Enraf Tank Gauging
Enraf Servo 954
Smart Servo 954 measures liquids in storage tanks using servo-gauging technology with updated electronics and algorithms.
Smart Servo 954 measures liquids in storage tanks using servo-gauging technology with updated electronics and algorithms. Its modular design lets users choose functions for the application, including demanding liquid or vaporized-liquid duties and extended measurement conditions. The gauge continues Honeywell's servo portfolio, providing automated level information for tank farms and terminals where inventory measurement requires reliable operation.
Features & Benefits
- Architecture
- Modular servo tank gauge
- Supports selection of options for demanding tank duties
Applications
- Liquid and vaporized-liquid storage tanks
- Tank farms and terminals
Detailed capabilities
Product and configuration
Smart Servo 954 measures liquids in storage tanks using servo-gauging technology with updated electronics and algorithms. Its modular design lets users choose functions for the application, including demanding liquid or vaporized-liquid duties and extended measurement conditions. The gauge continues Honeywell's servo portfolio, providing automated level information for tank farms and terminals where inventory measurement requires reliable operation.
- Architecture: Modular servo tank gauge
Operation and integration
Servo 954 combines servo-level measurement with options for interface, density, temperature and water-bottom information. Spot or average temperature and profiling are described, along with direct or capacitive water-bottom measurement and pressure-transmitter-based density monitoring. SIL-certified relay or analogue outputs provide the documented connection to suitable control or overfill systems. Modular assemblies support maintenance and migration.
Application and selection
Published envelope limits reach 150 metres and 40 bar, but measurement, pressure and output options must be selected together. The device can serve liquid and vaporized-liquid storage under dynamic conditions. The range of functions is a portfolio of configured capabilities, not a statement that every ordered gauge contains every associated sensor or safety output.
Environmental Safety
- Ambient Temperature Range
- -40 to +65 deg C (-40 to +149 deg F)
- Storage Temperature Range
- -50 to +70 deg C (-58 to +158 deg F)
- Protection Class
- IP6 /IP67 according to EN 60529 (NEMA 4X)
- Explosion Safety Approvals
- • Explosion proof; −Class I, Division 1, Group C & D (FM); −Class I, Group C & D (CSA certificate); −Ex d [ia Ga] IIB T6 Ga/Gb or Ex de [ia Ga] IIB T6 Ga/Gb (ATEX KEMA); −II 1/2 G Ex d IIB T6 Ga/Gb or Ex de IIB T6 Ga/Gb
- Approvals
- SIL-by-design (IEC 61508), ATEX, IECEx, FM, CSA, KOSHA, INMETRO, NMi, OIML R85
Mechanical
- Weight
- Chemical version -21 kg (46 lb); High pressure version -26 kg (57 lb); Medium pressure version -16 kg (35 lb)
- Flange Specification
- Chemical version, 2 in Class 150 RF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 μm), AISI 316, Up to 6 bar; Chemical version, DN50, PN 6, Flanges acc. EN 1092-1, (Ra=3.2-12.5 μm), AISI 316, Up to 6 bar; High pressure, 2 in Class 300 RF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 μm), AISI 316, Up to 40 Bar; High pressure, DN50, PN 40, Flanges acc. EN 1092-1, (Ra=3.2-12.5 μm), AISI 316, Up to 40 Bar; Medium pressure, 2 in Class 150 FF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 μm), AL, Up to 6 Bar; • Atmospheric pressure, 2 in Class 150 FF, Flanges acc. ASME B16.5, (Ra = 3.2-6.3 μm) , AL
- Cable Entries
- 4 x ¾ in NPT (2* I.S. + 2* non-I.S.)
Instrument Measuring Specification
- Sensitivity
- ≤ 0.1 mm (±0.004 in)
- Repeatability
- ≤ 0.1 mm (±0.004 in)
- Process Temperature Range
- Max -+200 deg C (+392 deg F), drum housing must be kept below +65 deg C (+149 deg F); Min -200 deg C (-328 deg F), drum housing must be kept above -40 deg C (-40 deg F)
- Process Pressure Range
- H version Up to 40 bar/4 MPa (600 psi) (up to 25 bar/2.5 MPa in acc. to PED); M and C versions -Up to 6 bar/0.6 MPa (90 psi)
- Measuring Accuracy
- Density: < ±3 kg/m³ (±0.19 lb/ft³); Interface: < ±2 mm (±0.08 in); Level :40 m: < ±0.4 mm (±0.016 in), OIML R85 certified, 45 m: ±1 mm; Temperature: < ±0.1 deg C (±0.18 deg F)
- Level Measuring Range
- • Standard: 27 m (88 ft) • Extended: -37 m (121 ft), 40 m (131 ft) - 45 m (147 ft), - 35 m (115 ft) with measuring wire up to 150 m (492 ft)• Longer ranges available on request
- Density
- Available with density firmware and density displacer
Electrical
- Power Supply
- Autoselect 65 to 240 VAC, 50/60 Hz and/or 24 to 65 VDC
- Power Rating
- 11 Wmax continuously
Process Wetted Materials
- O-Ring Material
- Chemical applications (such as Ammonia), part nr. S0854969; Drum cover Silicone/FEP; others FPN (Viton®); Special O-ring (Perlas®) available for demanding
- Measuring Wire
- Measuring range - 27 M, Wire Material -AISI 316, Hestelloy C22, Tantalum, Tungsten; Measuring range - 37 M, Wire Material -AISI 316, Invar, Tungsten; Measuring range - 40 M/45 M, Aviallable Wire Material -AISI 316, Tungsten
- Measuring Drum/Drum Shaft
- Stainless Steel (1.4401) EN10088 AISI 316
- Magnet Cap
- Stainless Steel (1.4401) EN10088 AISI 316
- Drum Compartment
- Cast Aluminum Int. reg. AA A356 EN1706 AC-AlSi7Mg0.3; Stainless Steel ASTM A351, CF-8M, G-X6 CrNiMo 18 10 (1.4408)
Migration Option
- Migration Option
- • Enraf Servo 854 ATG to Servo 954 hardware migration/upgrade kit
General
- Measurement Capabilities
- Product Level, Interface Level, Density, Water Bottom, Temperature (Spot/Average/Profile)
Data Communication & Inputs
- Inputs
- VITO Temperature/Water Probe, Spot RTD (up to 6 elements), HART® Inputs (up to 5)
- Communication
- Honeywell Bi-phase Mark, TRL/2, Modbus RTU, HART® 7, ASCII, GPU Protocol
SIL 2/3 Safety Function Output Options
- Digital and Analog Combined
- SIL AO + 1 SIL DO contact NAMUR NE43 compliant, (1 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W); SIL AO + 2 SIL DO contacts NAMUR NE43 compliant, (2 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W)
- Digital Output Specification
- 1 x SIL DO contact (1 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W); 2 x SIL DO contact (2 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W)
- Analog Output Specification
- SIL AO NAMUR NE43 compliant
| Parameter | Published value / configuration |
|---|---|
| Ambient Temperature Range | -40 to +65 deg C (-40 to +149 deg F) |
| Storage Temperature Range | -50 to +70 deg C (-58 to +158 deg F) |
| Protection Class | IP6 /IP67 according to EN 60529 (NEMA 4X) |
| Explosion Safety Approvals | • Explosion proof; −Class I, Division 1, Group C & D (FM); −Class I, Group C & D (CSA certificate); −Ex d [ia Ga] IIB T6 Ga/Gb or Ex de [ia Ga] IIB T6 Ga/Gb (ATEX KEMA); −II 1/2 G Ex d IIB T6 Ga/Gb or Ex de IIB T6 Ga/Gb |
| Approvals | SIL-by-design (IEC 61508), ATEX, IECEx, FM, CSA, KOSHA, INMETRO, NMi, OIML R85 |
| Weight | Chemical version -21 kg (46 lb); High pressure version -26 kg (57 lb); Medium pressure version -16 kg (35 lb) |
| Flange Specification | Chemical version, 2 in Class 150 RF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 μm), AISI 316, Up to 6 bar; Chemical version, DN50, PN 6, Flanges acc. EN 1092-1, (Ra=3.2-12.5 μm), AISI 316, Up to 6 bar; High pressure, 2 in Class 300 RF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 μm), AISI 316, Up to 40 Bar; High pressure, DN50, PN 40, Flanges acc. EN 1092-1, (Ra=3.2-12.5 μm), AISI 316, Up to 40 Bar; Medium pressure, 2 in Class 150 FF, Flanges acc. ASME B16.5, (Ra=3.2-6.3 μm), AL, Up to 6 Bar; • Atmospheric pressure, 2 in Class 150 FF, Flanges acc. ASME B16.5, (Ra = 3.2-6.3 μm) , AL |
| Cable Entries | 4 x ¾ in NPT (2* I.S. + 2* non-I.S.) |
| Sensitivity | ≤ 0.1 mm (±0.004 in) |
| Repeatability | ≤ 0.1 mm (±0.004 in) |
| Process Temperature Range | Max -+200 deg C (+392 deg F), drum housing must be kept below +65 deg C (+149 deg F); Min -200 deg C (-328 deg F), drum housing must be kept above -40 deg C (-40 deg F) |
| Process Pressure Range | H version Up to 40 bar/4 MPa (600 psi) (up to 25 bar/2.5 MPa in acc. to PED); M and C versions -Up to 6 bar/0.6 MPa (90 psi) |
| Measuring Accuracy | Density: < ±3 kg/m³ (±0.19 lb/ft³); Interface: < ±2 mm (±0.08 in); Level :40 m: < ±0.4 mm (±0.016 in), OIML R85 certified, 45 m: ±1 mm; Temperature: < ±0.1 deg C (±0.18 deg F) |
| Level Measuring Range | • Standard: 27 m (88 ft) • Extended: -37 m (121 ft), 40 m (131 ft) - 45 m (147 ft), - 35 m (115 ft) with measuring wire up to 150 m (492 ft)• Longer ranges available on request |
| Density | Available with density firmware and density displacer |
| Power Supply | Autoselect 65 to 240 VAC, 50/60 Hz and/or 24 to 65 VDC |
| Power Rating | 11 Wmax continuously |
| O-Ring Material | Chemical applications (such as Ammonia), part nr. S0854969; Drum cover Silicone/FEP; others FPN (Viton®); Special O-ring (Perlas®) available for demanding |
| Measuring Wire | Measuring range - 27 M, Wire Material -AISI 316, Hestelloy C22, Tantalum, Tungsten; Measuring range - 37 M, Wire Material -AISI 316, Invar, Tungsten; Measuring range - 40 M/45 M, Aviallable Wire Material -AISI 316, Tungsten |
| Measuring Drum/Drum Shaft | Stainless Steel (1.4401) EN10088 AISI 316 |
| Magnet Cap | Stainless Steel (1.4401) EN10088 AISI 316 |
| Drum Compartment | Cast Aluminum Int. reg. AA A356 EN1706 AC-AlSi7Mg0.3; Stainless Steel ASTM A351, CF-8M, G-X6 CrNiMo 18 10 (1.4408) |
| Migration Option | • Enraf Servo 854 ATG to Servo 954 hardware migration/upgrade kit |
| Measurement Capabilities | Product Level, Interface Level, Density, Water Bottom, Temperature (Spot/Average/Profile) |
| Inputs | VITO Temperature/Water Probe, Spot RTD (up to 6 elements), HART® Inputs (up to 5) |
| Communication | Honeywell Bi-phase Mark, TRL/2, Modbus RTU, HART® 7, ASCII, GPU Protocol |
| Digital and Analog Combined | SIL AO + 1 SIL DO contact NAMUR NE43 compliant, (1 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W); SIL AO + 2 SIL DO contacts NAMUR NE43 compliant, (2 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W) |
| Digital Output Specification | 1 x SIL DO contact (1 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W); 2 x SIL DO contact (2 x SPDT contact, 2 A at 250 Vac or 2 A at 40 Vdc, Pmax = 500 W) |
| Analog Output Specification | SIL AO NAMUR NE43 compliant |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
2 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 954A | SmartServo FlexLine | Request quotation |
| U0690628 | UPGRADE BPM AND BT KIT | Request quotation |
Manufacturer sources
https://process.honeywell.com/us/en/products/terminals/enraf-tank-gauging/enraf-servo-954
Last source check: 2026-11-02
Enraf Servo 954 Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.
