Enraf Tank Gauging
Communication Interface Unit (CIU888)
CIU888 connects tank gauges with inventory and operating applications at bulk-storage sites.
CIU888 connects tank gauges with inventory and operating applications at bulk-storage sites. It gathers and processes field information, making measured and calculated values available to different users and supporting custody-transfer reporting. Commissioning and remote-service tools help maintain the connected gauges, while the gateway provides a common path between tank instrumentation and terminal information systems.
Models: CIU888
Features & Benefits
- Role
- Tank-gauge communication and inventory-data gateway
- Makes tank data available to multiple operational users
Applications
- Tank farms
- Bulk storage
- Custody-transfer reporting
Detailed capabilities
Product and configuration
CIU888 connects tank gauges with inventory and operating applications at bulk-storage sites. It gathers and processes field information, making measured and calculated values available to different users and supporting custody-transfer reporting. Commissioning and remote-service tools help maintain the connected gauges, while the gateway provides a common path between tank instrumentation and terminal information systems.
- Role: Tank-gauge communication and inventory-data gateway
Operation and integration
CIU888 continuously scans connected gauges and calculates tank inventory using the described API/ASTM methods. Legacy serial connections can retain existing applications, while Ethernet provides additional access. Continuously synchronized redundant units maintain data status and validity for Weights and Measures purposes. A Ring of Light and LCD give local status, and web diagnostics support remote service and analysis.
Application and selection
The gateway makes measured and calculated inventory information available for product movements, custody reporting and operational monitoring. Its redundancy, security and calculation arrangements belong to the configured CIU system. The page's authority and standards references should be matched to the selected custody-transfer installation rather than assumed for every connected application.
Environmental Safety
- Ambient Temperature Range
- 0 to +60 deg C (32 to 140 deg F)
- Storage Temperature Range
- -20 to 85 deg C (-4 to 185 deg F)
- Approvals
- IEC 61010-1:2010, EN 61010-1:2010, CE, CAN/CSA, UL Std. 61010-1, NAMUR NE 107, NMI (Netherlands)
I/O Capabilities
- Tank Database Capacity
- 80 tanks (one gauge per tank), 40 tanks (two gauges per tank)
Device & Network Capacity
- Supported Gauges
- All GPU-Enabled Tank Gauges (811, 813, 866, 854, 872, 873, 877, 894, 990, 954) and Emerson TRL/2
Environmental Conditions
- Relative Humidity
- 0 to 90% RH (Non-Condensing)
Redundancy & Synchronization
- Redundancy
- Hot Standby, Real-Time Synchronization; Redundant Ethernet Ports (redundancy controlled by Entis or modbus host)
Communication & Protocols
- Protocols Supported
- Modbus TCP/IP, OPC UA TCP, Serial Modbus, CIU 858/880 Emulation, Enraf BPM Fieldbus, TRL/2 Fieldbus, RS-232/RS-485
- Host Connectivity
- Ethernet/LAN-3X Modbus TCP/IP ethernet (FTEA, FTEB and Office LAN); Serial Ports-2X modbus serial (+ 4 additional ports by using optional slots)
- Field Connectivity
- Available Option Boards - Enraf BPM fieldbus, Serial modbus (master) and Serial GPU input and TRL/2 Fieldbus; Field Ports - 6X option slots (of which 4 ports can be used for serial host connectivity); Wireless Connectivity - ISA 100 via Honeywell WDM through TCP/IP to serial converters
Electrical
- Power Supply
- 100 to 240 VAC, Auto-Ranging (-15 to +10%), 45 to 65 Hz, max 60 VA (35 VA Nominal)
Software & Interface
- Operating System
- Linux Arch, 4 GB Flash Memory (Upgradable)
VITO Interface
- Mounting
- Wall, Rack, or Tabletop
Technical Specifications
- Function
- Field scanning and communication interface for tank inventory applications with Optional embedded tank inventory calculation functionality
Mechanical & Physical Properties
- Enclosure
- IP30 (NEMA 1)
Mechanical
- Dimensions
- 400 x 93 x 283 mm (15-3/4 x 3-3/4 x 11-1/4 in)
Applications & Compatibility
- Applications
- For all applications requiring accurate and reliable process and inventory data, such as refineries, tank farms and terminals. Data is suitable for custody transfer, safe product transfer and tank farm operation.
Others
- User Interface
- LCD Color Display (50 x 38 mm, 320 x 240 px), Navigation Keys, LED Ring for Status, Key Lock Switches for Config/W&M Sealing
| Parameter | Published value / configuration |
|---|---|
| Ambient Temperature Range | 0 to +60 deg C (32 to 140 deg F) |
| Storage Temperature Range | -20 to 85 deg C (-4 to 185 deg F) |
| Approvals | IEC 61010-1:2010, EN 61010-1:2010, CE, CAN/CSA, UL Std. 61010-1, NAMUR NE 107, NMI (Netherlands) |
| Tank Database Capacity | 80 tanks (one gauge per tank), 40 tanks (two gauges per tank) |
| Supported Gauges | All GPU-Enabled Tank Gauges (811, 813, 866, 854, 872, 873, 877, 894, 990, 954) and Emerson TRL/2 |
| Relative Humidity | 0 to 90% RH (Non-Condensing) |
| Redundancy | Hot Standby, Real-Time Synchronization; Redundant Ethernet Ports (redundancy controlled by Entis or modbus host) |
| Protocols Supported | Modbus TCP/IP, OPC UA TCP, Serial Modbus, CIU 858/880 Emulation, Enraf BPM Fieldbus, TRL/2 Fieldbus, RS-232/RS-485 |
| Host Connectivity | Ethernet/LAN-3X Modbus TCP/IP ethernet (FTEA, FTEB and Office LAN); Serial Ports-2X modbus serial (+ 4 additional ports by using optional slots) |
| Field Connectivity | Available Option Boards - Enraf BPM fieldbus, Serial modbus (master) and Serial GPU input and TRL/2 Fieldbus; Field Ports - 6X option slots (of which 4 ports can be used for serial host connectivity); Wireless Connectivity - ISA 100 via Honeywell WDM through TCP/IP to serial converters |
| Power Supply | 100 to 240 VAC, Auto-Ranging (-15 to +10%), 45 to 65 Hz, max 60 VA (35 VA Nominal) |
| Operating System | Linux Arch, 4 GB Flash Memory (Upgradable) |
| Mounting | Wall, Rack, or Tabletop |
| Function | Field scanning and communication interface for tank inventory applications with Optional embedded tank inventory calculation functionality |
| Enclosure | IP30 (NEMA 1) |
| Dimensions | 400 x 93 x 283 mm (15-3/4 x 3-3/4 x 11-1/4 in) |
| Applications | For all applications requiring accurate and reliable process and inventory data, such as refineries, tank farms and terminals. Data is suitable for custody transfer, safe product transfer and tank farm operation. |
| User Interface | LCD Color Display (50 x 38 mm, 320 x 240 px), Navigation Keys, LED Ring for Status, Key Lock Switches for Config/W&M Sealing |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published model / variant identifiers. A full ordering code requires the manufacturer configuration.
Published part numbers
2 parts
| Part Number | Description | Enquiry |
|---|---|---|
| F888 | CIU 888 Functionality | Request quotation |
| H888 | CIU 888 Hardware | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Communication Interface Unit (CIU888) Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.
