Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Portable Gauging & Sampling for Terminals

HERMetic Sampler A-2 and A-4 - Land Applications

HERMetic A-2 and A-4 collect samples from onshore storage tanks where the permitted method allows restricted sampling and open transfer.

HERMetic A-2 and A-4 collect samples from onshore storage tanks where the permitted method allows restricted sampling and open transfer. The bottle is lowered on a graduated tape, with different bottle types supporting depth-specific collection. Published capacities reach 0.47 litre for A-2 and 1.8 litres for A-4, allowing selection around sample-volume needs.

Features & Benefits

Capacities
A-2 up to 0.47 litre

Applications

  • Crude-oil storage sampling where open transfer is permitted

Detailed capabilities

Product and configuration

HERMetic A-2 and A-4 collect samples from onshore storage tanks where the permitted method allows restricted sampling and open transfer. The bottle is lowered on a graduated tape, with different bottle types supporting depth-specific collection. Published capacities reach 0.47 litre for A-2 and 1.8 litres for A-4, allowing selection around sample-volume needs.

  • Capacities: A-2 up to 0.47 litre

Manufacturer reference ↗

Operation and integration

A sampling bottle is lowered through the tank valve on a graduated tape and its position read through a window. The source distinguishes A-2's approximate 0.47 litre and A-4's 1.8 litre capacity, with thirty-metre tape and an additional A-4 length option. Bottle removal supports interchange among zone, spot, running and bottom sampling arrangements.

Manufacturer reference ↗

Application and selection

The source authorizes these descriptions for restricted sampling and explicitly says transfer to the laboratory bottle occurs open. They must therefore remain separate from gas-tight GT products. The valve size follows the sampler version; contradictory generic two-inch wording should not override A-4's described four-inch mounting.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

Portable Gauging Devices and Samplers for Land Applications

View resource ↗
Manufacturer Document

Honeywell Authorized Service Stations - HERMetic Portable Gauging & Sampling Products

View resource ↗

Specifications

Standards & Certifications

Hazardous Location Approvals
ATEX II 1 G c IIB T6

Mechanical & Physical Properties

Sampling Height Measurement
Via graduated tape and viewing window

Pressure/Operating Limits

Maximum Tank Overpressure
0.3 bar

Functional & Control Features

Sampling Methods
HERMetic Sampler A-2: Restricted sampling, sampler housing mounted on top of 2 in deck valve, sample taken by vertical movement of bottle inside liquid; HERMetic Sampler A-4: Restricted sampling, sampler housing mounted on top of 4 in deck valve, sample taken by vertical movement of bottle inside liquid

Processing & Performance Metrics

Sample Transfer
Liquid transferred from sampling bottle to laboratory bottle by opening transfer valve at bottom; Pump can be connected to accelerate transfer

Dimensions & Weight

Unit Height
HERMetic Sampler A-4: 770 mm, HERMetic Sampler A-2: Not explicitly stated, but typically less than A-4

Network & Connectivity Infrastructure

Tape Length
30 m/100 ft (Standard), 50 m tape length available on request

Material Specifications

Materials
AISI 316 stainless steel, Rilsan Coated Aluminum
HERMetic Sampler A-2 and A-4 - Land Applications — manufacturer page values
ParameterPublished value / configuration
Hazardous Location ApprovalsATEX II 1 G c IIB T6
Sampling Height MeasurementVia graduated tape and viewing window
Maximum Tank Overpressure0.3 bar
Sampling MethodsHERMetic Sampler A-2: Restricted sampling, sampler housing mounted on top of 2 in deck valve, sample taken by vertical movement of bottle inside liquid; HERMetic Sampler A-4: Restricted sampling, sampler housing mounted on top of 4 in deck valve, sample taken by vertical movement of bottle inside liquid
Sample TransferLiquid transferred from sampling bottle to laboratory bottle by opening transfer valve at bottom; Pump can be connected to accelerate transfer
Unit HeightHERMetic Sampler A-4: 770 mm, HERMetic Sampler A-2: Not explicitly stated, but typically less than A-4
Tape Length30 m/100 ft (Standard), 50 m tape length available on request
MaterialsAISI 316 stainless steel, Rilsan Coated Aluminum

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

2 parts

Part NumberDescriptionEnquiry
TS 10088HERMetic Sampler A-2 without bottleRequest quotation
TS 10093HERMetic Sampler A-4 without bottleRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/terminals/portable-gauging-and-sampling-for-terminals/hermetic-sampler-a-2-and-a-4-land-applications

Last source check: 2026-11-02

HERMetic Sampler A-2 and A-4 - Land Applications image · Manufacturer ownership retained; republication licence not independently confirmed

HERMetic Sampler A-2 and A-4 - Land Applications image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry