Smart Servo 954 measures liquids in storage tanks using servo-gauging technology with updated electronics and algorithms.

Smart Servo 954 measures liquids in storage tanks using servo-gauging technology with updated electronics and algorithms. Its modular design lets users choose functions for the application, including demanding liquid or vaporized-liquid duties and extended measurement conditions. The gauge continues Honeywell's servo portfolio, providing automated level information for tank farms and terminals where inventory measurement requires reliable operation.

Features & Benefits

Architecture
Modular servo tank gauge
  • Supports selection of options for demanding tank duties

Applications

  • Liquid and vaporized-liquid storage tanks
  • Tank farms and terminals

Detailed capabilities

Product and configuration

Smart Servo 954 measures liquids in storage tanks using servo-gauging technology with updated electronics and algorithms. Its modular design lets users choose functions for the application, including demanding liquid or vaporized-liquid duties and extended measurement conditions. The gauge continues Honeywell's servo portfolio, providing automated level information for tank farms and terminals where inventory measurement requires reliable operation.

  • Architecture: Modular servo tank gauge

Manufacturer reference ↗

Operation and integration

Servo 954 combines servo-level measurement with options for interface, density, temperature and water-bottom information. Spot or average temperature and profiling are described, along with direct or capacitive water-bottom measurement and pressure-transmitter-based density monitoring. SIL-certified relay or analogue outputs provide the documented connection to suitable control or overfill systems. Modular assemblies support maintenance and migration.

Manufacturer reference ↗

Application and selection

Published envelope limits reach 150 metres and 40 bar, but measurement, pressure and output options must be selected together. The device can serve liquid and vaporized-liquid storage under dynamic conditions. The range of functions is a portfolio of configured capabilities, not a statement that every ordered gauge contains every associated sensor or safety output.

Manufacturer reference ↗

Case studies & further resources

Manufacturer Document

2212200 HPS CAS Valero Dublin Customer Success Story A4

View resource ↗

Specifications

Environmental Safety

Ambient Temperature Range
-40 to +65 deg C (-40 to +149 deg F)
Storage Temperature Range
-50 to +70 deg C (-58 to +158 deg F)
Protection Class
IP6 /IP67 according to EN 60529 (NEMA 4X)
Explosion Safety Approvals
• Explosion proof; −Class I, Division 1, Group C & D (FM); −Class I, Group C & D (CSA certificate); −Ex d [ia Ga] IIB T6 Ga/Gb or Ex de [ia Ga] IIB T6 Ga/Gb (ATEX KEMA); −II 1/2 G Ex d IIB T6 Ga/Gb or Ex de IIB T6 Ga/Gb
Approvals
SIL-by-design (IEC 61508), ATEX, IECEx, FM, CSA, KOSHA, INMETRO, NMi, OIML R85

Mechanical

Weight
Chemical version -21 kg (46 lb); High pressure version -26 kg (57 lb); Medium pressure version -16 kg (35 lb)
Flange Specification
Chemical version, 2 in Class 150 RF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 μm), AISI 316, Up to 6 bar; Chemical version, DN50, PN 6, Flanges acc. EN 1092-1, (Ra=3.2-12.5 μm), AISI 316, Up to 6 bar; High pressure, 2 in Class 300 RF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 μm), AISI 316, Up to 40 Bar; High pressure, DN50, PN 40, Flanges acc. EN 1092-1, (Ra=3.2-12.5 μm), AISI 316, Up to 40 Bar; Medium pressure, 2 in Class 150 FF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 μm), AL, Up to 6 Bar; • Atmospheric pressure, 2 in Class 150 FF, Flanges acc. ASME B16.5, (Ra = 3.2-6.3 μm) , AL
Cable Entries
4 x ¾ in NPT (2* I.S. + 2* non-I.S.)

Instrument Measuring Specification

Sensitivity
≤ 0.1 mm (±0.004 in)
Repeatability
≤ 0.1 mm (±0.004 in)
Process Temperature Range
Max -+200 deg C (+392 deg F), drum housing must be kept below +65 deg C (+149 deg F); Min -200 deg C (-328 deg F), drum housing must be kept above -40 deg C (-40 deg F)
Process Pressure Range
H version Up to 40 bar/4 MPa (600 psi) (up to 25 bar/2.5 MPa in acc. to PED); M and C versions -Up to 6 bar/0.6 MPa (90 psi)
Measuring Accuracy
Density: < ±3 kg/m³ (±0.19 lb/ft³); Interface: < ±2 mm (±0.08 in); Level :40 m: < ±0.4 mm (±0.016 in), OIML R85 certified, 45 m: ±1 mm; Temperature: < ±0.1 deg C (±0.18 deg F)
Level Measuring Range
• Standard: 27 m (88 ft) • Extended: -37 m (121 ft), 40 m (131 ft) - 45 m (147 ft), - 35 m (115 ft) with measuring wire up to 150 m (492 ft)• Longer ranges available on request
Density
Available with density firmware and density displacer

Electrical

Power Supply
Autoselect 65 to 240 VAC, 50/60 Hz and/or 24 to 65 VDC
Power Rating
11 Wmax continuously

Process Wetted Materials

O-Ring Material
Chemical applications (such as Ammonia), part nr. S0854969; Drum cover Silicone/FEP; others FPN (Viton®); Special O-ring (Perlas®) available for demanding
Measuring Wire
Measuring range - 27 M, Wire Material -AISI 316, Hestelloy C22, Tantalum, Tungsten; Measuring range - 37 M, Wire Material -AISI 316, Invar, Tungsten; Measuring range - 40 M/45 M, Aviallable Wire Material -AISI 316, Tungsten
Measuring Drum/Drum Shaft
Stainless Steel (1.4401) EN10088 AISI 316
Magnet Cap
Stainless Steel (1.4401) EN10088 AISI 316
Drum Compartment
Cast Aluminum Int. reg. AA A356 EN1706 AC-AlSi7Mg0.3; Stainless Steel ASTM A351, CF-8M, G-X6 CrNiMo 18 10 (1.4408)

Migration Option

Migration Option
• Enraf Servo 854 ATG to Servo 954 hardware migration/upgrade kit

General

Measurement Capabilities
Product Level, Interface Level, Density, Water Bottom, Temperature (Spot/Average/Profile)

Data Communication & Inputs

Inputs
VITO Temperature/Water Probe, Spot RTD (up to 6 elements), HART® Inputs (up to 5)
Communication
Honeywell Bi-phase Mark, TRL/2, Modbus RTU, HART® 7, ASCII, GPU Protocol

SIL 2/3 Safety Function Output Options

Digital and Analog Combined
SIL AO + 1 SIL DO contact NAMUR NE43 compliant, (1 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W); SIL AO + 2 SIL DO contacts NAMUR NE43 compliant, (2 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W)
Digital Output Specification
1 x SIL DO contact (1 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W); 2 x SIL DO contact (2 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W)
Analog Output Specification
SIL AO NAMUR NE43 compliant
Enraf Servo 954 — manufacturer page values
ParameterPublished value / configuration
Ambient Temperature Range-40 to +65 deg C (-40 to +149 deg F)
Storage Temperature Range-50 to +70 deg C (-58 to +158 deg F)
Protection ClassIP6 /IP67 according to EN 60529 (NEMA 4X)
Explosion Safety Approvals• Explosion proof; −Class I, Division 1, Group C & D (FM); −Class I, Group C & D (CSA certificate); −Ex d [ia Ga] IIB T6 Ga/Gb or Ex de [ia Ga] IIB T6 Ga/Gb (ATEX KEMA); −II 1/2 G Ex d IIB T6 Ga/Gb or Ex de IIB T6 Ga/Gb
ApprovalsSIL-by-design (IEC 61508), ATEX, IECEx, FM, CSA, KOSHA, INMETRO, NMi, OIML R85
WeightChemical version -21 kg (46 lb); High pressure version -26 kg (57 lb); Medium pressure version -16 kg (35 lb)
Flange SpecificationChemical version, 2 in Class 150 RF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 μm), AISI 316, Up to 6 bar; Chemical version, DN50, PN 6, Flanges acc. EN 1092-1, (Ra=3.2-12.5 μm), AISI 316, Up to 6 bar; High pressure, 2 in Class 300 RF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 μm), AISI 316, Up to 40 Bar; High pressure, DN50, PN 40, Flanges acc. EN 1092-1, (Ra=3.2-12.5 μm), AISI 316, Up to 40 Bar; Medium pressure, 2 in Class 150 FF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 μm), AL, Up to 6 Bar; • Atmospheric pressure, 2 in Class 150 FF, Flanges acc. ASME B16.5, (Ra = 3.2-6.3 μm) , AL
Cable Entries4 x ¾ in NPT (2* I.S. + 2* non-I.S.)
Sensitivity≤ 0.1 mm (±0.004 in)
Repeatability≤ 0.1 mm (±0.004 in)
Process Temperature RangeMax -+200 deg C (+392 deg F), drum housing must be kept below +65 deg C (+149 deg F); Min -200 deg C (-328 deg F), drum housing must be kept above -40 deg C (-40 deg F)
Process Pressure RangeH version Up to 40 bar/4 MPa (600 psi) (up to 25 bar/2.5 MPa in acc. to PED); M and C versions -Up to 6 bar/0.6 MPa (90 psi)
Measuring AccuracyDensity: < ±3 kg/m³ (±0.19 lb/ft³); Interface: < ±2 mm (±0.08 in); Level :40 m: < ±0.4 mm (±0.016 in), OIML R85 certified, 45 m: ±1 mm; Temperature: < ±0.1 deg C (±0.18 deg F)
Level Measuring Range• Standard: 27 m (88 ft) • Extended: -37 m (121 ft), 40 m (131 ft) - 45 m (147 ft), - 35 m (115 ft) with measuring wire up to 150 m (492 ft)• Longer ranges available on request
DensityAvailable with density firmware and density displacer
Power SupplyAutoselect 65 to 240 VAC, 50/60 Hz and/or 24 to 65 VDC
Power Rating11 Wmax continuously
O-Ring MaterialChemical applications (such as Ammonia), part nr. S0854969; Drum cover Silicone/FEP; others FPN (Viton®); Special O-ring (Perlas®) available for demanding
Measuring WireMeasuring range - 27 M, Wire Material -AISI 316, Hestelloy C22, Tantalum, Tungsten; Measuring range - 37 M, Wire Material -AISI 316, Invar, Tungsten; Measuring range - 40 M/45 M, Aviallable Wire Material -AISI 316, Tungsten
Measuring Drum/Drum ShaftStainless Steel (1.4401) EN10088 AISI 316
Magnet CapStainless Steel (1.4401) EN10088 AISI 316
Drum CompartmentCast Aluminum Int. reg. AA A356 EN1706 AC-AlSi7Mg0.3; Stainless Steel ASTM A351, CF-8M, G-X6 CrNiMo 18 10 (1.4408)
Migration Option• Enraf Servo 854 ATG to Servo 954 hardware migration/upgrade kit
Measurement CapabilitiesProduct Level, Interface Level, Density, Water Bottom, Temperature (Spot/Average/Profile)
InputsVITO Temperature/Water Probe, Spot RTD (up to 6 elements), HART® Inputs (up to 5)
CommunicationHoneywell Bi-phase Mark, TRL/2, Modbus RTU, HART® 7, ASCII, GPU Protocol
Digital and Analog CombinedSIL AO + 1 SIL DO contact NAMUR NE43 compliant, (1 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W); SIL AO + 2 SIL DO contacts NAMUR NE43 compliant, (2 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W)
Digital Output Specification1 x SIL DO contact (1 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W); 2 x SIL DO contact (2 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W)
Analog Output SpecificationSIL AO NAMUR NE43 compliant

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Resources

Filter documents by type

Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.

Honeywell resource listing ↗

Part Number

Published part numbers

2 parts

Part NumberDescriptionEnquiry
954ASmartServo FlexLineRequest quotation
U0690628UPGRADE BPM AND BT KITRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/terminals/enraf-tank-gauging/enraf-servo-954

Last source check: 2026-11-02

Enraf Servo 954 Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry