Bayonet-Ultra recuperators fit the exhaust leg of several radiant-tube geometries, recovering heat through multiple internal tubes.

Bayonet-Ultra recuperators fit the exhaust leg of several radiant-tube geometries, recovering heat through multiple internal tubes. Four sizes cover the stated tube diameters, with adjustable lengths and pressure-drop choices for retrofit matching. Installation can address one furnace tube at a time, while the air-cooled housing reduces local heat.

Features & Benefits

Sizes
3 BU, 4 BU, 5 BU, 6 BU
Compatible Radiant Tube Types
“U”, “O”, and Trident type radiant tubes
Maximum Exhaust Temperature
Up to 2100 deg F (clean exhaust)
Preheated Air Temperature
Up to ~740 deg F (393 deg C) depending on size and conditions
Air Outlet Connection
Square air outlet
Air Inlet Connection
2 in NPSC
Exhaust Stream Type
Clean exhaust streams
Alternative Version
Single-tube version for higher temps, dirty flue, or low pressure drop
Recuperator Design
Bayonet‑type
Material
Cold drawn NiCr stainless steel tubes, stainless steel exhaust extension
  • Multiple transfer tubes increase heat-recovery surface.
  • Installation can be performed on one tube without stopping the whole furnace.

Applications

  • Heat recovery in single, U, O, W and Trident radiant tubes

Detailed capabilities

Retrofit fit and pressure-drop matching

Bayonet-Ultra expands heat-recovery surface through several transfer tubes in the exhaust leg. Four sizes cover the stated radiant-tube bores, with length adjustment and pressure-drop choices to match an existing blower. New or retrofit work often avoids brick or tube alteration. On a multi-tube furnace, the described installation can isolate only the affected tube instead of stopping the complete furnace.

Manufacturer reference ↗

Features and benefits

  • Multiple transfer tubes increase heat-recovery surface.
  • Installation can be performed on one tube without stopping the whole furnace.

Manufacturer reference ↗

Published application context

  • Heat recovery in single, U, O, W and Trident radiant tubes

Manufacturer reference ↗

Specifications

Dimensions & Size Specifications

Sizes
3 BU, 4 BU, 5 BU, 6 BU

Component/Geometry Compatibility

Compatible Radiant Tube Types
“U”, “O”, and Trident type radiant tubes

Air/Exhaust/Flue Gas Temperatures

Maximum Exhaust Temperature
Up to 2100 deg F (clean exhaust)
Preheated Air Temperature
Up to ~740 deg F (393 deg C) depending on size and conditions

Connections & Interfaces

Air Outlet Connection
Square air outlet
Air Inlet Connection
2 in NPSC

Installation, Orientation & Layout

Exhaust Stream Type
Clean exhaust streams

Product Design & Configuration

Alternative Version
Single-tube version for higher temps, dirty flue, or low pressure drop

Combustion, Fuel & Mixing Sub‑Systems

Recuperator Design
Bayonet‑type

Applications & Compatibility

Applications
Radiant tube exhaust heat recovery

Material Specifications

Material
Cold drawn NiCr stainless steel tubes, stainless steel exhaust extension
Bayonet Ultra Recuperator — manufacturer page values
ParameterPublished value / configuration
Sizes3 BU, 4 BU, 5 BU, 6 BU
Compatible Radiant Tube Types“U”, “O”, and Trident type radiant tubes
Maximum Exhaust TemperatureUp to 2100 deg F (clean exhaust)
Preheated Air TemperatureUp to ~740 deg F (393 deg C) depending on size and conditions
Air Outlet ConnectionSquare air outlet
Air Inlet Connection2 in NPSC
Exhaust Stream TypeClean exhaust streams
Alternative VersionSingle-tube version for higher temps, dirty flue, or low pressure drop
Recuperator DesignBayonet‑type
ApplicationsRadiant tube exhaust heat recovery
MaterialCold drawn NiCr stainless steel tubes, stainless steel exhaust extension

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
101800-15RECUP,BAYONET ULTRA,4BU,15 IN LG,HP DROPRequest quotation
101800-16RECUP,BAYONET ULTRA,4BU,16 IN LG,HP DROPRequest quotation
101800-17RECUP,BAYONET ULTRA,4BU,17 IN LG,HP DROPRequest quotation
101800-18RECUP,BAYONET ULTRA,4BU,18 IN LG,HP DROPRequest quotation
101800-19RECUP,BAYONET ULTRA,4BU,19 IN LG,HP DROPRequest quotation
101800-20RECUP,BAYONET ULTRA,4BU,20 IN LG,HP DROPRequest quotation
101800-21RECUP,BAYONET ULTRA,4BU,21 IN LG,HP DROPRequest quotation
101800-22RECUP,BAYONET ULTRA,4BU,22 IN LG,HP DROPRequest quotation
101800-23RECUP,BAYONET ULTRA,4BU,23 IN LG,HP DROPRequest quotation
101800-24RECUP,BAYONET ULTRA,4BU,24 IN LG,HP DROPRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/self-recuperative-and-radiant-tube-burners/bayonet-ultra-recuperator

Last source check: 2026-11-02

Bayonet Ultra Recuperator · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry