Portable Gauging & Sampling for Terminals
HERMetic Sampler GTX Chem - Land Applications
GTX Chem supplies gas-tight sample collection for refinery and terminal tanks, including low- and high-viscosity chemicals.
GTX Chem supplies gas-tight sample collection for refinery and terminal tanks, including low- and high-viscosity chemicals. It attaches to a two-inch HERMetic valve and uses a pump to pressurize the transfer chamber. Bottle choices support spot, bottom, running and zone methods, allowing users to choose the collection pattern while containing tank vapors.
Features & Benefits
- Transfer
- Pump-assisted chamber pressurization
- Limits tank-vapor release during sampling
Applications
- Terminal and refinery chemical storage
Detailed capabilities
Product and configuration
GTX Chem supplies gas-tight sample collection for refinery and terminal tanks, including low- and high-viscosity chemicals. It attaches to a two-inch HERMetic valve and uses a pump to pressurize the transfer chamber. Bottle choices support spot, bottom, running and zone methods, allowing users to choose the collection pattern while containing tank vapors.
- Transfer: Pump-assisted chamber pressurization
Operation and integration
GTX Chem quick-connects to a two-inch HERMetic compact valve and uses pump pressure in the upper chamber to discharge the collected liquid. The source offers bottles for spot, bottom, running and zone methods. It publishes thirty-metre tape, approximately 0.47 litre capacity and 0.3 bar maximum tank overpressure for this land-application page.
Application and selection
The sampler addresses low/high-viscosity chemicals and closed collection at terminal or refinery storage. Pump-assisted transfer is its distinguishing feature; the page does not establish the same fully atmosphere-isolated transfer as GTN Chem. Maintain the stated pressure, bottle and construction-safety configuration when selecting it.
Standards & Certifications
- Hazardous Location Approvals
- ATEX II 1 G c IIB T6
Mechanical & Physical Properties
- Sampling Height Measurement
- On Graduated Tape
Capacity/Volume Specifications
- Laboratory Bottle Capacity
- 0.47 liters (16 oz)
Pressure/Operating Limits
- Maximum Tank Overpressure
- 0.3 bar
I/O Capabilities
- Sampling Bottle Capacity
- Approx. 0.5 liters
- Operation
- Gas-tight construction avoids pressure release and fume exposure; Transfer of liquid from sampling bottle to laboratory bottle by over pressurizing upper chamber with a pump
Applications & Compatibility
- Valve Compatibility
- 2 in HERMetic Compact Valves (adapters for other valves available)
- Applications
- Closed Sampling of Corrosive or Hazardous Liquids (fire, health, air pollution hazard)
Overview
- Special Features
- Graduated tape for sampling height, closed transfer, robust and safe for hazardous environments Millimeter-PRD
Material Specifications
- Gasket Material
- FFKM (for corrosive liquids)
- Materials
- Stainless Steel AISI 316, PTFE, PVDF
Dimensions & Weight
- Unit Height
- 800 mm
Network & Connectivity Infrastructure
- Tape Length
- 30 m/100 ft
| Parameter | Published value / configuration |
|---|---|
| Hazardous Location Approvals | ATEX II 1 G c IIB T6 |
| Sampling Height Measurement | On Graduated Tape |
| Laboratory Bottle Capacity | 0.47 liters (16 oz) |
| Maximum Tank Overpressure | 0.3 bar |
| Sampling Bottle Capacity | Approx. 0.5 liters |
| Operation | Gas-tight construction avoids pressure release and fume exposure; Transfer of liquid from sampling bottle to laboratory bottle by over pressurizing upper chamber with a pump |
| Valve Compatibility | 2 in HERMetic Compact Valves (adapters for other valves available) |
| Applications | Closed Sampling of Corrosive or Hazardous Liquids (fire, health, air pollution hazard) |
| Special Features | Graduated tape for sampling height, closed transfer, robust and safe for hazardous environments Millimeter-PRD |
| Gasket Material | FFKM (for corrosive liquids) |
| Materials | Stainless Steel AISI 316, PTFE, PVDF |
| Unit Height | 800 mm |
| Tape Length | 30 m/100 ft |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Manufacturer sources
Last source check: 2026-11-02
HERMetic Sampler GTX Chem - Land Applications · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic Sampler GTX Chem - Land Applications · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic Sampler GTX Chem - Land Applications image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.