Portable Gauging & Sampling for Terminals
HERMetic UTImeter Otex - Restricted Type - Land Applications
UTImeter Otex is used at an open gauging hatch where open measurement of petroleum or chemical storage is permitted.
UTImeter Otex is used at an open gauging hatch where open measurement of petroleum or chemical storage is permitted. It combines ullage, temperature and oil-water interface detection with manual datum checks. The published configuration includes a weighted probe and optional securing plate, supporting shore-tank inventory and custody-transfer work under the site's allowed operating conditions.
Features & Benefits
- Operating method
- Open gauging where permitted
Applications
- Onshore inventory and custody transfer
- Free-water detection
Detailed capabilities
Product and configuration
UTImeter Otex is used at an open gauging hatch where open measurement of petroleum or chemical storage is permitted. It combines ullage, temperature and oil-water interface detection with manual datum checks. The published configuration includes a weighted probe and optional securing plate, supporting shore-tank inventory and custody-transfer work under the site's allowed operating conditions.
- Operating method: Open gauging where permitted
Operation and integration
Otex is placed at an open gauging hatch and combines ullage, temperature and interface readings with manual datum checks. Its one-inch probe uses the published hydrocarbon-oriented seals and a two-inch load. An optional French plate secures it within suitable gauging pipes or hatches up to six inches. Stored RTD characteristics preserve calibration through tape or sensor replacement.
Application and selection
Although the route contains restricted-type wording, the description explicitly defines open operation where permitted. It should not be marketed as gas-tight closed gauging. The source's historical measurement and approval references need the applicable instrument documents, while inventory, custody and free-water checks remain the stated onshore purposes.
Mechanical & Physical Properties
- Probe
- 1 in sensing probe (standard); 2 in load for high viscous products or manual dip plate detection
Standards & Certifications
- Hazardous Location Approvals
- ATEX II 1 G EEx ia IIB T4/Tamb 50 deg C; China CQST ExiaIIBT4; Factory Mutual CL I, DIV 1, CandD, T4 Tamb 50 deg C and CL I, ZN 0, AEx ia IIB T4 Tamb 50 deg C; IECEx Zone 0 Ex ia IIB T4/Tamb 50 deg C
- Approvals
- API MPMS Chap 3.1A, 7, 8.1; EC Directives; IP PMM Part III-1, IV; ISO 4512, 3170, 4268
Pressure/Operating Limits
- Maximum Tank Overpressure
- Not specified for Otex (Gtex is 0.3 bar)
Technical Specifications
- Temperature Resolution
- 0.01 or 0.1 deg selectable; deg C or deg F selectable
I/O Capabilities
- Measurement Functions
- Ullage (distance from liquid surface to tank top), Temperature, Oil-Water Interface Level, Innage/Reference Height (manual detection of dip datum plate)
- Indication
- Audible and Visible Selectable
- Operation
- Can be used for calibration and verification of automatic level gauging systems; Used on open gauging hatch (restricted type)
Processing & Performance Metrics
- Temperature Accuracy
- ±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F)
- Measurement Accuracy
- Ullage/Interface: ±2 mm (±0.08 in approx.), Tape Accuracy: ±1.5 mm/30 m (±1/16 in/100 ft)
Environmental Conditions
- Temperature Range
- Sensor: -40 to 90 deg C (-40 to 194 deg F); Ambient: -20 to 50 deg C (-4 to 122 deg F)
Overview
- Special Features
- Tape cleaning device, window wiper, tape protection, easy battery and sensor exchange, no calibration needed after sensor exchange Millimeter-PRD
Electrical Specifications
- Power Supply
- Approved 9V Batteries
Applications & Compatibility
- Applications
- Custody Transfer, Inventory Control, Free Water Detection on Shore Tanks
- Sensor Type
- ULTRA Sensing Probe: Stainless Steel Tube, PEEK Head, Ultrasonic Liquid Level Sensor, Temperature Sensor (RTD), Conductivity Electrode
Network & Connectivity Infrastructure
- Tape Length
- 1 mm, 1/16 in resolution; 15 m/50 ft, 30 m/100 ft, 35 m/115 ft; Metric/English Graduation
Functional & Control Features
- Maintenance
- Fully modular, tape, sensor, instrument unit can be changed by user
Software & Interface
- Display
- 8-Character LCD with Backlight
| Parameter | Published value / configuration |
|---|---|
| Probe | 1 in sensing probe (standard); 2 in load for high viscous products or manual dip plate detection |
| Hazardous Location Approvals | ATEX II 1 G EEx ia IIB T4/Tamb 50 deg C; China CQST ExiaIIBT4; Factory Mutual CL I, DIV 1, CandD, T4 Tamb 50 deg C and CL I, ZN 0, AEx ia IIB T4 Tamb 50 deg C; IECEx Zone 0 Ex ia IIB T4/Tamb 50 deg C |
| Approvals | API MPMS Chap 3.1A, 7, 8.1; EC Directives; IP PMM Part III-1, IV; ISO 4512, 3170, 4268 |
| Maximum Tank Overpressure | Not specified for Otex (Gtex is 0.3 bar) |
| Temperature Resolution | 0.01 or 0.1 deg selectable; deg C or deg F selectable |
| Measurement Functions | Ullage (distance from liquid surface to tank top), Temperature, Oil-Water Interface Level, Innage/Reference Height (manual detection of dip datum plate) |
| Indication | Audible and Visible Selectable |
| Operation | Can be used for calibration and verification of automatic level gauging systems; Used on open gauging hatch (restricted type) |
| Temperature Accuracy | ±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F) |
| Measurement Accuracy | Ullage/Interface: ±2 mm (±0.08 in approx.), Tape Accuracy: ±1.5 mm/30 m (±1/16 in/100 ft) |
| Temperature Range | Sensor: -40 to 90 deg C (-40 to 194 deg F); Ambient: -20 to 50 deg C (-4 to 122 deg F) |
| Special Features | Tape cleaning device, window wiper, tape protection, easy battery and sensor exchange, no calibration needed after sensor exchange Millimeter-PRD |
| Power Supply | Approved 9V Batteries |
| Applications | Custody Transfer, Inventory Control, Free Water Detection on Shore Tanks |
| Sensor Type | ULTRA Sensing Probe: Stainless Steel Tube, PEEK Head, Ultrasonic Liquid Level Sensor, Temperature Sensor (RTD), Conductivity Electrode |
| Tape Length | 1 mm, 1/16 in resolution; 15 m/50 ft, 30 m/100 ft, 35 m/115 ft; Metric/English Graduation |
| Maintenance | Fully modular, tape, sensor, instrument unit can be changed by user |
| Display | 8-Character LCD with Backlight |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| TS 10197 | Tape 15m IIB stand assy Otex | Request quotation |
| TS 10199 | Tape 35m IIB stand assy Otex | Request quotation |
| TS 10200 | Tape 15m IIB chem. assy Otex | Request quotation |
| TS 10202 | Tape 35m IIB chem. assy Otex | Request quotation |
| TS 10230 | Tape 25m IIB chem. assy Otex | Request quotation |
| TS 10244 | TAPE 25M IIB STAND. ASSY RTEX & GTEX | Request quotation |
| TS 11269 | Frame Otex | Request quotation |
| TS 11270 | Base plate for UTImeter Otex | Request quotation |
| TS 40115 | Toothed lock washer M4 Type A | Request quotation |
| TS 50701 | Carrying case UTImeter Otex 50X40X20 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
HERMetic UTImeter Otex - Restricted Type - Land Applications · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic UTImeter Otex - Restricted Type - Land Applications · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic UTImeter Otex - Restricted Type - Land Applications · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic UTImeter Otex - Restricted Type - Land Applications · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic UTImeter Otex - Restricted Type - Land Applications · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.