Honeywell Process Measurement & Control

Self-Recuperative and Radiant Tube Burners

UNI-RAD®

UNI-RAD uses annular electrodes and high-energy plasma-style ignition for stable radiant-tube firing.

UNI-RAD uses annular electrodes and high-energy plasma-style ignition for stable radiant-tube firing. Adjusting combustion-to-ignition air changes flame length, supporting tube temperature uniformity. Preheated-air options, pulse operation, suitable flame scanners and enhanced cooling arrangements are described with application qualifications, including the need for the correct valves and customer-supplied tube system.

Features & Benefits

Typical Radiant Tube Length
> 4 m
Stack Temperature
640 to 750 deg C (1184 to 1382 deg F) at 3% O₂
Recuperator Compatibility
Radiant tube ID ≥ 186 mm (7 in), length > 4 m (15.7 in), leg spacing > 600 mm (23.6 in)
NOx Emissions
140 to 250 mg/m³ at 3% O₂ (optimized via FGR)
Maintenance Interval
Twice per year (more frequent if media is contaminated)
Installation Notes
Gas nozzle must be flush with burner tip inner face
Ignition Type
Plasma type high energy ignition (no spark plug)
Hydrogen Capability
100% H₂ capable
Fuel Type
Natural Gas (NG), Liquefied Petroleum Gas (LPG), Coke Oven Gas (COG), LNG, Hydrogen (up to 100%)
Flame Type
Long, luminous diffusion flame
Flame Supervision
UV or IR Scanners
Efficiency
64% to 70% (Hi) (Burner + Recuperator)
Control Type
On/Off (modulation possible within limits)
Combustion Air Requirements
Dry, clean, no condensate
Combustion Air Preheat Temperature
500 to 600 deg C (932 to 1112 deg F)
Capacity Range
100 to 200 kW (Lower Heating Value - LHV)
Burner Type
Nozzle‑mix burner
Approvals
Compliant with Eurasian Customs Union standards
  • Continuous plasma-style ignition permits rapid pulse firing.
  • Adjustable flame length supports even tube heating.

Applications

  • Radiant-tube furnace heating
  • Rapid cooling with the described secondary manifold arrangement

Detailed capabilities

Continuous high-energy ignition and flame shaping

UNI-RAD uses the primary air and gas inlet tubes as annular ignition electrodes, creating a larger ignition area than a conventional spark plug. A small fuel-enriched zone of ionized air supplies the high-energy ignition source. Altering the balance between combustion and ignition air changes flame length so heat can be distributed along the tube over the published input range, including preheated-air configurations.

Manufacturer reference ↗

Pulse firing, supervision and cooling options

The continuously available spark supports pulse firing from the described duration-adjusting PID output. The source also notes intermittent-spark trials, so continuous spark is not stated as mandatory in every installation. Tight tube-temperature control requires appropriate valves. UV/IR supervision and secondary cooling manifolds are application options requiring consultation. The named customer-supplied tube types include pressure, negative-pressure and electrified arrangements; those choices do not establish one universal pressure rating.

Manufacturer reference ↗

Features and benefits

  • Continuous plasma-style ignition permits rapid pulse firing.
  • Adjustable flame length supports even tube heating.

Manufacturer reference ↗

Published application context

  • Radiant-tube furnace heating
  • Rapid cooling with the described secondary manifold arrangement

Manufacturer reference ↗

Specifications

Applications & Compatibility

Applications
Heat treatment lines in metals industry (W-shaped and U-shaped tubes)

Burner/Flame‑Related Lengths

Typical Radiant Tube Length
> 4 m

Air/Exhaust/Flue Gas Temperatures

Stack Temperature
640 to 750 deg C (1184 to 1382 deg F) at 3% O₂

System/Upgrade Compatibility

Recuperator Compatibility
Radiant tube ID ≥ 186 mm (7 in), length > 4 m (15.7 in), leg spacing > 600 mm (23.6 in)

Processing & Performance Metrics

NOx Emissions
140 to 250 mg/m³ at 3% O₂ (optimized via FGR)
Efficiency
64% to 70% (Hi) (Burner + Recuperator)
Capacity Range
100 to 200 kW (Lower Heating Value - LHV)

Electrical Specifications

Maintenance Interval
Twice per year (more frequent if media is contaminated)

Installation & Mounting Specifications

Installation Notes
Gas nozzle must be flush with burner tip inner face

Ignition, Flame & Supervision Specifications

Ignition Type
Plasma type high energy ignition (no spark plug)
Flame Type
Long, luminous diffusion flame
Flame Supervision
UV or IR Scanners

Fuel, Gas & Media Specifications

Hydrogen Capability
100% H₂ capable
Fuel Type
Natural Gas (NG), Liquefied Petroleum Gas (LPG), Coke Oven Gas (COG), LNG, Hydrogen (up to 100%)

Control, Logic & Functional Behavior

Control Type
On/Off (modulation possible within limits)

Air & Combustion Air Specifications

Combustion Air Requirements
Dry, clean, no condensate

Combustion/Furnace/Chamber Temperatures

Combustion Air Preheat Temperature
500 to 600 deg C (932 to 1112 deg F)

Overview

Burner Type
Nozzle‑mix burner

Standards & Certifications

Approvals
Compliant with Eurasian Customs Union standards
UNI-RAD® — manufacturer page values
ParameterPublished value / configuration
ApplicationsHeat treatment lines in metals industry (W-shaped and U-shaped tubes)
Typical Radiant Tube Length> 4 m
Stack Temperature640 to 750 deg C (1184 to 1382 deg F) at 3% O₂
Recuperator CompatibilityRadiant tube ID ≥ 186 mm (7 in), length > 4 m (15.7 in), leg spacing > 600 mm (23.6 in)
NOx Emissions140 to 250 mg/m³ at 3% O₂ (optimized via FGR)
Efficiency64% to 70% (Hi) (Burner + Recuperator)
Capacity Range100 to 200 kW (Lower Heating Value - LHV)
Maintenance IntervalTwice per year (more frequent if media is contaminated)
Installation NotesGas nozzle must be flush with burner tip inner face
Ignition TypePlasma type high energy ignition (no spark plug)
Flame TypeLong, luminous diffusion flame
Flame SupervisionUV or IR Scanners
Hydrogen Capability100% H₂ capable
Fuel TypeNatural Gas (NG), Liquefied Petroleum Gas (LPG), Coke Oven Gas (COG), LNG, Hydrogen (up to 100%)
Control TypeOn/Off (modulation possible within limits)
Combustion Air RequirementsDry, clean, no condensate
Combustion Air Preheat Temperature500 to 600 deg C (932 to 1112 deg F)
Burner TypeNozzle‑mix burner
ApprovalsCompliant with Eurasian Customs Union standards

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
1049543MOD 5"-1.5" BRNR AIR INLT HSGRequest quotation
1050671.625" ID CRMC INSLRequest quotation
10523923.75"-4.875" RECUP TBNG L=19"Request quotation
105313815.5" AIR INLT TB ASYRequest quotation
10531731.25"-4.25"C BRNR AIR INLT HSGRequest quotation
10531741.5"-6"C BRNR AIR INLT HSGRequest quotation
1053208MOD 4" RECUPRequest quotation
10532327.625" OD UNI-RAD RINGRequest quotation
10532368.875" OD UNI-RAD RINGRequest quotation
1056165IGN RODRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/self-recuperative-and-radiant-tube-burners/uni-rad

Last source check: 2026-11-02

UNI-RAD Product Image · Manufacturer ownership retained; republication licence not independently confirmed

UNI-RAD Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.