM7838, RM7840, RM7845, RM7850, RM7865, RM7885, RM7888, RM7890, RM7895, RM7896, RM7897, RM7898, EC7820, EC7823, EC7830, EC7840, EC7850, EC7890, EC7895
Safety Features
Dynamic self-checks; automatic safety shutdown on hardware/software failure
Retrofit Compatibility
Uses existing Honeywell flame detectors for easy upgrades
Product Type
Microprocessor-based burner control and flame supervision system for gas, oil, coal or combination fuel burners
Memory
Non-volatile memory retains data during power failure
Flame Detection
Compatible with Honeywell C7xxx-series flame detectors (UV, IR, ionization)
Fault History
Stores up to 127 fault codes; displays last 6 faults
Display Type
2-line VFD (English), 4-line LCD (English, French, Spanish)
Compatible Flame Detectors
C7008A, C7009A, C7915A, C7012E/F, C7061A/F, C7076A/D, C7961E/F
Compatible Flame Amplifiers
R7847B/C, R7852B, R7851C, R7861A, R7886A
Communication
Integrated Modbus RTU; compatible with Thermal IQ™
Approvals
CE, CSA, FM, UL, AGA, EAC, SIL3 Compliant with self-checking flame scanner
Protection class
Europe: IP00 (cabinet mount only) Americas: NEMA 1 (cabinet or wall mount)
European 7800-series burner controllers (EU)
1.0 or 2.0s (depends on flame amplifier model)
American 7800-series burner controllers (US)
0.8 or 3.0s (depends on flame amplifier model).
  • Plug-in modules allow the flame amplifier and purge arrangement to be selected for the burner.
  • The operator display exposes operating and lockout history.

Applications

  • Automatically fired gas, oil and combined-fuel single burners

Detailed capabilities

Regional construction, flame response and history

The source separates European and American enclosure arrangements, flame-failure response options and approvals. Correct flame amplifier selection governs detector compatibility and continuous-duty qualification. A plug-in ST7800 module establishes pre-purge timing. The keyboard or communications expose recent lockouts, operating hours and flame information; Thermal IQ enables remote monitoring. None of these modular choices should be interpreted as every amplifier, region and detector having the same response or approval.

Manufacturer reference ↗

Features and benefits

  • Plug-in modules allow the flame amplifier and purge arrangement to be selected for the burner.
  • The operator display exposes operating and lockout history.

Manufacturer reference ↗

Published application context

  • Automatically fired gas, oil and combined-fuel single burners

Manufacturer reference ↗

Technical facts in the product overview

  • Protection class: Europe: IP00 (cabinet mount only) Americas: NEMA 1 (cabinet or wall mount)
  • European 7800-series burner controllers (EU): 1.0 or 2.0s (depends on flame amplifier model)
  • American 7800-series burner controllers (US): 0.8 or 3.0s (depends on flame amplifier model).

Manufacturer reference ↗

Specifications

Applications & Compatibility

Applications
Burners, boilers, furnaces, ovens, kilns, hot water heaters, rooftop units
Compatible Flame Detectors
C7008A, C7009A, C7915A, C7012E/F, C7061A/F, C7076A/D, C7961E/F
Compatible Flame Amplifiers
R7847B/C, R7852B, R7851C, R7861A, R7886A

Electrical Specifications

Voltage Rating
230 V and 110 V versions

Actuation, Valve & Motion Control Specifications

Supported Relay Module Models
RM7800, RM7823, RM7830, RM7838, RM7840, RM7845, RM7850, RM7865, RM7885, RM7888, RM7890, RM7895, RM7896, RM7897, RM7898, EC7820, EC7823, EC7830, EC7840, EC7850, EC7890, EC7895

Safety, Protection & Reliability

Safety Features
Dynamic self-checks; automatic safety shutdown on hardware/software failure

System/Upgrade Compatibility

Retrofit Compatibility
Uses existing Honeywell flame detectors for easy upgrades

Overview

Product Type
Microprocessor-based burner control and flame supervision system for gas, oil, coal or combination fuel burners

Control, Software & User Interface Specifications

Memory
Non-volatile memory retains data during power failure
Display Type
2-line VFD (English), 4-line LCD (English, French, Spanish)

Ignition, Flame & Supervision Specifications

Flame Detection
Compatible with Honeywell C7xxx-series flame detectors (UV, IR, ionization)

Alarms, Diagnostics & Monitoring

Fault History
Stores up to 127 fault codes; displays last 6 faults

Communication & Interfaces

Communication
Integrated Modbus RTU; compatible with Thermal IQ™

Standards & Certifications

Approvals
CE, CSA, FM, UL, AGA, EAC, SIL3 Compliant with self-checking flame scanner

Technical Specifications

Protection class
Europe: IP00 (cabinet mount only) Americas: NEMA 1 (cabinet or wall mount)
European 7800-series burner controllers (EU)
1.0 or 2.0s (depends on flame amplifier model)
American 7800-series burner controllers (US)
0.8 or 3.0s (depends on flame amplifier model).
Honeywell 7800 SERIES burner control unit — manufacturer page values
ParameterPublished value / configuration
ApplicationsBurners, boilers, furnaces, ovens, kilns, hot water heaters, rooftop units
Compatible Flame DetectorsC7008A, C7009A, C7915A, C7012E/F, C7061A/F, C7076A/D, C7961E/F
Compatible Flame AmplifiersR7847B/C, R7852B, R7851C, R7861A, R7886A
Voltage Rating230 V and 110 V versions
Supported Relay Module ModelsRM7800, RM7823, RM7830, RM7838, RM7840, RM7845, RM7850, RM7865, RM7885, RM7888, RM7890, RM7895, RM7896, RM7897, RM7898, EC7820, EC7823, EC7830, EC7840, EC7850, EC7890, EC7895
Safety FeaturesDynamic self-checks; automatic safety shutdown on hardware/software failure
Retrofit CompatibilityUses existing Honeywell flame detectors for easy upgrades
Product TypeMicroprocessor-based burner control and flame supervision system for gas, oil, coal or combination fuel burners
MemoryNon-volatile memory retains data during power failure
Display Type2-line VFD (English), 4-line LCD (English, French, Spanish)
Flame DetectionCompatible with Honeywell C7xxx-series flame detectors (UV, IR, ionization)
Fault HistoryStores up to 127 fault codes; displays last 6 faults
CommunicationIntegrated Modbus RTU; compatible with Thermal IQ™
ApprovalsCE, CSA, FM, UL, AGA, EAC, SIL3 Compliant with self-checking flame scanner
Protection classEurope: IP00 (cabinet mount only) Americas: NEMA 1 (cabinet or wall mount)
European 7800-series burner controllers (EU)1.0 or 2.0s (depends on flame amplifier model)
American 7800-series burner controllers (US)0.8 or 3.0s (depends on flame amplifier model).

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type
NameLast checkedType
Product Data ↗2026-11-02PDF

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
200616BACRES SMD 1K OHM 5%3/4W 2010Request quotation
203601CAPACITORRequest quotation
203712ACONDUCTORRequest quotation
203765/UREMOTE DISPLAY BKT FOR S7800Request quotation
204718B/UNEMA 4 COVER ASSYRequest quotation
208693ICRequest quotation
32000103-035CAPACITOR-47UF, 20%, 16VDC, SMRequest quotation
32000320-362RESISTORRequest quotation
32000321-314RESISTORRequest quotation
32000387-634RESISTOR 221K, 0805Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burner-management-systems/burner-control-units/honeywell-7800-series-burner-control-unit

Last source check: 2026-11-02

7800 series · Manufacturer ownership retained; republication licence not independently confirmed

Connected System Diagram · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry