Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Burner Control Units

Burner control units BCU 560, BCU 565, BCU 580

BCU 560, 565 and 580 place burner supervision and operating-status indication in a compact DIN-rail housing.

BCU 560, 565 and 580 place burner supervision and operating-status indication in a compact DIN-rail housing. Optical communication supports configuration and diagnostics. Capacity control, high-temperature input and valve proving depend on suffix; UVS sensing restricts operation to intermittent duty despite the family's continuous-duty capability with other sensing arrangements.

Features & Benefits

Ambient Temperature Range
-20 to +60 deg C
Fieldbus Communication
Optional BCM 500 module for PROFINET or Modbus TCP
Air Control Interfaces
BCU 560/BCU 565: IC20, IC40, FS-BLAC actuators; Air valve (F3)|BCU 580: IC20, IC40, IC50, RBW actuators or air valve
menox® Low NOx Mode
BCU 560/BCU 580: Not supported|BCU 565: Fully supported on BCU 565..D2
Valve Proving System
Optional
Flame Signal Current
Ionization: 2-25 µA|UV: 5-25 µA
Signal Cable Length
Max 100 m
Software Interface
BCSoft (Windows), opto-adapter PCO 200
Start-up Attempts
1 to 3 attempts
Enclosure Rating
IP20 (device), IP54 (installation cabinet), IP65 (OCU external)
Flame Control
BCU 560/BCU 565: Flame rod, UVS, UVC|BCU 580: Ionization, UVS, UVD (ionization or UV sensor combinations)
Control Modes
BCU 560/BCU 565: Staged, Modulating, On/Off impulse|BCU 580: Staged (F3), Modulating (F1), On/Off impulse
Manual Mode
Integrated; supports actuator and burner control
Burner Type
BCU 560: Single-stage, two-stage, modulating|BCU 565: Single-stage, two-stage, modulating; self‑recuperative burners|BCU 580: Pilot + main burner, two-stage, modulating
Dimensions
100 x 110 x 102 mm
Approvals
EU Certified, AGA, FM, CSA and EAC approved, certified for systems up to SIL 3 (compliant with PL e)

Applications

  • Impulse, modulating or staged gas-burner control

Detailed capabilities

Suffixes determine the extra safety and capacity functions

The BCU 56x/580 family offers manual mode, while F1–F3 adds capacity control. D1 identifies the high-temperature digital input and C1 the valve-proving system. Cabinet DIN-rail mounting combines manual/automatic selection with status indication. Optical diagnostics do not remove the need to select sensing correctly: using UVS restricts duty to intermittent operation even though continuous duty is available with other arrangements.

Manufacturer reference ↗

Published application context

  • Impulse, modulating or staged gas-burner control

Manufacturer reference ↗

Specifications

Overview

Models
BCU 560, BCU 565, BCU 580
Burner Type
BCU 560: Single-stage, two-stage, modulating; BCU 565: Single-stage, two-stage, modulating; self‑recuperative burners; BCU 580: Pilot + main burner, two-stage, modulating

Environmental Conditions

Ambient Temperature Range
-20 to +60 deg C
Enclosure Rating
IP20 (device), IP54 (installation cabinet), IP65 (OCU external)

Communication & Interfaces

Fieldbus Communication
Optional BCM 500 module for PROFINET or Modbus TCP

Air & Combustion Air Specifications

Air Control Interfaces
BCU 560/BCU 565: IC20, IC40, FS-BLAC actuators; Air valve (F3); BCU 580: IC20, IC40, IC50, RBW actuators or air valve

Product Configuration & Options

menox® Low NOx Mode
BCU 560/BCU 580: Not supported; BCU 565: Fully supported on BCU 565..D2

Actuation, Valve & Motion Control Specifications

Valve Proving System
Optional

Electrical Specifications

Flame Signal Current
Ionization: 2-25 µA; UV: 5-25 µA

Dimensions & Length Specifications

Signal Cable Length
Max 100 m

Control, Software & User Interface Specifications

Software Interface
BCSoft (Windows), opto-adapter PCO 200

Control, Logic & System Behavior

Start-up Attempts
1 to 3 attempts

Ignition, Flame & Supervision Specifications

Flame Control
BCU 560/BCU 565: Flame rod, UVS, UVC; BCU 580: Ionization, UVS, UVD (ionization or UV sensor combinations)

Control, Logic & Functional Behavior

Control Modes
BCU 560/BCU 565: Staged, Modulating, On/Off impulse; BCU 580: Staged (F3), Modulating (F1), On/Off impulse
Manual Mode
Integrated; supports actuator and burner control

Applications & Compatibility

Applications
BCU 560: For monitoring/controlling modulating or staged burners, directly ignited burners; BCU 565: For monitoring/controlling modulating or staged burners, directly ignited burners added airflow monitoring features; BCU 580: For monitoring/controlling modulating or staged burners, supports multiple‑burner systems with central air supply.

Dimensions & Weight

Dimensions
100 x 110 x 102 mm

Standards & Certifications

Approvals
EU Certified, AGA, FM, CSA and EAC approved, certified for systems up to SIL 3 (compliant with PL e)
Burner control units BCU 560, BCU 565, BCU 580 — manufacturer page values
ParameterPublished value / configuration
ModelsBCU 560, BCU 565, BCU 580
Burner TypeBCU 560: Single-stage, two-stage, modulating; BCU 565: Single-stage, two-stage, modulating; self‑recuperative burners; BCU 580: Pilot + main burner, two-stage, modulating
Ambient Temperature Range-20 to +60 deg C
Enclosure RatingIP20 (device), IP54 (installation cabinet), IP65 (OCU external)
Fieldbus CommunicationOptional BCM 500 module for PROFINET or Modbus TCP
Air Control InterfacesBCU 560/BCU 565: IC20, IC40, FS-BLAC actuators; Air valve (F3); BCU 580: IC20, IC40, IC50, RBW actuators or air valve
menox® Low NOx ModeBCU 560/BCU 580: Not supported; BCU 565: Fully supported on BCU 565..D2
Valve Proving SystemOptional
Flame Signal CurrentIonization: 2-25 µA; UV: 5-25 µA
Signal Cable LengthMax 100 m
Software InterfaceBCSoft (Windows), opto-adapter PCO 200
Start-up Attempts1 to 3 attempts
Flame ControlBCU 560/BCU 565: Flame rod, UVS, UVC; BCU 580: Ionization, UVS, UVD (ionization or UV sensor combinations)
Control ModesBCU 560/BCU 565: Staged, Modulating, On/Off impulse; BCU 580: Staged (F3), Modulating (F1), On/Off impulse
Manual ModeIntegrated; supports actuator and burner control
ApplicationsBCU 560: For monitoring/controlling modulating or staged burners, directly ignited burners; BCU 565: For monitoring/controlling modulating or staged burners, directly ignited burners added airflow monitoring features; BCU 580: For monitoring/controlling modulating or staged burners, supports multiple‑burner systems with central air supply.
Dimensions100 x 110 x 102 mm
ApprovalsEU Certified, AGA, FM, CSA and EAC approved, certified for systems up to SIL 3 (compliant with PL e)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
KS74966337Spare Parts Pack, OCU 500Request quotation
KS88670765BCU560QC1F1U0D0K1-ERequest quotation
KS88670921BCU560WC0F0U0D1K1-ERequest quotation
KS88670929BCU580QC1F1U0D0K1-ERequest quotation
KS88670934BCU565QC1F1U0D0K1-ERequest quotation
KS88670949BCU580QC0F3U0D1K1-ERequest quotation
KS88670972BCU560QC0F3U0D0K1-ERequest quotation
KS88671020BCU565QC0F3U0D1K1-ERequest quotation
KS88671065BCU560WC1F3U0D1K2-ERequest quotation
KS88671130BCU565QC1F1U0D0K1-ERequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burner-management-systems/burner-control-units/burner-control-units-bcu-560-bcu-565-bcu-580

Last source check: 2026-11-02

Protective System Control · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry