Enraf Tank Gauging
Entis Tank Inventory System
ENTIS manages tank inventories using the Experion platform and information supplied through the CIU888.
ENTIS manages tank inventories using the Experion platform and information supplied through the CIU888. It brings tank measurements and calculations into operational screens for inventory, product movement and custody-transfer duties. The modular software supports bulk and distribution terminals, allowing operators to use a consistent view of tank conditions and associated inventory information during daily terminal activities.
Features & Benefits
- Platform
- Experion
- Field integration
- CIU888
- Centralizes terminal inventory information
Applications
- Refineries
- Bulk-storage and distribution terminals
Detailed capabilities
Product and configuration
ENTIS manages tank inventories using the Experion platform and information supplied through the CIU888. It brings tank measurements and calculations into operational screens for inventory, product movement and custody-transfer duties. The modular software supports bulk and distribution terminals, allowing operators to use a consistent view of tank conditions and associated inventory information during daily terminal activities.
- Platform: Experion
- Field integration: CIU888
Operation and integration
ENTIS uses information gathered and calculated by CIU888 to present tank levels, tables, icons, density/temperature profiles, trends, reports and tank calculations. The source describes integration over the CIU's supported interfaces and an Experion-based modular architecture. These views support operators with different tasks while maintaining shared inventory information and the relevant application security.
Application and selection
The software addresses inventory, product movement and custody-related accounting at refineries and terminals. The page discusses W&M-certified applications and alarm/leak/overfill information; those functions depend on the full configured gauges, gateway and alarm architecture. The inventory program should not be described as an independent field overfill detector.
Movement Operation
- Advanced Movement
- Absolute and relative measurement types; Alerts on progress toward level/volume/mass; Closed Movement reports; Configuration report; Infrastructure pipelines; Main Screen -; Many-to-one; Objects: Tanks, pipes, train, truck, ship or Custom creation; One-to-many; Overview of all movements; Views: Armed, Active and Closed
- Simple Movement
- Group details Movement view; Movement reports; One-to-One with; Simple UI calculator; View movements on tanks
Alarm & Event Management
- Trending
- Preconfigured trends accessible via Experion Station Equipment view
- Data Historization
- Data points from ENTIS historized for up to 1 year
Funtional Specifications
- Tank Monitoring & Visualization
- Configurable View to monitor all or selected tanks; Configurable View to monitor up-to 5 entities per tank; Delta Funtion; Export to CSV; Export view and group, or single tank, to CSV; Setup Scheduled Export of a group and view, or a single tank; Tabular View up to 80 tanks per page
- Server Redundancy
- File and data synchronization of ENTIS data; Server failover detection and automatic switchover
- Scenario Analysis
- Forward and back calculations; Report of calculation; Tank calculator for hypothetical inventory changes
- Reports
- Group detail: Crudes, CTL, General Products, Inventory, Measured, Tank Totals; PDF reports with static templates; Select from Group and View defined in Group details; Tank detail - Legal Metrology approved & Custom Group report templates
- Profile
- Density (interface and tank) and Up to 50 points using 954 Servo gauge; Graphical or tabular view of profile data; Temperature profiles from probes
- Panel PC
- Experion Panel PC touch screen support
- Multi-Screen
- Dual screeen; Experion SafeView; Single screen (with multi windows)
Product License Specifications
- Maximum Number of Tanks
- 400 (5 CIU’s, 80 Tanks); 80 tanks per CIU; With Dual Gauges - 320 (8 CIU’s, 40 Tanks)
- Maximum Number of Stations
- 20 Stations
- Maximum Number of CIU 888s Supported
- Non-Redundant: 8, Redundant: 8 (16 CIU’s)
- Legal Metrology
- Yes
- Languages Supported
- English, French, Italian, Dutch, Spanish, Chinese, Polish, German, Hungarian
- Experion HS Version
- R530.1 with HMI Web update 2
- CIU 888 Version
- R220.1
| Parameter | Published value / configuration |
|---|---|
| Advanced Movement | Absolute and relative measurement types; Alerts on progress toward level/volume/mass; Closed Movement reports; Configuration report; Infrastructure pipelines; Main Screen -; Many-to-one; Objects: Tanks, pipes, train, truck, ship or Custom creation; One-to-many; Overview of all movements; Views: Armed, Active and Closed |
| Simple Movement | Group details Movement view; Movement reports; One-to-One with; Simple UI calculator; View movements on tanks |
| Trending | Preconfigured trends accessible via Experion Station Equipment view |
| Data Historization | Data points from ENTIS historized for up to 1 year |
| Tank Monitoring & Visualization | Configurable View to monitor all or selected tanks; Configurable View to monitor up-to 5 entities per tank; Delta Funtion; Export to CSV; Export view and group, or single tank, to CSV; Setup Scheduled Export of a group and view, or a single tank; Tabular View up to 80 tanks per page |
| Server Redundancy | File and data synchronization of ENTIS data; Server failover detection and automatic switchover |
| Scenario Analysis | Forward and back calculations; Report of calculation; Tank calculator for hypothetical inventory changes |
| Reports | Group detail: Crudes, CTL, General Products, Inventory, Measured, Tank Totals; PDF reports with static templates; Select from Group and View defined in Group details; Tank detail - Legal Metrology approved & Custom Group report templates |
| Profile | Density (interface and tank) and Up to 50 points using 954 Servo gauge; Graphical or tabular view of profile data; Temperature profiles from probes |
| Panel PC | Experion Panel PC touch screen support |
| Multi-Screen | Dual screeen; Experion SafeView; Single screen (with multi windows) |
| Maximum Number of Tanks | 400 (5 CIU’s, 80 Tanks); 80 tanks per CIU; With Dual Gauges - 320 (8 CIU’s, 40 Tanks) |
| Maximum Number of Stations | 20 Stations |
| Maximum Number of CIU 888s Supported | Non-Redundant: 8, Redundant: 8 (16 CIU’s) |
| Legal Metrology | Yes |
| Languages Supported | English, French, Italian, Dutch, Spanish, Chinese, Polish, German, Hungarian |
| Experion HS Version | R530.1 with HMI Web update 2 |
| CIU 888 Version | R220.1 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| EN-BASMNT | ENTIS SIMPLE MOVEMENT | Request quotation |
| EN-CUSTWM | ENTIS CUSTODY TRANSFER - W&M | Request quotation |
| EN-DEMOSW | ENTIS DEMO SOFTWARE | Request quotation |
| EN-EP-HME01K | EXPERION HS 1000 POINTS ADDER | Request quotation |
| EN-EP-HMESAO | HONEYWELL APPLICATION COMMUNICATION | Request quotation |
| EN-INFMNT | ENTIS ADVANCE MOVEMENT INFRASTRUCTURE PI | Request quotation |
| EN-LANG-CH | ENTIS LANGUAGE IN TRADITIONAL CHINESE | Request quotation |
| EN-LANG-DE | ENTIS LANGUAGE IN GERMAN | Request quotation |
| EN-LANG-EN | ENTIS LANGUAGE IN ENGLISH | Request quotation |
| EN-LANG-ES | ENTIS LANGUAGE IN SPANISH | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Tank Inventory Systems Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.