Self-Recuperative and Radiant Tube Burners
Tube Firing Burner
TFB tube-firing burners use an adjustable spiraling flame to improve transfer and temperature distribution along radiant or immersion tubes.
TFB tube-firing burners use an adjustable spiraling flame to improve transfer and temperature distribution along radiant or immersion tubes. The page covers 300,000–2,000,000 Btu/hr, low excess-air operation and broad ignition range. Eclipse Bayonet-Ultra recuperators can be added for heat recovery in a compatible tube arrangement.
Features & Benefits
- Air Pressure Switch
- Required for safety; detects insufficient air pressure
- Safety Standards
- NFPA 86 Compliant
- Recuperator Type
- Exhaust leg recuperator
- Maximum Furnace Temperature
- Up to 1850 deg F (application dependent)
- Maximum Combustion Air Temperature
- Up to 1000 deg F
- Main Gas Shut-Off Valve Train
- Must comply with NFPA; minimum: two shut-off valves
- Ignition Type
- Direct Spark Ignition
- Heating Type
- Indirect heating
- Fuel Type
- Natural Gas, Propane, Butane
- Fuel Gross Heating Values
- Natural Gas: 1,002 BTU/ft³, Propane: 2,572 BTU/ft³, Butane: 3,225 BTU/ft³
- Flame Monitoring
- Flame rod (TFB030 and TFB075), UV scanner (all models)
- Efficiency
- As low as 39% depending on furnace temperature (without Recuperator)|Up to 71% depending on furnace temperature (with Recuperator)
- Control Method
- Modulating control, High/Low control
- Combustion Principle
- Direct tube firing with controlled air/fuel mixing
- Burner Type
- Nozzle-mixing burner for tube firing applications
- The spiraling flame increases tube transfer and temperature uniformity.
Applications
- Radiant- and immersion-tube firing
Detailed capabilities
A long adjustable spiral inside the tube
TFB's nozzle creates an adjustable-length spiral that sweeps the tube surface, reducing the insulating gas-film layer. The intended result is more even tube temperature and improved transfer, supporting consistent process heating and tube life. Low excess-air firing, low inlet-pressure requirements and a broad ignition range are described. Bayonet-Ultra recovery can be paired with a suitable tube system rather than assumed present on every burner.
Features and benefits
- The spiraling flame increases tube transfer and temperature uniformity.
Published application context
- Radiant- and immersion-tube firing
Air & Combustion Air Specifications
- Air Pressure Switch
- Required for safety; detects insufficient air pressure
Standards & Certifications
- Safety Standards
- NFPA 86 Compliant
Combustion, Fuel & Mixing Sub‑Systems
- Recuperator Type
- Exhaust leg recuperator
Overview
- Models
- TFB030, TFB075, TFB200
- Burner Type
- Nozzle-mixing burner for tube firing applications
Maximum/Minimum Temperature Limits
- Maximum Furnace Temperature
- Up to 1850 deg F (application dependent)
Combustion/Furnace/Chamber Temperatures
- Maximum Combustion Air Temperature
- Up to 1000 deg F
Actuation, Valve & Motion Control Specifications
- Main Gas Shut-Off Valve Train
- Must comply with NFPA; minimum: two shut-off valves
Ignition, Flame & Supervision Specifications
- Ignition Type
- Direct Spark Ignition
- Flame Monitoring
- Flame rod (TFB030 and TFB075), UV scanner (all models)
Thermal, Flow & Process Characteristics
- Heating Type
- Indirect heating
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas, Propane, Butane
Combustion, Mixing & Fuel Dynamics
- Fuel Gross Heating Values
- Natural Gas: 1,002 BTU/ft³, Propane: 2,572 BTU/ft³, Butane: 3,225 BTU/ft³
- Combustion Principle
- Direct tube firing with controlled air/fuel mixing
Processing & Performance Metrics
- Efficiency
- As low as 39% depending on furnace temperature (without Recuperator); Up to 71% depending on furnace temperature (with Recuperator)
Control, Logic & Functional Behavior
- Control Method
- Modulating control, High/Low control
Applications & Compatibility
- Applications
- Radiant tube heating, immersion tube heating
| Parameter | Published value / configuration |
|---|---|
| Air Pressure Switch | Required for safety; detects insufficient air pressure |
| Safety Standards | NFPA 86 Compliant |
| Recuperator Type | Exhaust leg recuperator |
| Models | TFB030, TFB075, TFB200 |
| Burner Type | Nozzle-mixing burner for tube firing applications |
| Maximum Furnace Temperature | Up to 1850 deg F (application dependent) |
| Maximum Combustion Air Temperature | Up to 1000 deg F |
| Main Gas Shut-Off Valve Train | Must comply with NFPA; minimum: two shut-off valves |
| Ignition Type | Direct Spark Ignition |
| Flame Monitoring | Flame rod (TFB030 and TFB075), UV scanner (all models) |
| Heating Type | Indirect heating |
| Fuel Type | Natural Gas, Propane, Butane |
| Fuel Gross Heating Values | Natural Gas: 1,002 BTU/ft³, Propane: 2,572 BTU/ft³, Butane: 3,225 BTU/ft³ |
| Combustion Principle | Direct tube firing with controlled air/fuel mixing |
| Efficiency | As low as 39% depending on furnace temperature (without Recuperator); Up to 71% depending on furnace temperature (with Recuperator) |
| Control Method | Modulating control, High/Low control |
| Applications | Radiant tube heating, immersion tube heating |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 10001260-1 | EXT,SI,SPRK,SELF GNDG,1300MM LG,125MM IS | Request quotation |
| 10034234 | PPST,0.5 IN.,NPT,STL SHL,ELECTROLYTICALL | Request quotation |
| 10053512-1 | KIT,LIT,TB FRNG BRNR,TFB030,ENG | Request quotation |
| 10053512-2 | KIT,LIT,TB FRNG BRNR,TFB075,ENG | Request quotation |
| 10053512-3 | KIT,LIT,TB FRNG BRNR,TFB200,ENG | Request quotation |
| 101017271 | CVR,REAR,TFB030,TFB075,BLK,HT | Request quotation |
| 101017345 | CVR,REAR,TFB200,BLK,HT | Request quotation |
| 1030RBK | 1030,1238 TOF REPLACEMENT BLOWER KIT | Request quotation |
| 13229 | GSKT,BKPLT,4.00 IN.,X 3.44 IN.,SQ,TFB 63 | Request quotation |
| 13230 | GSKT,FLG,SQ,6.00 X 4.75 IN.,TFB63 | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Tube Firing Burner Product Image · Manufacturer ownership retained; republication licence not independently confirmed
Tube Firing Burner Product Diagram 1 · Manufacturer ownership retained; republication licence not independently confirmed
Tube Firing Burner Product Diagram · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.
