Portable Gauging & Sampling for Terminals
HERMetic UTImeter Gtex 2000 - Closed Type - Land Applications
Gtex 2000 performs closed portable gauging in terminal and refinery tanks, combining ullage, temperature and oil-water interface sensing with manual reference-height checks.
Gtex 2000 performs closed portable gauging in terminal and refinery tanks, combining ullage, temperature and oil-water interface sensing with manual reference-height checks. Its weighted probe and chemical-resistant sealing arrangement suit the published storage duties. Connection to a compatible vapor-control valve contains tank gas, while tape protection and accessible battery replacement support repeated inventory and custody-transfer checks.
Features & Benefits
- Checks
- Ullage, temperature, interface and manual reference height
- Contains tank vapors during gauging
Applications
- Onshore custody transfer
- Inventory control
- Free-water detection
Detailed capabilities
Product and configuration
Gtex 2000 performs closed portable gauging in terminal and refinery tanks, combining ullage, temperature and oil-water interface sensing with manual reference-height checks. Its weighted probe and chemical-resistant sealing arrangement suit the published storage duties. Connection to a compatible vapor-control valve contains tank gas, while tape protection and accessible battery replacement support repeated inventory and custody-transfer checks.
- Checks: Ullage, temperature, interface and manual reference height
Operation and integration
Gtex 2000 combines electronic ullage, temperature and oil-water interface sensing with manual detection of the datum plate for innage/reference-height work. The page specifies a chemical-oriented gasket/connector arrangement and a two-inch load on the one-inch sensing probe. RTD characteristics are stored in the sensor so changing a tape or sensor does not require new system calibration.
Application and selection
A suitable vapor-control valve maintains closed shore-tank operation. Interchangeable adaptors, tape protection and battery access support repeated inventory and custody checks. The source lists historical standards and approvals, which should be associated with the actual selected instrument rather than treated as current blanket acceptance of every tank or medium.
Mechanical & Physical Properties
- Probe
- 2 in load on sensing probe for operation in any kind of product; Heavy probe for manual dip plate detection
Standards & Certifications
- Hazardous Location Approvals
- ATEX II 1 G EEx ia IIB T4/Tamb 50 deg C; China CQST ExiaIIBT4; Factory Mutual CL I, DIV 1, CandD, T4 Tamb 50 deg C and CL I, ZN 0, AEx ia IIB T4 Tamb 50 deg C; IECEx Zone 0 Ex ia IIB T4/Tamb 50 deg C
- Approvals
- API MPMS Chap 3.1A, 7, 8.1; EC Directives; IP PMM Part III-1, IV; ISO 4512, 3170, 4268
Pressure/Operating Limits
- Maximum Tank Overpressure
- 0.3 bar (4.4 psi)
Technical Specifications
- Temperature Resolution
- 0.01 or 0.1 deg selectable; deg C or deg F selectable
I/O Capabilities
- Measurement Functions
- Ullage (distance from liquid surface to tank top), Temperature, Oil-Water Interface Level, Innage/Reference Height (manual detection of dip datum plate)
- Indication
- Audible and Visible Selectable
- Operation
- Avoids gas release during operation; Used with HERMetic vapor control valve
Processing & Performance Metrics
- Temperature Accuracy
- ±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F)
- Measurement Accuracy
- Ullage/Interface: ±2 mm (±0.08 in approx.), Tape Accuracy: ±1.5 mm/30 m (±1/16 in/100 ft)
Environmental Conditions
- Temperature Range
- Sensor: -40 to 90 deg C (-40 to 194 deg F); Ambient: -20 to 50 deg C (-4 to 122 deg F)
Overview
- Special Features
- Tape cleaning device, window wiper, tape protection, easy battery and sensor exchange, no calibration needed after sensor exchange Millimeter-PRD
Electrical Specifications
- Power Supply
- Approved 9V Batteries
Applications & Compatibility
- Applications
- Custody Transfer, Inventory Control, Free Water Detection on Shore Tanks
- Sensor Type
- ULTRA Sensing Probe: Stainless Steel Tube, PEEK Head, Ultrasonic Liquid Level Sensor, Temperature Sensor (RTD), Conductivity Electrode
Network & Connectivity Infrastructure
- Tape Length
- 1 mm, 1/16 in resolution; 30 m/100 ft (Standard); Metric/English Graduation
Software & Interface
- Display
- 8-Character LCD with Backlight
| Parameter | Published value / configuration |
|---|---|
| Probe | 2 in load on sensing probe for operation in any kind of product; Heavy probe for manual dip plate detection |
| Hazardous Location Approvals | ATEX II 1 G EEx ia IIB T4/Tamb 50 deg C; China CQST ExiaIIBT4; Factory Mutual CL I, DIV 1, CandD, T4 Tamb 50 deg C and CL I, ZN 0, AEx ia IIB T4 Tamb 50 deg C; IECEx Zone 0 Ex ia IIB T4/Tamb 50 deg C |
| Approvals | API MPMS Chap 3.1A, 7, 8.1; EC Directives; IP PMM Part III-1, IV; ISO 4512, 3170, 4268 |
| Maximum Tank Overpressure | 0.3 bar (4.4 psi) |
| Temperature Resolution | 0.01 or 0.1 deg selectable; deg C or deg F selectable |
| Measurement Functions | Ullage (distance from liquid surface to tank top), Temperature, Oil-Water Interface Level, Innage/Reference Height (manual detection of dip datum plate) |
| Indication | Audible and Visible Selectable |
| Operation | Avoids gas release during operation; Used with HERMetic vapor control valve |
| Temperature Accuracy | ±0.1 deg C (0 to 70 deg C), ±0.2 deg F (32 to 158 deg F) |
| Measurement Accuracy | Ullage/Interface: ±2 mm (±0.08 in approx.), Tape Accuracy: ±1.5 mm/30 m (±1/16 in/100 ft) |
| Temperature Range | Sensor: -40 to 90 deg C (-40 to 194 deg F); Ambient: -20 to 50 deg C (-4 to 122 deg F) |
| Special Features | Tape cleaning device, window wiper, tape protection, easy battery and sensor exchange, no calibration needed after sensor exchange Millimeter-PRD |
| Power Supply | Approved 9V Batteries |
| Applications | Custody Transfer, Inventory Control, Free Water Detection on Shore Tanks |
| Sensor Type | ULTRA Sensing Probe: Stainless Steel Tube, PEEK Head, Ultrasonic Liquid Level Sensor, Temperature Sensor (RTD), Conductivity Electrode |
| Tape Length | 1 mm, 1/16 in resolution; 30 m/100 ft (Standard); Metric/English Graduation |
| Display | 8-Character LCD with Backlight |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
4 parts
| Part Number | Description | Enquiry |
|---|---|---|
| TS 11289 | Carter Gtex 2000 base | Request quotation |
| TS 12113 | Carter Gtex 2000 | Request quotation |
| TS 40004 | Hex nut M4 | Request quotation |
| TS NGU2K | HERMETIC UTIMETER GTEX2000 N SERIES | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
HERMetic UTImeter Gtex 2000 - Closed Type - Land Applications · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic UTImeter Gtex 2000 - Closed Type - Land Applications · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic UTImeter Gtex 2000 - Closed Type - Land Applications · Manufacturer ownership retained; republication licence not independently confirmed
HERMetic UTImeter Gtex 2000 - Closed Type - Land Applications · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.
