BCU 4 (Next Generation)

Next-generation BCU 4 controllers bring burner sequencing, ignition, manual operation and status indication together near the burner.

Next-generation BCU 4 controllers bring burner sequencing, ignition, manual operation and status indication together near the burner. A parameter card and replaceable power module support servicing. Air control, valve proving and high-temperature functions are variant-specific; the source identifies some communications and approvals as still in preparation.

Features & Benefits

Altitude Limit
< 2000 m AMSL
Software Interface
BCSoft (Windows-based engineering tool)
Operation Modes
BCU 480/BCU 460: Intermittent and continuous, BCU 465: Intermittent and continuous + flameless mode
High-Temperature Operation
Yes (>750 deg C)
Flame Control
BCU 480/BCU 460: UV sensor (UVS/UVC), ionization, or temperature-based (HT mode), BCU 465: Intermittent and continuous + flameless mode
Fieldbus Communication
PROFIBUS, PROFINET, EtherNet/IP, Modbus TCP via BCM 400 module
Enclosure Rating
IP20 (BCM module)
Display Type
4-digit 7-segment LED display
Compatible Burner Types
Single-stage, Two-stage, Modulating, Pilot/main, Flameless Operation Burners
Approvals
SIL 3 Capability per EN 61508, PL e per ISO 13849, EU Directives: LVD 2014/35/EU, EMC 2014/30/EU, GAR 2016/426, EN 13611, EN 1854 Compliance, FM Approved (FM 7610), ANSI/CSA, UKCA (460/465), Eurasian Customs Union compliance
Ambient Temperature Range
-20 to +70 deg C (-4 to +158 deg F)|No condensation allowed
  • The parameter card simplifies transferring settings during replacement.
  • A separate power module allows wear components to be replaced.

Applications

  • Industrial gas-burner control near the burner

Detailed capabilities

Configuration-specific functions and approval status

The four-digit display, parameter card and replaceable power section support setup and service. Capacity control targets frequent cycling. Semiconductor air-valve output belongs to the stated F3 variant, valve proving to C1 and high-temperature operation to the named Dx arrangements. The page calls CSA/AGA approvals and protective-bus communication 'in preparation'; those are not current approvals or available functions merely because EU/FM/EAC and SIL/PL statements also appear.

Manufacturer reference ↗

Features and benefits

  • The parameter card simplifies transferring settings during replacement.
  • A separate power module allows wear components to be replaced.

Manufacturer reference ↗

Published application context

  • Industrial gas-burner control near the burner

Manufacturer reference ↗

Specifications

Operating Limits, Durability & Lifecycle

Altitude Limit
< 2000 m AMSL

Control, Software & User Interface Specifications

Software Interface
BCSoft (Windows-based engineering tool)
Display Type
4-digit 7-segment LED display

Control, Logic & Functional Behavior

Operation Modes
BCU 480/BCU 460: Intermittent and continuous, BCU 465: Intermittent and continuous + flameless mode

Overview

Models
BCU 460, BCU 465, BCU 480

Maximum/Minimum Temperature Limits

High-Temperature Operation
Yes (>750 deg C)

Ignition, Flame & Supervision Specifications

Flame Control
BCU 480/BCU 460: UV sensor (UVS/UVC), ionization, or temperature-based (HT mode), BCU 465: Intermittent and continuous + flameless mode

Communication & Interfaces

Fieldbus Communication
PROFIBUS, PROFINET, EtherNet/IP, Modbus TCP via BCM 400 module

Environmental Conditions

Enclosure Rating
IP20 (BCM module)
Ambient Temperature Range
-20 to +70 deg C (-4 to +158 deg F); No condensation allowed

Applications & Compatibility

Compatible Burner Types
Single-stage, Two-stage, Modulating, Pilot/main, Flameless Operation Burners
Applications
BCU 480: Multi‑burner, pilot + main burner, industrial furnaces; BCU 460: General industrial burners; BCU 465: High‑velocity burners, Low‑NOx flameless combustion

Standards & Certifications

Approvals
SIL 3 Capability per EN 61508, PL e per ISO 13849, EU Directives: LVD 2014/35/EU, EMC 2014/30/EU, GAR 2016/426, EN 13611, EN 1854 Compliance, FM Approved (FM 7610), ANSI/CSA, UKCA (460/465), Eurasian Customs Union compliance
BCU 4 (Next Generation) — manufacturer page values
ParameterPublished value / configuration
Altitude Limit< 2000 m AMSL
Software InterfaceBCSoft (Windows-based engineering tool)
Display Type4-digit 7-segment LED display
Operation ModesBCU 480/BCU 460: Intermittent and continuous, BCU 465: Intermittent and continuous + flameless mode
ModelsBCU 460, BCU 465, BCU 480
High-Temperature OperationYes (>750 deg C)
Flame ControlBCU 480/BCU 460: UV sensor (UVS/UVC), ionization, or temperature-based (HT mode), BCU 465: Intermittent and continuous + flameless mode
Fieldbus CommunicationPROFIBUS, PROFINET, EtherNet/IP, Modbus TCP via BCM 400 module
Enclosure RatingIP20 (BCM module)
Ambient Temperature Range-20 to +70 deg C (-4 to +158 deg F); No condensation allowed
Compatible Burner TypesSingle-stage, Two-stage, Modulating, Pilot/main, Flameless Operation Burners
ApplicationsBCU 480: Multi‑burner, pilot + main burner, industrial furnaces; BCU 460: General industrial burners; BCU 465: High‑velocity burners, Low‑NOx flameless combustion
ApprovalsSIL 3 Capability per EN 61508, PL e per ISO 13849, EU Directives: LVD 2014/35/EU, EMC 2014/30/EU, GAR 2016/426, EN 13611, EN 1854 Compliance, FM Approved (FM 7610), ANSI/CSA, UKCA (460/465), Eurasian Customs Union compliance

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
KS22804014Insulation 3-A -casing flue gaRequest quotation
KS74960689Ventilanschlusskabel TC /BRequest quotation
KS74966057Leistungsmodul BCU 4series Q F0 E1 O0 -Request quotation
KS74966073Leistungsmodul BCU 4series Q F3 E0 O0 -Request quotation
KS74966081Leistungsmodul LM400 Q F3 E1 O0 -Request quotation
KS74966105Leistungsmodul BCU 4series W F3 E0 O0 -Request quotation
KS74966113Leistungsmodul BCU 4series W F3 E1 O0 -Request quotation
KS88610001BCU460 3/2WGBS2B1/1Request quotation
KS88610002BCU465 5/1LW3GBS3AB1/1Request quotation
KS88610003CTLR,BRNR,BCU 460 3/1LW3GBB1/1Request quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burner-management-systems/burner-control-units/bcu-4-next-generation

Last source check: 2026-11-02

Burner control units · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry