Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Enraf Tank Gauging

Enraf Smart Displays

Enraf smart displays present readings and diagnostics from compatible servo or radar gauges at a more accessible location.

Enraf smart displays present readings and diagnostics from compatible servo or radar gauges at a more accessible location. The portfolio includes SmartView, HART SmartView and RMA805 arrangements, with tank-side or portable choices for local configuration. Ground-level indication reduces the need to climb tanks, while supported models provide the appropriate hazardous-area and measurement-display capabilities.

Features & Benefits

Portfolio
SmartView, HART SmartView and RMA805
  • Reduces tank climbing for reading instruments

Applications

  • Tank-side indication and local gauge configuration

Detailed capabilities

Product and configuration

Enraf smart displays present readings and diagnostics from compatible servo or radar gauges at a more accessible location. The portfolio includes SmartView, HART SmartView and RMA805 arrangements, with tank-side or portable choices for local configuration. Ground-level indication reduces the need to climb tanks, while supported models provide the appropriate hazardous-area and measurement-display capabilities.

  • Portfolio: SmartView, HART SmartView and RMA805

Manufacturer reference ↗

Operation and integration

SmartView can be installed as a tank-side indicator or used as a portable configuration tool. HART SmartView supplies the published weights-and-measures level-visualization role, while RMA805 places a display associated with the Enraf radar or servo gauge at a remote location such as the tank bottom. The intrinsically safe SmartView arrangements are distinct from a general unapproved display.

Manufacturer reference ↗

Application and selection

Ground-level readings reduce tank climbing and make routine status or diagnostic access easier. Choose the display against the gauge, communication and local configuration requirement. A portable tool and a permanently mounted indicator are different installation choices, and the W&M display role is specifically described for the applicable HART SmartView arrangement.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

Enraf Flexline Remote Indicator RMA805 - Brochure - English

View resource ↗
Manufacturer Document

HART SmartView Display Unit - Brochure - English

View resource ↗
Manufacturer Document

2212200 HPS CAS Valero Dublin Customer Success Story A4

View resource ↗

Specifications

Environmental Safety

Ambient Temperature Range
-25 to +65 deg C (-13 to +149 deg F)
Safety Approvals
IECEx, ATEX, ANSI NFPA 70
Protection Class
IP66/IP67

Mechanical

Weight
5 kg (11 lb)
Dimensions
247 mm x 266 mm x 100 mm (9-3/4 x 10-7/16 x 3-15/16 in)
Cable Entries
M20 or 3/4 in NPT

Technical Specifications

Product Type
HART Physical Layer Enraf SmartView protocol

Electrical

Power Supply
Intrinsically safe from SmartRadar FlexLine Transmission
Cable Connections
2 wire

Options

Mounting Bracket
For railing 11-1/2 , 2 or 3 in

Mechenical

Keyboard
5 key touch panel

VITO Interface

Housing
Chrome Free Coated Aluminum (< 0.5 % Magnesium)

Display

Display Type
LCD graphic display 64 x 128 dots
Enraf Smart Displays — manufacturer page values
ParameterPublished value / configuration
Ambient Temperature Range-25 to +65 deg C (-13 to +149 deg F)
Safety ApprovalsIECEx, ATEX, ANSI NFPA 70
Protection ClassIP66/IP67
Weight5 kg (11 lb)
Dimensions247 mm x 266 mm x 100 mm (9-3/4 x 10-7/16 x 3-15/16 in)
Cable EntriesM20 or 3/4 in NPT
Product TypeHART Physical Layer Enraf SmartView protocol
Power SupplyIntrinsically safe from SmartRadar FlexLine Transmission
Cable Connections2 wire
Mounting BracketFor railing 11-1/2 , 2 or 3 in
Keyboard5 key touch panel
HousingChrome Free Coated Aluminum (< 0.5 % Magnesium)
Display TypeLCD graphic display 64 x 128 dots

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

1 parts

Part NumberDescriptionEnquiry
RMA805Enraf FlexLine Remote IndicatorRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/terminals/enraf-tank-gauging/enraf-smart-displays

Last source check: 2026-11-02

Enraf Smart Displays image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.