Self-Recuperative and Radiant Tube Burners
Single Ended Radiant Tube Burner (SER)
SER V5 combines burner and recuperator concentrically within a radiant tube.
SER V5 combines burner and recuperator concentrically within a radiant tube. Counterflow exhaust recovery and a dual-finned combustor preheat combustion air, while insulation limits heat escaping near the mounting. Horizontal or vertical installation is described; fuel and NOx reductions are manufacturer comparisons against specified earlier burner arrangements.
Features & Benefits
- Specific Gravity
- 0.6
- Recuperator Type
- Internal recuperator
- Pipe Connection Type
- BSP and NPT thread standards
- Outer Tube
- Ceramic or Metallic
- Minimum Blower Pressure
- ≥ 15 in. w.c. (37 mbar) recommended
- Maximum Furnace Temperature
- 1850 deg F (1010 deg C)
- Main Gas Safety
- Dual shut‑off valves per NFPA
- Ignition Type
- Direct Spark Ignition
- Heating Value
- 1004 Btu/ft³ (40 MJ/m³)
- Heating Type
- Indirect heating
- Fuel Type
- Natural Gas (CH₄ ≥ 90%)
- Flame Sensor
- UV Scanner
- Flame Monitoring
- UV Scanner (required for ceramic tubes)
- Flame Length
- Based on tube length and model
- Exhaust Housing
- Insulated for cooler working environment
- Diameter
- 4.5 in, 6 in, 8 in
- Control Type
- High/Low pulse firing (modulating optional)
- Burner Type
- Nozzle-mix burner with integrated recuperator
- Burner Configuration
- Single‑ended
- Integrated recovery avoids external recuperators and insulated air piping.
- Insulated mounting components reduce heat near the working area.
Applications
- Single-ended radiant-tube furnace heating
Detailed capabilities
Counterflow recovery inside the radiant tube
SER V5 places burner and recuperator coaxially inside the tube. Exhaust heat travels back toward the incoming combustion air through a counterflow path, producing preheat without external recovery ductwork. A dual-finned combustor expands the transfer area. The insulated mounting flange and exhaust housing retain useful heat and lower the surrounding working temperature compared with an uninsulated heat-loss path.
Efficiency comparisons and mounting
Honeywell reports fuel savings against sealed ambient-air burners and still larger savings against atmospheric equipment, together with a NOx reduction relative to conventional recuperative burners. These are different comparison baselines and should not be merged into a universal savings percentage. The compact assembly supports vertical or horizontal installation in suitable furnaces, with heat-flux uniformity intended to support even processing and radiant-tube life.
Features and benefits
- Integrated recovery avoids external recuperators and insulated air piping.
- Insulated mounting components reduce heat near the working area.
Published application context
- Single-ended radiant-tube furnace heating
Applications & Compatibility
- Applications
- Radiant tube heating in industrial furnaces
Measurement, Media & Physical Properties
- Specific Gravity
- 0.6
Combustion, Fuel & Mixing Sub‑Systems
- Recuperator Type
- Internal recuperator
- Burner Configuration
- Single‑ended
Connections & Interfaces
- Pipe Connection Type
- BSP and NPT thread standards
Mechanical Design & Hardware Details
- Outer Tube
- Ceramic or Metallic
Overview
- Models
- SER450, SER600, SER800
- Burner Type
- Nozzle-mix burner with integrated recuperator
Pressure Specifications
- Minimum Blower Pressure
- ≥ 15 in. w.c. (37 mbar) recommended
Maximum/Minimum Temperature Limits
- Maximum Furnace Temperature
- 1850 deg F (1010 deg C)
Safety, Protection & Reliability
- Main Gas Safety
- Dual shut‑off valves per NFPA
Ignition, Flame & Supervision Specifications
- Ignition Type
- Direct Spark Ignition
- Flame Sensor
- UV Scanner
- Flame Monitoring
- UV Scanner (required for ceramic tubes)
Thermal, Flow & Process Characteristics
- Heating Value
- 1004 Btu/ft³ (40 MJ/m³)
- Heating Type
- Indirect heating
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas (CH₄ ≥ 90%)
Burner/Flame‑Related Lengths
- Flame Length
- Based on tube length and model
Mechanical Design & Adjustment Characteristics
- Exhaust Housing
- Insulated for cooler working environment
Dimensions & Size Specifications
- Diameter
- 4.5 in, 6 in, 8 in
Control, Logic & Functional Behavior
- Control Type
- High/Low pulse firing (modulating optional)
| Parameter | Published value / configuration |
|---|---|
| Applications | Radiant tube heating in industrial furnaces |
| Specific Gravity | 0.6 |
| Recuperator Type | Internal recuperator |
| Burner Configuration | Single‑ended |
| Pipe Connection Type | BSP and NPT thread standards |
| Outer Tube | Ceramic or Metallic |
| Models | SER450, SER600, SER800 |
| Burner Type | Nozzle-mix burner with integrated recuperator |
| Minimum Blower Pressure | ≥ 15 in. w.c. (37 mbar) recommended |
| Maximum Furnace Temperature | 1850 deg F (1010 deg C) |
| Main Gas Safety | Dual shut‑off valves per NFPA |
| Ignition Type | Direct Spark Ignition |
| Flame Sensor | UV Scanner |
| Flame Monitoring | UV Scanner (required for ceramic tubes) |
| Heating Value | 1004 Btu/ft³ (40 MJ/m³) |
| Heating Type | Indirect heating |
| Fuel Type | Natural Gas (CH₄ ≥ 90%) |
| Flame Length | Based on tube length and model |
| Exhaust Housing | Insulated for cooler working environment |
| Diameter | 4.5 in, 6 in, 8 in |
| Control Type | High/Low pulse firing (modulating optional) |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 10003161 | GSKT,SQ,SER,3 1/4,ADPT,OUTR,3 1/2 | Request quotation |
| 10003162 | GSKT,SQ,SER,3 1/4,ADPT,OUTR,4 1/2 | Request quotation |
| 10003163 | GSKT,SQ,SER,3 1/4,ADPT,INR,2 1/2 | Request quotation |
| 10003164 | KIT,ADPT,SER,3 1/4,OUTR | Request quotation |
| 10003165 | KIT,ADPT,SER,3 1/4,INR | Request quotation |
| 10009701 | GSKT,INR TB,PTB035,SIC,7.5 " | Request quotation |
| 10011070-1 | CMBSTR,SER,VRSN 3,4.5 IN.,22MM BORE | Request quotation |
| 10011071-1 | NZL,SER450,1 HOLE | Request quotation |
| 10011071-2 | NZL,SER450,2 HOLE | Request quotation |
| 10011073-1 | TB,GAS,SER450,440MM LG | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Single Ended Radiant Tube Burner (SER) Product Image · Manufacturer ownership retained; republication licence not independently confirmed
Single Ended Radiant Tube Burner (SER) Product Image 4 · Manufacturer ownership retained; republication licence not independently confirmed
Single Ended Radiant Tube Burner (SER) Product Image 3 · Manufacturer ownership retained; republication licence not independently confirmed
Single Ended Radiant Tube Burner (SER) Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed
Single Ended Radiant Tube Burner (SER) Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.
Tell us about your facility and what you need to achieve.