Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Portable Gauging & Sampling for Terminals

HERMetic Sampler GT & Sampler GT Chem - Land Applications

GT and GT Chem provide gas-tight sampling through two-inch tank valves in refinery and terminal storage.

GT and GT Chem provide gas-tight sampling through two-inch tank valves in refinery and terminal storage. A 0.47-litre bottle collects the sample, with gravity transfer through a distribution block into the laboratory container. Graduated tape shows collection depth, and alternative bottle types adapt the standard zone arrangement to spot, bottom or running sampling.

Features & Benefits

Capacity
0.47 litre
Transfer
Gravity through distribution block
  • Limits vapor release and operator exposure

Applications

  • Closed sampling of storage-tank liquids and chemicals

Detailed capabilities

Product and configuration

GT and GT Chem provide gas-tight sampling through two-inch tank valves in refinery and terminal storage. A 0.47-litre bottle collects the sample, with gravity transfer through a distribution block into the laboratory container. Graduated tape shows collection depth, and alternative bottle types adapt the standard zone arrangement to spot, bottom or running sampling.

  • Capacity: 0.47 litre
  • Transfer: Gravity through distribution block

Manufacturer reference ↗

Operation and integration

GT and GT Chem mount through the appropriate two-inch deck-valve adaptor and collect liquid with a bottle on a thirty-metre tape. A distribution block provides gravity transfer into the laboratory bottle. Both have a published 0.47 litre capacity; FKM seals distinguish GT from FFKM in the Chem arrangement. Zone bottles are standard, with other patterns available on request.

Manufacturer reference ↗

Application and selection

The enclosed collection limits vapor release during storage-tank sampling of liquids that present exposure, fire or pollution hazards. Choosing a Chem label does not remove the need to establish seal and medium compatibility. Bottle type determines the intended collection method, while the connection and approval apply to the complete described assembly.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

Portable Gauging Devices and Samplers for Land Applications

View resource ↗
Manufacturer Document

Honeywell Authorized Service Stations - HERMetic Portable Gauging & Sampling Products

View resource ↗

Specifications

Standards & Certifications

Hazardous Location Approvals
ATEX II 1 G c IIB T6

Mechanical & Physical Properties

Sampling Height Measurement
On Graduated Tape

Pressure/Operating Limits

Maximum Tank Overpressure
0.3 bar

I/O Capabilities

Sampling Bottle Capacity
Approx. 0.5 liters
Operation
Avoids pressure release and fume exposure; Closed sampling

Applications & Compatibility

Valve Compatibility
2 in HERMetic Compact Valves (adapters for other valves available)
Applications
HERMetic Sampler GT - Sampling of Hydrocarbons (Fire, Health, Air Pollution Hazard), HERMetic Sampler GT Chem - Sampling of Corrosive Liquids (Fire, Health, Air Pollution Hazard)

Material Specifications

Gasket Material
HERMetic Sampler GT - FKM; HERMetic Sampler GT Chem - FFKM
Materials
Stainless Steel AISI 316, PTFE, PVDF

Dimensions & Weight

Unit Height
1016 mm

Network & Connectivity Infrastructure

Tape Length
30 m/100 ft
HERMetic Sampler GT & Sampler GT Chem - Land Applications — manufacturer page values
ParameterPublished value / configuration
Hazardous Location ApprovalsATEX II 1 G c IIB T6
Sampling Height MeasurementOn Graduated Tape
Maximum Tank Overpressure0.3 bar
Sampling Bottle CapacityApprox. 0.5 liters
OperationAvoids pressure release and fume exposure; Closed sampling
Valve Compatibility2 in HERMetic Compact Valves (adapters for other valves available)
ApplicationsHERMetic Sampler GT - Sampling of Hydrocarbons (Fire, Health, Air Pollution Hazard), HERMetic Sampler GT Chem - Sampling of Corrosive Liquids (Fire, Health, Air Pollution Hazard)
Gasket MaterialHERMetic Sampler GT - FKM; HERMetic Sampler GT Chem - FFKM
MaterialsStainless Steel AISI 316, PTFE, PVDF
Unit Height1016 mm
Tape Length30 m/100 ft

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

4 parts

Part NumberDescriptionEnquiry
TS 10089HERMetic Sampler GT without bottle incl.Request quotation
TS 10090HERMetic Sampler GT Chem wo bottleRequest quotation
TS 10099HERMETIC SAMPLER GT W/BOTTLE+CASE+HCEXTNRequest quotation
TS 98181HERMetic Sampler GT 35 m incl. caseRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/terminals/portable-gauging-and-sampling-for-terminals/hermetic-sampler-gt-and-sampler-gt-chem-land-applications

Last source check: 2026-11-02

HERMetic Sampler GT & Sampler GT Chem - Land Applications · Manufacturer ownership retained; republication licence not independently confirmed