Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Enraf Tank Gauging

Communication Interface Unit (CIU888)

CIU888 connects tank gauges with inventory and operating applications at bulk-storage sites.

CIU888 connects tank gauges with inventory and operating applications at bulk-storage sites. It gathers and processes field information, making measured and calculated values available to different users and supporting custody-transfer reporting. Commissioning and remote-service tools help maintain the connected gauges, while the gateway provides a common path between tank instrumentation and terminal information systems.

Models: CIU888

Features & Benefits

Role
Tank-gauge communication and inventory-data gateway
  • Makes tank data available to multiple operational users

Applications

  • Tank farms
  • Bulk storage
  • Custody-transfer reporting

Detailed capabilities

Product and configuration

CIU888 connects tank gauges with inventory and operating applications at bulk-storage sites. It gathers and processes field information, making measured and calculated values available to different users and supporting custody-transfer reporting. Commissioning and remote-service tools help maintain the connected gauges, while the gateway provides a common path between tank instrumentation and terminal information systems.

  • Role: Tank-gauge communication and inventory-data gateway

Manufacturer reference ↗

Operation and integration

CIU888 continuously scans connected gauges and calculates tank inventory using the described API/ASTM methods. Legacy serial connections can retain existing applications, while Ethernet provides additional access. Continuously synchronized redundant units maintain data status and validity for Weights and Measures purposes. A Ring of Light and LCD give local status, and web diagnostics support remote service and analysis.

Manufacturer reference ↗

Application and selection

The gateway makes measured and calculated inventory information available for product movements, custody reporting and operational monitoring. Its redundancy, security and calculation arrangements belong to the configured CIU system. The page's authority and standards references should be matched to the selected custody-transfer installation rather than assumed for every connected application.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

Communication Interface Unit (CIU888) - System Administration Manual

View resource ↗
Manufacturer Document

2212200 HPS CAS Valero Dublin Customer Success Story A4

View resource ↗

Specifications

Environmental Safety

Ambient Temperature Range
0 to +60 deg C (32 to 140 deg F)
Storage Temperature Range
-20 to 85 deg C (-4 to 185 deg F)
Approvals
IEC 61010-1:2010, EN 61010-1:2010, CE, CAN/CSA, UL Std. 61010-1, NAMUR NE 107, NMI (Netherlands)

I/O Capabilities

Tank Database Capacity
80 tanks (one gauge per tank), 40 tanks (two gauges per tank)

Device & Network Capacity

Supported Gauges
All GPU-Enabled Tank Gauges (811, 813, 866, 854, 872, 873, 877, 894, 990, 954) and Emerson TRL/2

Environmental Conditions

Relative Humidity
0 to 90% RH (Non-Condensing)

Redundancy & Synchronization

Redundancy
Hot Standby, Real-Time Synchronization; Redundant Ethernet Ports (redundancy controlled by Entis or modbus host)

Communication & Protocols

Protocols Supported
Modbus TCP/IP, OPC UA TCP, Serial Modbus, CIU 858/880 Emulation, Enraf BPM Fieldbus, TRL/2 Fieldbus, RS-232/RS-485
Host Connectivity
Ethernet/LAN-3X Modbus TCP/IP ethernet (FTEA, FTEB and Office LAN); Serial Ports-2X modbus serial (+ 4 additional ports by using optional slots)
Field Connectivity
Available Option Boards - Enraf BPM fieldbus, Serial modbus (master) and Serial GPU input and TRL/2 Fieldbus; Field Ports - 6X option slots (of which 4 ports can be used for serial host connectivity); Wireless Connectivity - ISA 100 via Honeywell WDM through TCP/IP to serial converters

Electrical

Power Supply
100 to 240 VAC, Auto-Ranging (-15 to +10%), 45 to 65 Hz, max 60 VA (35 VA Nominal)

Software & Interface

Operating System
Linux Arch, 4 GB Flash Memory (Upgradable)

VITO Interface

Mounting
Wall, Rack, or Tabletop

Technical Specifications

Function
Field scanning and communication interface for tank inventory applications with Optional embedded tank inventory calculation functionality

Mechanical & Physical Properties

Enclosure
IP30 (NEMA 1)

Mechanical

Dimensions
400 x 93 x 283 mm (15-3/4 x 3-3/4 x 11-1/4 in)

Applications & Compatibility

Applications
For all applications requiring accurate and reliable process and inventory data, such as refineries, tank farms and terminals. Data is suitable for custody transfer, safe product transfer and tank farm operation.

Others

User Interface
LCD Color Display (50 x 38 mm, 320 x 240 px), Navigation Keys, LED Ring for Status, Key Lock Switches for Config/W&M Sealing
Communication Interface Unit (CIU888) — manufacturer page values
ParameterPublished value / configuration
Ambient Temperature Range0 to +60 deg C (32 to 140 deg F)
Storage Temperature Range-20 to 85 deg C (-4 to 185 deg F)
ApprovalsIEC 61010-1:2010, EN 61010-1:2010, CE, CAN/CSA, UL Std. 61010-1, NAMUR NE 107, NMI (Netherlands)
Tank Database Capacity80 tanks (one gauge per tank), 40 tanks (two gauges per tank)
Supported GaugesAll GPU-Enabled Tank Gauges (811, 813, 866, 854, 872, 873, 877, 894, 990, 954) and Emerson TRL/2
Relative Humidity0 to 90% RH (Non-Condensing)
RedundancyHot Standby, Real-Time Synchronization; Redundant Ethernet Ports (redundancy controlled by Entis or modbus host)
Protocols SupportedModbus TCP/IP, OPC UA TCP, Serial Modbus, CIU 858/880 Emulation, Enraf BPM Fieldbus, TRL/2 Fieldbus, RS-232/RS-485
Host ConnectivityEthernet/LAN-3X Modbus TCP/IP ethernet (FTEA, FTEB and Office LAN); Serial Ports-2X modbus serial (+ 4 additional ports by using optional slots)
Field ConnectivityAvailable Option Boards - Enraf BPM fieldbus, Serial modbus (master) and Serial GPU input and TRL/2 Fieldbus; Field Ports - 6X option slots (of which 4 ports can be used for serial host connectivity); Wireless Connectivity - ISA 100 via Honeywell WDM through TCP/IP to serial converters
Power Supply100 to 240 VAC, Auto-Ranging (-15 to +10%), 45 to 65 Hz, max 60 VA (35 VA Nominal)
Operating SystemLinux Arch, 4 GB Flash Memory (Upgradable)
MountingWall, Rack, or Tabletop
FunctionField scanning and communication interface for tank inventory applications with Optional embedded tank inventory calculation functionality
EnclosureIP30 (NEMA 1)
Dimensions400 x 93 x 283 mm (15-3/4 x 3-3/4 x 11-1/4 in)
ApplicationsFor all applications requiring accurate and reliable process and inventory data, such as refineries, tank farms and terminals. Data is suitable for custody transfer, safe product transfer and tank farm operation.
User InterfaceLCD Color Display (50 x 38 mm, 320 x 240 px), Navigation Keys, LED Ring for Status, Key Lock Switches for Config/W&M Sealing

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published model / variant identifiers. A full ordering code requires the manufacturer configuration.

Published part numbers

2 parts

Part NumberDescriptionEnquiry
F888CIU 888 FunctionalityRequest quotation
H888CIU 888 HardwareRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/terminals/enraf-tank-gauging/communication-interface-unit-ciu888

Last source check: 2026-11-02

Communication Interface Unit (CIU888) Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.