Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Self-Recuperative and Radiant Tube Burners

Single Ended Radiant Tube Burner (SER)

SER V5 combines burner and recuperator concentrically within a radiant tube.

SER V5 combines burner and recuperator concentrically within a radiant tube. Counterflow exhaust recovery and a dual-finned combustor preheat combustion air, while insulation limits heat escaping near the mounting. Horizontal or vertical installation is described; fuel and NOx reductions are manufacturer comparisons against specified earlier burner arrangements.

Features & Benefits

Specific Gravity
0.6
Recuperator Type
Internal recuperator
Pipe Connection Type
BSP and NPT thread standards
Outer Tube
Ceramic or Metallic
Minimum Blower Pressure
≥ 15 in. w.c. (37 mbar) recommended
Maximum Furnace Temperature
1850 deg F (1010 deg C)
Main Gas Safety
Dual shut‑off valves per NFPA
Ignition Type
Direct Spark Ignition
Heating Value
1004 Btu/ft³ (40 MJ/m³)
Heating Type
Indirect heating
Fuel Type
Natural Gas (CH₄ ≥ 90%)
Flame Sensor
UV Scanner
Flame Monitoring
UV Scanner (required for ceramic tubes)
Flame Length
Based on tube length and model
Exhaust Housing
Insulated for cooler working environment
Diameter
4.5 in, 6 in, 8 in
Control Type
High/Low pulse firing (modulating optional)
Burner Type
Nozzle-mix burner with integrated recuperator
Burner Configuration
Single‑ended
  • Integrated recovery avoids external recuperators and insulated air piping.
  • Insulated mounting components reduce heat near the working area.

Applications

  • Single-ended radiant-tube furnace heating

Detailed capabilities

Counterflow recovery inside the radiant tube

SER V5 places burner and recuperator coaxially inside the tube. Exhaust heat travels back toward the incoming combustion air through a counterflow path, producing preheat without external recovery ductwork. A dual-finned combustor expands the transfer area. The insulated mounting flange and exhaust housing retain useful heat and lower the surrounding working temperature compared with an uninsulated heat-loss path.

Manufacturer reference ↗

Efficiency comparisons and mounting

Honeywell reports fuel savings against sealed ambient-air burners and still larger savings against atmospheric equipment, together with a NOx reduction relative to conventional recuperative burners. These are different comparison baselines and should not be merged into a universal savings percentage. The compact assembly supports vertical or horizontal installation in suitable furnaces, with heat-flux uniformity intended to support even processing and radiant-tube life.

Manufacturer reference ↗

Features and benefits

  • Integrated recovery avoids external recuperators and insulated air piping.
  • Insulated mounting components reduce heat near the working area.

Manufacturer reference ↗

Published application context

  • Single-ended radiant-tube furnace heating

Manufacturer reference ↗

Specifications

Applications & Compatibility

Applications
Radiant tube heating in industrial furnaces

Measurement, Media & Physical Properties

Specific Gravity
0.6

Combustion, Fuel & Mixing Sub‑Systems

Recuperator Type
Internal recuperator
Burner Configuration
Single‑ended

Connections & Interfaces

Pipe Connection Type
BSP and NPT thread standards

Mechanical Design & Hardware Details

Outer Tube
Ceramic or Metallic

Overview

Models
SER450, SER600, SER800
Burner Type
Nozzle-mix burner with integrated recuperator

Pressure Specifications

Minimum Blower Pressure
≥ 15 in. w.c. (37 mbar) recommended

Maximum/Minimum Temperature Limits

Maximum Furnace Temperature
1850 deg F (1010 deg C)

Safety, Protection & Reliability

Main Gas Safety
Dual shut‑off valves per NFPA

Ignition, Flame & Supervision Specifications

Ignition Type
Direct Spark Ignition
Flame Sensor
UV Scanner
Flame Monitoring
UV Scanner (required for ceramic tubes)

Thermal, Flow & Process Characteristics

Heating Value
1004 Btu/ft³ (40 MJ/m³)
Heating Type
Indirect heating

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas (CH₄ ≥ 90%)

Burner/Flame‑Related Lengths

Flame Length
Based on tube length and model

Mechanical Design & Adjustment Characteristics

Exhaust Housing
Insulated for cooler working environment

Dimensions & Size Specifications

Diameter
4.5 in, 6 in, 8 in

Control, Logic & Functional Behavior

Control Type
High/Low pulse firing (modulating optional)
Single Ended Radiant Tube Burner (SER) — manufacturer page values
ParameterPublished value / configuration
ApplicationsRadiant tube heating in industrial furnaces
Specific Gravity0.6
Recuperator TypeInternal recuperator
Burner ConfigurationSingle‑ended
Pipe Connection TypeBSP and NPT thread standards
Outer TubeCeramic or Metallic
ModelsSER450, SER600, SER800
Burner TypeNozzle-mix burner with integrated recuperator
Minimum Blower Pressure≥ 15 in. w.c. (37 mbar) recommended
Maximum Furnace Temperature1850 deg F (1010 deg C)
Main Gas SafetyDual shut‑off valves per NFPA
Ignition TypeDirect Spark Ignition
Flame SensorUV Scanner
Flame MonitoringUV Scanner (required for ceramic tubes)
Heating Value1004 Btu/ft³ (40 MJ/m³)
Heating TypeIndirect heating
Fuel TypeNatural Gas (CH₄ ≥ 90%)
Flame LengthBased on tube length and model
Exhaust HousingInsulated for cooler working environment
Diameter4.5 in, 6 in, 8 in
Control TypeHigh/Low pulse firing (modulating optional)

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
10003161GSKT,SQ,SER,3 1/4,ADPT,OUTR,3 1/2Request quotation
10003162GSKT,SQ,SER,3 1/4,ADPT,OUTR,4 1/2Request quotation
10003163GSKT,SQ,SER,3 1/4,ADPT,INR,2 1/2Request quotation
10003164KIT,ADPT,SER,3 1/4,OUTRRequest quotation
10003165KIT,ADPT,SER,3 1/4,INRRequest quotation
10009701GSKT,INR TB,PTB035,SIC,7.5 "Request quotation
10011070-1CMBSTR,SER,VRSN 3,4.5 IN.,22MM BORERequest quotation
10011071-1NZL,SER450,1 HOLERequest quotation
10011071-2NZL,SER450,2 HOLERequest quotation
10011073-1TB,GAS,SER450,440MM LGRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/self-recuperative-and-radiant-tube-burners/single-ended-radiant-tube-burner-ser

Last source check: 2026-11-02

Single Ended Radiant Tube Burner (SER) Product Image · Manufacturer ownership retained; republication licence not independently confirmed

Single Ended Radiant Tube Burner (SER) Product Image 4 · Manufacturer ownership retained; republication licence not independently confirmed

Single Ended Radiant Tube Burner (SER) Product Image 3 · Manufacturer ownership retained; republication licence not independently confirmed

Single Ended Radiant Tube Burner (SER) Product Image 2 · Manufacturer ownership retained; republication licence not independently confirmed

Single Ended Radiant Tube Burner (SER) Product Image 1 · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry