Enraf Tank Gauging
Enraf Tank Temperature Measurement
Enraf temperature measurement ranges from single-point probes to multipoint VITO systems for bulk-liquid storage.
Enraf temperature measurement ranges from single-point probes to multipoint VITO systems for bulk-liquid storage. Compatible interfaces link temperature information with radar or servo gauges, and a water-level probe can be added where required. Combining these measurements supports tank inventory calculations while reducing separate wiring, with the arrangement selected around spot or average-temperature requirements.
Features & Benefits
- Portfolio
- Spot probes and VITO multipoint temperature systems
- Combines measurements to reduce wiring and installation work
Applications
- Bulk-liquid terminals and storage facilities
Detailed capabilities
Product and configuration
Enraf temperature measurement ranges from single-point probes to multipoint VITO systems for bulk-liquid storage. Compatible interfaces link temperature information with radar or servo gauges, and a water-level probe can be added where required. Combining these measurements supports tank inventory calculations while reducing separate wiring, with the arrangement selected around spot or average-temperature requirements.
- Portfolio: Spot probes and VITO multipoint temperature systems
Operation and integration
Spot probes connect directly to a level gauge. VITO MRT uses resistor elements of different lengths and selects the longest fully submerged element for an average reading. VITO LT uses nine elements for product and gas temperatures, while VITO MTT uses sixteen. A water-level probe can be integrated, and the VITO interface connects temperature data with compatible radar or servo measurement.
Application and selection
The top-end LT and MTT systems are described for custody-transfer use under the applicable weights-and-measures arrangements; MTT is also identified for LNG storage. Probe count, average-temperature method and water-level option must follow the tank contents and inventory purpose. A single spot probe is not equivalent to a multipoint temperature profile.
Environmental Safety
- Ambient Temperature Range
- -40 to +60 deg C (-40 to +140 deg F)
- Storage Temperature Range
- LT/ MTT Probe: -55 to +135 deg C (-67 to +275 deg F); MPT Probe: -50 to +120 deg C
- Safety Approvals
- LT/MTT Probe/ Interface Card: ATEX KEMA, IECEx, Kosha, FM, CSA , INMETRO TÜV; MPT Probe : EN IEC 60079-11, clause 5.7
- Operating Pressure
- LT/MTT Probe: 5 bar/500 kPa (72 psi) Hydrostatic pressure; MPT Probe: 6 bar/600 kPa (90 psi) hydrostatic pressure
Mechanical
- Sheath Material
- AISI 316L Stainless Steel
- Probe Outer Diameter
- With Water Sensing - 40 mm (1.57 in); Without Water Sensing - LT Probe 27 mm (1.06 in), MPT Probe 28.6 mm (1.2 in)
- Mounting Flange
- Optional, 1/2 BSP threaded mounting hole required
- Cable Entries
- M20 x 1.5, 3/4 in NPT via reducer and PG16 via reducer
- Anchor Weight
- Optional, max. 23 kg (50 lb)
Water Sensing-Optional
- Sensor Type
- PTFE sheathed capacitive probe
- Minimum Water Level
- 25 mm (0.98 in)
Measuring Specifications
- Probe Temperature Range
- LT/ MTT Probe: -55 to +135 deg C (-67 to +275 deg F); MPT Probe: -50 to +120 deg C
- Probe Accuracy
- 1/10 DIN Class B = ± (0.12+0.0015·; t; ) deg C; LT/ MTT Probe: ±0.1 deg C (±0.18 deg F); MPT Probe: 1/6 DIN Class B = ± (0.15+0.002·
- Measuring Resolution
- 0.01 deg C
- Measuring Range
- ±2 mm (0.078 in)
Principle
- Number of Elements
- LT Probe: 9 elements; MTT Probe: 16 elements
VITO Interface
- Mounting
- Direct on VITO probes using standard 1/2 in BSP entry
- Housing
- Chromatized, Polyurethane coated Aluminum, GD-AISi10Mg
- Data Communication
- HART® Communication to Tank Gauging ATG
- Application
- An electronic converter used in combination with the VITO probes
General
- Measuring Principle
- Cold junction compensated thermocouples (type T) to measure the temperature differentials with respect to a 4 wire 1/5 DIN Class A Pt100 reference resistor, physically embedded to cold junction
Explosion Safety & Legal Metrology Approvals
- Ingress Protection
- IP66/IP67
| Parameter | Published value / configuration |
|---|---|
| Ambient Temperature Range | -40 to +60 deg C (-40 to +140 deg F) |
| Storage Temperature Range | LT/ MTT Probe: -55 to +135 deg C (-67 to +275 deg F); MPT Probe: -50 to +120 deg C |
| Safety Approvals | LT/MTT Probe/ Interface Card: ATEX KEMA, IECEx, Kosha, FM, CSA , INMETRO TÜV; MPT Probe : EN IEC 60079-11, clause 5.7 |
| Operating Pressure | LT/MTT Probe: 5 bar/500 kPa (72 psi) Hydrostatic pressure; MPT Probe: 6 bar/600 kPa (90 psi) hydrostatic pressure |
| Sheath Material | AISI 316L Stainless Steel |
| Probe Outer Diameter | With Water Sensing - 40 mm (1.57 in); Without Water Sensing - LT Probe 27 mm (1.06 in), MPT Probe 28.6 mm (1.2 in) |
| Mounting Flange | Optional, 1/2 BSP threaded mounting hole required |
| Cable Entries | M20 x 1.5, 3/4 in NPT via reducer and PG16 via reducer |
| Anchor Weight | Optional, max. 23 kg (50 lb) |
| Sensor Type | PTFE sheathed capacitive probe |
| Minimum Water Level | 25 mm (0.98 in) |
| Probe Temperature Range | LT/ MTT Probe: -55 to +135 deg C (-67 to +275 deg F); MPT Probe: -50 to +120 deg C |
| Probe Accuracy | 1/10 DIN Class B = ± (0.12+0.0015·; t; ) deg C; LT/ MTT Probe: ±0.1 deg C (±0.18 deg F); MPT Probe: 1/6 DIN Class B = ± (0.15+0.002· |
| Measuring Resolution | 0.01 deg C |
| Measuring Range | ±2 mm (0.078 in) |
| Number of Elements | LT Probe: 9 elements; MTT Probe: 16 elements |
| Mounting | Direct on VITO probes using standard 1/2 in BSP entry |
| Housing | Chromatized, Polyurethane coated Aluminum, GD-AISi10Mg |
| Data Communication | HART® Communication to Tank Gauging ATG |
| Application | An electronic converter used in combination with the VITO probes |
| Measuring Principle | Cold junction compensated thermocouples (type T) to measure the temperature differentials with respect to a 4 wire 1/5 DIN Class A Pt100 reference resistor, physically embedded to cold junction |
| Ingress Protection | IP66/IP67 |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Resources
Resources linked from the manufacturer’s page. Confirm the document revision and applicable model before installation or ordering.
Honeywell resource listing ↗Part Number
Published part numbers
4 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 305 | SPOT THERMOMETER | Request quotation |
| 365 | MPT Probe+Water | Request quotation |
| 765 | VITO WATER PROBE | Request quotation |
| U0762560 | VITO IP Adapter Kit | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Vito Interface Image · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.