Self-Recuperative and Radiant Tube Burners
ECOMAX
ECOMAX integrates a recuperator with the burner for direct or indirect furnace heating.
ECOMAX integrates a recuperator with the burner for direct or indirect furnace heating. Ceramic, ribbed cast-steel and flat-tube versions serve different configurations. Seven sizes cover 25–500 kW with on/off control, direct ignition and supervision; the source lists natural gas, town gas, LPG and low-calorific gas options.
Features & Benefits
- Adjusting Range
- 60 to 100%
- VAH Connection Set
- Gas control line connection
- UV Adapter Set
- For UV sensor installation
- Purge Air/Cooling Air Nozzles
- Prevent condensation and overheating
- Operating Modes
- ON/OFF, intermittent operation
- Number of Sizes
- 7 sizes (ECOMAX 0 to ECOMAX 6)
- Maximum Flue Gas Temperature
- C Recuperator - 1250 deg C (2282 deg F)|F Recuperator - 1050 deg C (1922 deg F)|M/P Recuperator - 1150 deg C (2102 deg F)
- Maximum Air Preheat Temperature
- Up to approximately 650 deg C
- Material
- Cast Aluminium, Double‑Wall Design
- Maintenance Interval
- Twice per year (more frequent if media is contaminated)
- Installation Orientation
- Horizontal, vertical, or angled (within limits)
- Ignition Type
- Direct Spark Ignition
- Heating Type
- Direct heating and radiant tube heating
- Gas Type
- Natural Gas, LPG, Coke Oven Gas, Low Calorific Value Gas
- Flame Velocity
- Approximately 130-170 m/s
- Flame Control
- Ionization (UV optional)
- Control Type
- On/Off
- Combustion Principle
- Two‑stage combustion with internal flue gas heat recovery
- Capacity Range
- 25 to 500 kW (LHV)
- Burner Versions
- ECOMAX..C, ECOMAX..M, ECOMAX..P, ECOMAX..F
- Burner Type
- Self‑recuperative gas burner
- Approvals
- Machinery Directive 2006/42/EC, Eurasian Customs Union
- Integrated exhaust recovery preheats the combustion air.
Applications
- Direct and indirect furnace heating
Processing & Performance Metrics
- Adjusting Range
- 60 to 100%
- Capacity Range
- 25 to 500 kW (LHV)
Connections & Interfaces
- VAH Connection Set
- Gas control line connection
Ignition, Flame & Supervision Specifications
- UV Adapter Set
- For UV sensor installation
- Ignition Type
- Direct Spark Ignition
- Flame Velocity
- Approximately 130-170 m/s
- Flame Control
- Ionization (UV optional)
Air & Combustion Air Specifications
- Purge Air/Cooling Air Nozzles
- Prevent condensation and overheating
Control, Logic & System Behavior
- Operating Modes
- ON/OFF, intermittent operation
Dimensions & Size Specifications
- Number of Sizes
- 7 sizes (ECOMAX 0 to ECOMAX 6)
Air/Exhaust/Flue Gas Temperatures
- Maximum Flue Gas Temperature
- C Recuperator - 1250 deg C (2282 deg F); F Recuperator - 1050 deg C (1922 deg F); M/P Recuperator - 1150 deg C (2102 deg F)
- Maximum Air Preheat Temperature
- Up to approximately 650 deg C
Material Specifications
- Material
- Cast Aluminium, Double‑Wall Design
Electrical Specifications
- Maintenance Interval
- Twice per year (more frequent if media is contaminated)
Installation & Mounting Specifications
- Installation Orientation
- Horizontal, vertical, or angled (within limits)
Thermal, Flow & Process Characteristics
- Heating Type
- Direct heating and radiant tube heating
Fuel, Gas & Media Specifications
- Gas Type
- Natural Gas, LPG, Coke Oven Gas, Low Calorific Value Gas
Control, Logic & Functional Behavior
- Control Type
- On/Off
Combustion, Mixing & Fuel Dynamics
- Combustion Principle
- Two‑stage combustion with internal flue gas heat recovery
Product Design & Configuration
- Burner Versions
- ECOMAX..C, ECOMAX..M, ECOMAX..P, ECOMAX..F
Overview
- Burner Type
- Self‑recuperative gas burner
Standards & Certifications
- Approvals
- Machinery Directive 2006/42/EC, Eurasian Customs Union
Applications & Compatibility
- Applications
- Direct and radiant tube heating
| Parameter | Published value / configuration |
|---|---|
| Adjusting Range | 60 to 100% |
| Capacity Range | 25 to 500 kW (LHV) |
| VAH Connection Set | Gas control line connection |
| UV Adapter Set | For UV sensor installation |
| Ignition Type | Direct Spark Ignition |
| Flame Velocity | Approximately 130-170 m/s |
| Flame Control | Ionization (UV optional) |
| Purge Air/Cooling Air Nozzles | Prevent condensation and overheating |
| Operating Modes | ON/OFF, intermittent operation |
| Number of Sizes | 7 sizes (ECOMAX 0 to ECOMAX 6) |
| Maximum Flue Gas Temperature | C Recuperator - 1250 deg C (2282 deg F); F Recuperator - 1050 deg C (1922 deg F); M/P Recuperator - 1150 deg C (2102 deg F) |
| Maximum Air Preheat Temperature | Up to approximately 650 deg C |
| Material | Cast Aluminium, Double‑Wall Design |
| Maintenance Interval | Twice per year (more frequent if media is contaminated) |
| Installation Orientation | Horizontal, vertical, or angled (within limits) |
| Heating Type | Direct heating and radiant tube heating |
| Gas Type | Natural Gas, LPG, Coke Oven Gas, Low Calorific Value Gas |
| Control Type | On/Off |
| Combustion Principle | Two‑stage combustion with internal flue gas heat recovery |
| Burner Versions | ECOMAX..C, ECOMAX..M, ECOMAX..P, ECOMAX..F |
| Burner Type | Self‑recuperative gas burner |
| Approvals | Machinery Directive 2006/42/EC, Eurasian Customs Union |
| Applications | Direct and radiant tube heating |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 101034688 | BRNR,ECOMAX 5C545 SB/D DA3UA S31 B LBE21 | Request quotation |
| HK107707 | COMB CHMBR,ECOMAX 3M LBE 107707 | Request quotation |
| HK403794 | GSKT,ECOMAX 5,FLUE GAS GD TB KAOWOOL,1/8 | Request quotation |
| HK404396 | GSKT,ECOMAX 3M,FLUE GAS GD TB KAOWOOL,1/ | Request quotation |
| KS03109712 | O-Ring, 48.0 x 2.0, FKM 70 Shore Green | Request quotation |
| KS21106082 | FGTA-Set ECO 2C545-Z | Request quotation |
| KS21800135 | Gehaeuse-Einheit Eco 1C / 2C-W | Request quotation |
| KS21800155 | Intermediate flange AGT Eco 3C+ | Request quotation |
| KS21800499 | FGT-SET ECO 5M545-D | Request quotation |
| KS21800509 | SET GUANRIZIONI ECO 5C | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Self recuperative burner · Manufacturer ownership retained; republication licence not independently confirmed
Secondary Image for FGT Set, COMAX Self-recuperative burners · Manufacturer ownership retained; republication licence not independently confirmed
Secondary Image for EJEK, ECOMAX Self-recuperative burners · Manufacturer ownership retained; republication licence not independently confirmed
ECOMAX Self-recuperative burners · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.