Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Self-Recuperative and Radiant Tube Burners

ECOMAX

ECOMAX integrates a recuperator with the burner for direct or indirect furnace heating.

ECOMAX integrates a recuperator with the burner for direct or indirect furnace heating. Ceramic, ribbed cast-steel and flat-tube versions serve different configurations. Seven sizes cover 25–500 kW with on/off control, direct ignition and supervision; the source lists natural gas, town gas, LPG and low-calorific gas options.

Features & Benefits

Adjusting Range
60 to 100%
VAH Connection Set
Gas control line connection
UV Adapter Set
For UV sensor installation
Purge Air/Cooling Air Nozzles
Prevent condensation and overheating
Operating Modes
ON/OFF, intermittent operation
Number of Sizes
7 sizes (ECOMAX 0 to ECOMAX 6)
Maximum Flue Gas Temperature
C Recuperator - 1250 deg C (2282 deg F)|F Recuperator - 1050 deg C (1922 deg F)|M/P Recuperator - 1150 deg C (2102 deg F)
Maximum Air Preheat Temperature
Up to approximately 650 deg C
Material
Cast Aluminium, Double‑Wall Design
Maintenance Interval
Twice per year (more frequent if media is contaminated)
Installation Orientation
Horizontal, vertical, or angled (within limits)
Ignition Type
Direct Spark Ignition
Heating Type
Direct heating and radiant tube heating
Gas Type
Natural Gas, LPG, Coke Oven Gas, Low Calorific Value Gas
Flame Velocity
Approximately 130-170 m/s
Flame Control
Ionization (UV optional)
Control Type
On/Off
Combustion Principle
Two‑stage combustion with internal flue gas heat recovery
Capacity Range
25 to 500 kW (LHV)
Burner Versions
ECOMAX..C, ECOMAX..M, ECOMAX..P, ECOMAX..F
Burner Type
Self‑recuperative gas burner
Approvals
Machinery Directive 2006/42/EC, Eurasian Customs Union
  • Integrated exhaust recovery preheats the combustion air.

Applications

  • Direct and indirect furnace heating

Specifications

Processing & Performance Metrics

Adjusting Range
60 to 100%
Capacity Range
25 to 500 kW (LHV)

Connections & Interfaces

VAH Connection Set
Gas control line connection

Ignition, Flame & Supervision Specifications

UV Adapter Set
For UV sensor installation
Ignition Type
Direct Spark Ignition
Flame Velocity
Approximately 130-170 m/s
Flame Control
Ionization (UV optional)

Air & Combustion Air Specifications

Purge Air/Cooling Air Nozzles
Prevent condensation and overheating

Control, Logic & System Behavior

Operating Modes
ON/OFF, intermittent operation

Dimensions & Size Specifications

Number of Sizes
7 sizes (ECOMAX 0 to ECOMAX 6)

Air/Exhaust/Flue Gas Temperatures

Maximum Flue Gas Temperature
C Recuperator - 1250 deg C (2282 deg F); F Recuperator - 1050 deg C (1922 deg F); M/P Recuperator - 1150 deg C (2102 deg F)
Maximum Air Preheat Temperature
Up to approximately 650 deg C

Material Specifications

Material
Cast Aluminium, Double‑Wall Design

Electrical Specifications

Maintenance Interval
Twice per year (more frequent if media is contaminated)

Installation & Mounting Specifications

Installation Orientation
Horizontal, vertical, or angled (within limits)

Thermal, Flow & Process Characteristics

Heating Type
Direct heating and radiant tube heating

Fuel, Gas & Media Specifications

Gas Type
Natural Gas, LPG, Coke Oven Gas, Low Calorific Value Gas

Control, Logic & Functional Behavior

Control Type
On/Off

Combustion, Mixing & Fuel Dynamics

Combustion Principle
Two‑stage combustion with internal flue gas heat recovery

Product Design & Configuration

Burner Versions
ECOMAX..C, ECOMAX..M, ECOMAX..P, ECOMAX..F

Overview

Burner Type
Self‑recuperative gas burner

Standards & Certifications

Approvals
Machinery Directive 2006/42/EC, Eurasian Customs Union

Applications & Compatibility

Applications
Direct and radiant tube heating
ECOMAX — manufacturer page values
ParameterPublished value / configuration
Adjusting Range60 to 100%
Capacity Range25 to 500 kW (LHV)
VAH Connection SetGas control line connection
UV Adapter SetFor UV sensor installation
Ignition TypeDirect Spark Ignition
Flame VelocityApproximately 130-170 m/s
Flame ControlIonization (UV optional)
Purge Air/Cooling Air NozzlesPrevent condensation and overheating
Operating ModesON/OFF, intermittent operation
Number of Sizes7 sizes (ECOMAX 0 to ECOMAX 6)
Maximum Flue Gas TemperatureC Recuperator - 1250 deg C (2282 deg F); F Recuperator - 1050 deg C (1922 deg F); M/P Recuperator - 1150 deg C (2102 deg F)
Maximum Air Preheat TemperatureUp to approximately 650 deg C
MaterialCast Aluminium, Double‑Wall Design
Maintenance IntervalTwice per year (more frequent if media is contaminated)
Installation OrientationHorizontal, vertical, or angled (within limits)
Heating TypeDirect heating and radiant tube heating
Gas TypeNatural Gas, LPG, Coke Oven Gas, Low Calorific Value Gas
Control TypeOn/Off
Combustion PrincipleTwo‑stage combustion with internal flue gas heat recovery
Burner VersionsECOMAX..C, ECOMAX..M, ECOMAX..P, ECOMAX..F
Burner TypeSelf‑recuperative gas burner
ApprovalsMachinery Directive 2006/42/EC, Eurasian Customs Union
ApplicationsDirect and radiant tube heating

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
101034688BRNR,ECOMAX 5C545 SB/D DA3UA S31 B LBE21Request quotation
HK107707COMB CHMBR,ECOMAX 3M LBE 107707Request quotation
HK403794GSKT,ECOMAX 5,FLUE GAS GD TB KAOWOOL,1/8Request quotation
HK404396GSKT,ECOMAX 3M,FLUE GAS GD TB KAOWOOL,1/Request quotation
KS03109712O-Ring, 48.0 x 2.0, FKM 70 Shore GreenRequest quotation
KS21106082FGTA-Set ECO 2C545-ZRequest quotation
KS21800135Gehaeuse-Einheit Eco 1C / 2C-WRequest quotation
KS21800155Intermediate flange AGT Eco 3C+Request quotation
KS21800499FGT-SET ECO 5M545-DRequest quotation
KS21800509SET GUANRIZIONI ECO 5CRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/self-recuperative-and-radiant-tube-burners/ecomax

Last source check: 2026-11-02

Self recuperative burner · Manufacturer ownership retained; republication licence not independently confirmed

Secondary Image for FGT Set, COMAX Self-recuperative burners · Manufacturer ownership retained; republication licence not independently confirmed

Secondary Image for EJEK, ECOMAX Self-recuperative burners · Manufacturer ownership retained; republication licence not independently confirmed

ECOMAX Self-recuperative burners · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry