Self-Recuperative and Radiant Tube Burners
UNI-RAD®
UNI-RAD uses annular electrodes and high-energy plasma-style ignition for stable radiant-tube firing.
UNI-RAD uses annular electrodes and high-energy plasma-style ignition for stable radiant-tube firing. Adjusting combustion-to-ignition air changes flame length, supporting tube temperature uniformity. Preheated-air options, pulse operation, suitable flame scanners and enhanced cooling arrangements are described with application qualifications, including the need for the correct valves and customer-supplied tube system.
Features & Benefits
- Typical Radiant Tube Length
- > 4 m
- Stack Temperature
- 640 to 750 deg C (1184 to 1382 deg F) at 3% O₂
- Recuperator Compatibility
- Radiant tube ID ≥ 186 mm (7 in), length > 4 m (15.7 in), leg spacing > 600 mm (23.6 in)
- NOx Emissions
- 140 to 250 mg/m³ at 3% O₂ (optimized via FGR)
- Maintenance Interval
- Twice per year (more frequent if media is contaminated)
- Installation Notes
- Gas nozzle must be flush with burner tip inner face
- Ignition Type
- Plasma type high energy ignition (no spark plug)
- Hydrogen Capability
- 100% H₂ capable
- Fuel Type
- Natural Gas (NG), Liquefied Petroleum Gas (LPG), Coke Oven Gas (COG), LNG, Hydrogen (up to 100%)
- Flame Type
- Long, luminous diffusion flame
- Flame Supervision
- UV or IR Scanners
- Efficiency
- 64% to 70% (Hi) (Burner + Recuperator)
- Control Type
- On/Off (modulation possible within limits)
- Combustion Air Requirements
- Dry, clean, no condensate
- Combustion Air Preheat Temperature
- 500 to 600 deg C (932 to 1112 deg F)
- Capacity Range
- 100 to 200 kW (Lower Heating Value - LHV)
- Burner Type
- Nozzle‑mix burner
- Approvals
- Compliant with Eurasian Customs Union standards
- Continuous plasma-style ignition permits rapid pulse firing.
- Adjustable flame length supports even tube heating.
Applications
- Radiant-tube furnace heating
- Rapid cooling with the described secondary manifold arrangement
Detailed capabilities
Continuous high-energy ignition and flame shaping
UNI-RAD uses the primary air and gas inlet tubes as annular ignition electrodes, creating a larger ignition area than a conventional spark plug. A small fuel-enriched zone of ionized air supplies the high-energy ignition source. Altering the balance between combustion and ignition air changes flame length so heat can be distributed along the tube over the published input range, including preheated-air configurations.
Pulse firing, supervision and cooling options
The continuously available spark supports pulse firing from the described duration-adjusting PID output. The source also notes intermittent-spark trials, so continuous spark is not stated as mandatory in every installation. Tight tube-temperature control requires appropriate valves. UV/IR supervision and secondary cooling manifolds are application options requiring consultation. The named customer-supplied tube types include pressure, negative-pressure and electrified arrangements; those choices do not establish one universal pressure rating.
Features and benefits
- Continuous plasma-style ignition permits rapid pulse firing.
- Adjustable flame length supports even tube heating.
Published application context
- Radiant-tube furnace heating
- Rapid cooling with the described secondary manifold arrangement
Applications & Compatibility
- Applications
- Heat treatment lines in metals industry (W-shaped and U-shaped tubes)
Burner/Flame‑Related Lengths
- Typical Radiant Tube Length
- > 4 m
Air/Exhaust/Flue Gas Temperatures
- Stack Temperature
- 640 to 750 deg C (1184 to 1382 deg F) at 3% O₂
System/Upgrade Compatibility
- Recuperator Compatibility
- Radiant tube ID ≥ 186 mm (7 in), length > 4 m (15.7 in), leg spacing > 600 mm (23.6 in)
Processing & Performance Metrics
- NOx Emissions
- 140 to 250 mg/m³ at 3% O₂ (optimized via FGR)
- Efficiency
- 64% to 70% (Hi) (Burner + Recuperator)
- Capacity Range
- 100 to 200 kW (Lower Heating Value - LHV)
Electrical Specifications
- Maintenance Interval
- Twice per year (more frequent if media is contaminated)
Installation & Mounting Specifications
- Installation Notes
- Gas nozzle must be flush with burner tip inner face
Ignition, Flame & Supervision Specifications
- Ignition Type
- Plasma type high energy ignition (no spark plug)
- Flame Type
- Long, luminous diffusion flame
- Flame Supervision
- UV or IR Scanners
Fuel, Gas & Media Specifications
- Hydrogen Capability
- 100% H₂ capable
- Fuel Type
- Natural Gas (NG), Liquefied Petroleum Gas (LPG), Coke Oven Gas (COG), LNG, Hydrogen (up to 100%)
Control, Logic & Functional Behavior
- Control Type
- On/Off (modulation possible within limits)
Air & Combustion Air Specifications
- Combustion Air Requirements
- Dry, clean, no condensate
Combustion/Furnace/Chamber Temperatures
- Combustion Air Preheat Temperature
- 500 to 600 deg C (932 to 1112 deg F)
Overview
- Burner Type
- Nozzle‑mix burner
Standards & Certifications
- Approvals
- Compliant with Eurasian Customs Union standards
| Parameter | Published value / configuration |
|---|---|
| Applications | Heat treatment lines in metals industry (W-shaped and U-shaped tubes) |
| Typical Radiant Tube Length | > 4 m |
| Stack Temperature | 640 to 750 deg C (1184 to 1382 deg F) at 3% O₂ |
| Recuperator Compatibility | Radiant tube ID ≥ 186 mm (7 in), length > 4 m (15.7 in), leg spacing > 600 mm (23.6 in) |
| NOx Emissions | 140 to 250 mg/m³ at 3% O₂ (optimized via FGR) |
| Efficiency | 64% to 70% (Hi) (Burner + Recuperator) |
| Capacity Range | 100 to 200 kW (Lower Heating Value - LHV) |
| Maintenance Interval | Twice per year (more frequent if media is contaminated) |
| Installation Notes | Gas nozzle must be flush with burner tip inner face |
| Ignition Type | Plasma type high energy ignition (no spark plug) |
| Flame Type | Long, luminous diffusion flame |
| Flame Supervision | UV or IR Scanners |
| Hydrogen Capability | 100% H₂ capable |
| Fuel Type | Natural Gas (NG), Liquefied Petroleum Gas (LPG), Coke Oven Gas (COG), LNG, Hydrogen (up to 100%) |
| Control Type | On/Off (modulation possible within limits) |
| Combustion Air Requirements | Dry, clean, no condensate |
| Combustion Air Preheat Temperature | 500 to 600 deg C (932 to 1112 deg F) |
| Burner Type | Nozzle‑mix burner |
| Approvals | Compliant with Eurasian Customs Union standards |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 1049543 | MOD 5"-1.5" BRNR AIR INLT HSG | Request quotation |
| 1050671 | .625" ID CRMC INSL | Request quotation |
| 1052392 | 3.75"-4.875" RECUP TBNG L=19" | Request quotation |
| 1053138 | 15.5" AIR INLT TB ASY | Request quotation |
| 1053173 | 1.25"-4.25"C BRNR AIR INLT HSG | Request quotation |
| 1053174 | 1.5"-6"C BRNR AIR INLT HSG | Request quotation |
| 1053208 | MOD 4" RECUP | Request quotation |
| 1053232 | 7.625" OD UNI-RAD RING | Request quotation |
| 1053236 | 8.875" OD UNI-RAD RING | Request quotation |
| 1056165 | IGN ROD | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
UNI-RAD Product Image · Manufacturer ownership retained; republication licence not independently confirmed
UNI-RAD Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.