Enraf Tank Gauging
Enraf Flexline Radar 990
Enraf FlexLine radar gauges combine signal-processing software with planar antenna designs for bulk-storage level measurement.
Enraf FlexLine radar gauges combine signal-processing software with planar antenna designs for bulk-storage level measurement. Free-space and stilling-well antenna choices address different tank installations, including difficult geometry or echoes. The automatic gauge serves inventory and custody-transfer duties at refineries, terminals and petrochemical sites, with configuration selected around the tank and antenna arrangement.
Features & Benefits
- Antenna arrangements
- Free space or stilling well
- Supports measurements in difficult tank installations
Applications
- Bulk-storage inventory
- Custody transfer
- Refineries and terminals
Detailed capabilities
Product and configuration
Enraf FlexLine radar gauges combine signal-processing software with planar antenna designs for bulk-storage level measurement. Free-space and stilling-well antenna choices address different tank installations, including difficult geometry or echoes. The automatic gauge serves inventory and custody-transfer duties at refineries, terminals and petrochemical sites, with configuration selected around the tank and antenna arrangement.
- Antenna arrangements: Free space or stilling well
Operation and integration
SmartRadar FlexLine combines planar antennas with enhanced signal processing to interpret echoes in difficult tanks, including locations near the shell or with problematic roofs and stilling wells. Additional diagnostics and the published board-voting arrangement detect and isolate failures. Free-space and stilling-well antenna selections address different installation geometries; a wireless option can reduce separate field cabling.
Application and selection
The source identifies inventory/custody measurement and dedicated duties such as overfill protection or floating-roof monitoring. Its SIL2/SIL3 claims apply to the approved safety configuration, not automatically to any inventory gauge installed with any antenna. Select the antenna, independent protective function and certificate against the actual tank application.
Environmental Safety
- Ambient Temperature Range
- -40 to +65 °C (-40 to +149 °F)
- Storage Temperature Range
- -50 to +75 °C (-58 to +167 °F)
- Explosion Safety Approvals
- ATEX KEMA, IECEx KEMA, Kosha, FM, CSA, INMETRO TÜV
Explosion Safety & Legal Metrology Approvals
- Weights & Measures
- NMi, PTB, BRML, UMI, LNE, DZM, ONML, W&M India, PAC, MIGAS, OIML, and several others
- Other Approvals/Certificates
- NEPSI, PESO (India), GOST-Rx
- Ingress Protection
- IP66/IP67 (NEMA 4X)
Mechanical
- Weight
- ≈16 kg (35 lb), depending on installed options and excluding antenna and tank separator
- Dimensions
- 217 x 319 x 379 mm (8.55 in x 12.55 in x 14.9 in) (H x W x L)
- Cable Entries
- 3 x 3/4 in NPT *6 or 6 x M20
Measuring Specifications
- Update Time
- 0.1 sec
- Measuring Resolution
- 0.1 mm (0.001 in)
- Measuring Range
- Up to 75 m (246 ft)
- Instrument Accuracy Level
- Advanced performance SmartRadar ±3 mm (±0.12 in); High performance SmartRadar ±1 mm (±0.04 in); Xtreme performance SmartRadar ±0.4 mm (±0.016 in)
Process Wetted Materials
- Tank Separator
- AISI 316 Stainless Steel (Material no.: 1.4401); O-Rings Material FPM
- O-Ring Material
- NBR 70
- Antenna Materials
- Ball Valve (optional with horn antenna): Stainless Steel CF8M (mat no.: 1.4408); High Pressure Horn Antennas: SS AISI 316 (mat. no.:1.4401) and PTFE (in high pressure tank separator); Planar (PAT) Antennas: SS AISI 316 (mat. no.: 1.4401) and FEP
General
- Signal Processing
- Fully digital using Enhanced Performance Signal Processing (EPSP)
- Operating Frequency
- Xband (9.538 GHz to 10.561 GHz) R&TTE, FCC compliant
- Measuring Principle
- FMCW/Synthesized Reflectometer
Functional Safety And Overfill Prevention
- SIL Certification
- TÜV certified for SIL 2 and SIL 3
- Overfill Protection
- DIBt WHG, Corcon BVBA
Instrument Measuring Specification
- Process Temperature Range
- -200 to +250 deg C (-328 to +482 deg F)
- Process Pressure Range
- Horn Antennas: up to 40 bar/4 MPa (580 psi); Planar (PAT) Antennas: up to 6 bar/0.6 MPa (87 psi)
Electrical
- Power Supply
- Autoselect 65 Vac to 240 Vac (+10% to -15%) 50/60 Hz and/or 24 Vdc to 65 Vdc (+10% to -15%)
- Power Rating
- Typical 15 W; max. 23 W with all options
- Maximum Current
- Imax = 1.2 A (start-up)
Enclosure Materials
- Material Finish
- Hard anodized according to MIL A8625-E Type III
- Instrument Housing
- Cast aluminum alloy according to EN1706, AA A356 EN1706, AC-AlSi7Mg0.3
- Cover
- Aluminum; coating: Polyurethane
Data Communication & Inputs
- Inputs
- VITO Temperature/Water Probe, Spot RTD (3 wire or 4 wire RTD, one or 2 element), (MPT/MRT up to 6 elements), HART® Inputs
SIL 2/3 Safety Function Output Options
- Digital and Analog Combined
- SIL AO + 1 SIL DO + 1 SIL DO contact; SIL AO + 2 SIL DO Contact
- Digital Output Specification
- 1x SIL DO contact (1x SPDT contact, 2A at 250 Vac or 2 A at 40 Vdc, Pmax= 500 W); 2x SIL DO contact (2x SPDT contact, 2A at 250 Vac or 2 A at 40 Vdc, Pmax= 500 W)
- Analog Output Specification
- SIL AO NAMUR NE43 compliant
VITO Interface
- Data Communication
- Enraf Fieldbus (BPM), TRL/2, Modbus RTU, HART® Slave-Multidrop/or 4-20 mA, RS-232/RS-485 GPU Protocol, Wireless (ISA100/IEC62734)
| Parameter | Published value / configuration |
|---|---|
| Ambient Temperature Range | -40 to +65 °C (-40 to +149 °F) |
| Storage Temperature Range | -50 to +75 °C (-58 to +167 °F) |
| Explosion Safety Approvals | ATEX KEMA, IECEx KEMA, Kosha, FM, CSA, INMETRO TÜV |
| Weights & Measures | NMi, PTB, BRML, UMI, LNE, DZM, ONML, W&M India, PAC, MIGAS, OIML, and several others |
| Other Approvals/Certificates | NEPSI, PESO (India), GOST-Rx |
| Ingress Protection | IP66/IP67 (NEMA 4X) |
| Weight | ≈16 kg (35 lb), depending on installed options and excluding antenna and tank separator |
| Dimensions | 217 x 319 x 379 mm (8.55 in x 12.55 in x 14.9 in) (H x W x L) |
| Cable Entries | 3 x 3/4 in NPT *6 or 6 x M20 |
| Update Time | 0.1 sec |
| Measuring Resolution | 0.1 mm (0.001 in) |
| Measuring Range | Up to 75 m (246 ft) |
| Instrument Accuracy Level | Advanced performance SmartRadar ±3 mm (±0.12 in); High performance SmartRadar ±1 mm (±0.04 in); Xtreme performance SmartRadar ±0.4 mm (±0.016 in) |
| Tank Separator | AISI 316 Stainless Steel (Material no.: 1.4401); O-Rings Material FPM |
| O-Ring Material | NBR 70 |
| Antenna Materials | Ball Valve (optional with horn antenna): Stainless Steel CF8M (mat no.: 1.4408); High Pressure Horn Antennas: SS AISI 316 (mat. no.:1.4401) and PTFE (in high pressure tank separator); Planar (PAT) Antennas: SS AISI 316 (mat. no.: 1.4401) and FEP |
| Signal Processing | Fully digital using Enhanced Performance Signal Processing (EPSP) |
| Operating Frequency | Xband (9.538 GHz to 10.561 GHz) R&TTE, FCC compliant |
| Measuring Principle | FMCW/Synthesized Reflectometer |
| SIL Certification | TÜV certified for SIL 2 and SIL 3 |
| Overfill Protection | DIBt WHG, Corcon BVBA |
| Process Temperature Range | -200 to +250 deg C (-328 to +482 deg F) |
| Process Pressure Range | Horn Antennas: up to 40 bar/4 MPa (580 psi); Planar (PAT) Antennas: up to 6 bar/0.6 MPa (87 psi) |
| Power Supply | Autoselect 65 Vac to 240 Vac (+10% to -15%) 50/60 Hz and/or 24 Vdc to 65 Vdc (+10% to -15%) |
| Power Rating | Typical 15 W; max. 23 W with all options |
| Maximum Current | Imax = 1.2 A (start-up) |
| Material Finish | Hard anodized according to MIL A8625-E Type III |
| Instrument Housing | Cast aluminum alloy according to EN1706, AA A356 EN1706, AC-AlSi7Mg0.3 |
| Cover | Aluminum; coating: Polyurethane |
| Inputs | VITO Temperature/Water Probe, Spot RTD (3 wire or 4 wire RTD, one or 2 element), (MPT/MRT up to 6 elements), HART® Inputs |
| Digital and Analog Combined | SIL AO + 1 SIL DO + 1 SIL DO contact; SIL AO + 2 SIL DO Contact |
| Digital Output Specification | 1x SIL DO contact (1x SPDT contact, 2A at 250 Vac or 2 A at 40 Vdc, Pmax= 500 W); 2x SIL DO contact (2x SPDT contact, 2A at 250 Vac or 2 A at 40 Vdc, Pmax= 500 W) |
| Analog Output Specification | SIL AO NAMUR NE43 compliant |
| Data Communication | Enraf Fieldbus (BPM), TRL/2, Modbus RTU, HART® Slave-Multidrop/or 4-20 mA, RS-232/RS-485 GPU Protocol, Wireless (ISA100/IEC62734) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
3 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 971 | SMART RADAR LTI | Request quotation |
| 990 | FLEXLINE RADAR | Request quotation |
| U1690043 | UPGRADE KIT CAN-SIL AO for 990 | Request quotation |
Manufacturer sources
https://process.honeywell.com/us/en/products/terminals/enraf-tank-gauging/enraf-flexline-radar-990
Last source check: 2026-11-02
Enraf Flexline Radar 990 Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.