Pilot Burners
Pilot burner ZKIH
ZKIH provides forced-air pilot ignition for gas burners supervised by the named automatic-control families.
ZKIH provides forced-air pilot ignition for gas burners supervised by the named automatic-control families. It covers 2–7 kW using natural gas, town gas or LPG, with threaded connections. The source preserves its paired burner-tube length notation, which should be used directly when selecting the required mechanical arrangement.
Features & Benefits
- Protective Tube Material
- Stainless Steel
- Protective Tube Length
- 150 to 900 mm (ZKIH), 180 to 930 mm (ZKIHB)
- Product Variants
- ZKIH (standard), ZKIHB (high-velocity burners)
- Maximum Protective Tube Temperature
- 500 deg C (932 deg F)
- Maximum Flame Tube Temperature
- <1000°C (1832°F), <900°C (1652°F) for λ<1
- Material
- Aluminium splash‑proof connection housing
- Installation Notes
- Insulate burner; prevent thermal overload; air purge recommended; pilot tip must not contact main flame
- Ignition Type
- Direct spark ignition
- Gas Type
- Natural Gas, LPG, Town Gas, Coke Oven Gas | On-Delivery - Factory‑set for natural gas (convertible)
- Gas Inlet Pressure
- Air: 5 to 40 mbar (2 to 16 in WC)|Gas: 5 to 50 mbar (2 to 20 in WC)
- Flame Tube Material
- Heat‑resistant steel
- Flame Monitoring
- Flame rod (ionization)
- Flame Length
- Approximately 25 cm (9.8 in)
- Cooling Requirements
- 3 mm cooling air gap required around protective tube
- Conversion Capability
- Easily convertible to LPG or town gas
- Connection Type
- Rp Internal Thread (R)
- Capacity
- 2 to 7 kW (NG max 5 kW)
- Approvals
- EN 746‑2, Machinery Directive 2006/42/EC, EAC certified
- Length of burner tube
- 150/100 to 1000/100 mm
Applications
- Forced-air gas-pilot ignition
Applications & Compatibility
- Applications
- Ignition of main burners in industrial furnaces; can operate independently (2-7 kW NG max 5 kW)
Material Specifications
- Protective Tube Material
- Stainless Steel
- Material
- Aluminium splash‑proof connection housing
- Flame Tube Material
- Heat‑resistant steel
Dimensions & Length Specifications
- Protective Tube Length
- 150 to 900 mm (ZKIH), 180 to 930 mm (ZKIHB)
Product Overview & Classification
- Product Variants
- ZKIH (standard), ZKIHB (high-velocity burners)
Fluid/Media/Component Temperatures
- Maximum Protective Tube Temperature
- 500 deg C (932 deg F)
Combustion/Furnace/Chamber Temperatures
- Maximum Flame Tube Temperature
- <1000°C (1832°F), <900°C (1652°F) for λ<1
Installation & Mounting Specifications
- Installation Notes
- Insulate burner; prevent thermal overload; air purge recommended; pilot tip must not contact main flame
Ignition, Flame & Supervision Specifications
- Ignition Type
- Direct spark ignition
- Flame Monitoring
- Flame rod (ionization)
- Cooling Requirements
- 3 mm cooling air gap required around protective tube
Fuel, Gas & Media Specifications
- Gas Type
- Natural Gas, LPG, Town Gas, Coke Oven Gas; On-Delivery - Factory‑set for natural gas (convertible)
Pressure Specifications
- Gas Inlet Pressure
- Air: 5 to 40 mbar (2 to 16 in WC); Gas: 5 to 50 mbar (2 to 20 in WC)
Burner/Flame‑Related Lengths
- Flame Length
- Approximately 25 cm (9.8 in)
Processing & Performance Metrics
- Conversion Capability
- Easily convertible to LPG or town gas
Connections & Interfaces
- Connection Type
- Rp Internal Thread (R)
Performance Specifications
- Capacity
- 2 to 7 kW (NG max 5 kW)
Standards & Certifications
- Approvals
- EN 746‑2, Machinery Directive 2006/42/EC, EAC certified
Technical Specifications
- Length of burner tube
- 150/100 to 1000/100 mm
| Parameter | Published value / configuration |
|---|---|
| Applications | Ignition of main burners in industrial furnaces; can operate independently (2-7 kW NG max 5 kW) |
| Protective Tube Material | Stainless Steel |
| Material | Aluminium splash‑proof connection housing |
| Flame Tube Material | Heat‑resistant steel |
| Protective Tube Length | 150 to 900 mm (ZKIH), 180 to 930 mm (ZKIHB) |
| Product Variants | ZKIH (standard), ZKIHB (high-velocity burners) |
| Maximum Protective Tube Temperature | 500 deg C (932 deg F) |
| Maximum Flame Tube Temperature | <1000°C (1832°F), <900°C (1652°F) for λ<1 |
| Installation Notes | Insulate burner; prevent thermal overload; air purge recommended; pilot tip must not contact main flame |
| Ignition Type | Direct spark ignition |
| Flame Monitoring | Flame rod (ionization) |
| Cooling Requirements | 3 mm cooling air gap required around protective tube |
| Gas Type | Natural Gas, LPG, Town Gas, Coke Oven Gas; On-Delivery - Factory‑set for natural gas (convertible) |
| Gas Inlet Pressure | Air: 5 to 40 mbar (2 to 16 in WC); Gas: 5 to 50 mbar (2 to 20 in WC) |
| Flame Length | Approximately 25 cm (9.8 in) |
| Conversion Capability | Easily convertible to LPG or town gas |
| Connection Type | Rp Internal Thread (R) |
| Capacity | 2 to 7 kW (NG max 5 kW) |
| Approvals | EN 746‑2, Machinery Directive 2006/42/EC, EAC certified |
| Length of burner tube | 150/100 to 1000/100 mm |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
10 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 74974114 | burner tube assy. ZKIH 400/100 | Request quotation |
| KS84099637 | ZKIH 300/0RZ,PILT BRNR,SPL VRSN FA. CERT | Request quotation |
| KS84199411 | ZKIHB 180/100R | Request quotation |
| KS84199420 | ZKIH 200/100R | Request quotation |
| KS84199430 | ZKIH 300/100R | Request quotation |
| KS84214010 | ZKIH 150/100R | Request quotation |
| KS84214040 | ZKIH 400/100R | Request quotation |
| KS84214050 | BRNR,ZKIH T500/100R PILT USED W/ADPT SET | Request quotation |
| KS84214060 | BRNR,ZKIH 600/100R PILT | Request quotation |
| KS84214070 | BRNR,ZKIH 700/100R PILT | Request quotation |
Manufacturer sources
Last source check: 2026-11-02
Pilot Burner · Manufacturer ownership retained; republication licence not independently confirmed
ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.
Your next project. A clear starting point.