Burner Control Units
Automatic burner control units PFS 778, 748
PFS 778 and PFS 748 are discontinued rack-mounted controls for intermittent gas burners.
PFS 778 and PFS 748 are discontinued rack-mounted controls for intermittent gas burners. The 778 supports selectable main-gas timing for continuously controlled burners; the 748 admits main gas after the flame signal in on/off operation. Both offer air-valve and multiple-flame functions, with selectable flame-failure responses.
Features & Benefits
- Safety Time Operation V2
- 1 seconds
- Safety Time Operation V1
- 1, 3, 5 or 10 seconds
- Start-up Safety Time
- 3, 5 or 10 seconds
- Mains Voltage
- Switchable from 220/240 VAC to 110/120 VAC, for grounded or ungrounded mains
- PFS 748
- main gas following flame signal for burners in On/Off intermittent operation, restart, immediate fault lock-out or delayed reaction time for V1 following flame failure, switchable
- Safety time on start-up
- 3, 5 or 10 s
Applications
- Intermittent gas-burner control
Detailed capabilities
Different main-gas sequences within PFS
PFS 778 can release main gas after either the safety period or a flame-proving period and supports single-electrode operation. PFS 748 admits main gas after the flame signal for on/off burners. Flame-loss behavior can select restart, immediate lockout or delayed V1 response. Both can control an air valve or multiple flames and accept the stated standard control signals. These are historical capabilities of discontinued rack controls.
Published application context
- Intermittent gas-burner control
Technical facts in the product overview
- PFS 748: main gas following flame signal for burners in On/Off intermittent operation, restart, immediate fault lock-out or delayed reaction time for V1 following flame failure, switchable
- Safety time on start-up: 3, 5 or 10 s
Safety, Protection & Reliability
- Safety Time Operation V2
- 1 seconds
- Safety Time Operation V1
- 1, 3, 5 or 10 seconds
Control, Safety & Timing Characteristics
- Start-up Safety Time
- 3, 5 or 10 seconds
Electrical Specifications
- Mains Voltage
- Switchable from 220/240 VAC to 110/120 VAC, for grounded or ungrounded mains
Technical Specifications
- PFS 748
- main gas following flame signal for burners in On/Off intermittent operation, restart, immediate fault lock-out or delayed reaction time for V1 following flame failure, switchable
- Safety time on start-up
- 3, 5 or 10 s
| Parameter | Published value / configuration |
|---|---|
| Safety Time Operation V2 | 1 seconds |
| Safety Time Operation V1 | 1, 3, 5 or 10 seconds |
| Start-up Safety Time | 3, 5 or 10 seconds |
| Mains Voltage | Switchable from 220/240 VAC to 110/120 VAC, for grounded or ungrounded mains |
| PFS 748 | main gas following flame signal for burners in On/Off intermittent operation, restart, immediate fault lock-out or delayed reaction time for V1 following flame failure, switchable |
| Safety time on start-up | 3, 5 or 10 s |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Manufacturer sources
Last source check: 2026-11-02
Burner control unit · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.