Pilot burner ZKIH

ZKIH provides forced-air pilot ignition for gas burners supervised by the named automatic-control families.

ZKIH provides forced-air pilot ignition for gas burners supervised by the named automatic-control families. It covers 2–7 kW using natural gas, town gas or LPG, with threaded connections. The source preserves its paired burner-tube length notation, which should be used directly when selecting the required mechanical arrangement.

Features & Benefits

Protective Tube Material
Stainless Steel
Protective Tube Length
150 to 900 mm (ZKIH), 180 to 930 mm (ZKIHB)
Product Variants
ZKIH (standard), ZKIHB (high-velocity burners)
Maximum Protective Tube Temperature
500 deg C (932 deg F)
Maximum Flame Tube Temperature
<1000°C (1832°F), <900°C (1652°F) for λ<1
Material
Aluminium splash‑proof connection housing
Installation Notes
Insulate burner; prevent thermal overload; air purge recommended; pilot tip must not contact main flame
Ignition Type
Direct spark ignition
Gas Type
Natural Gas, LPG, Town Gas, Coke Oven Gas | On-Delivery - Factory‑set for natural gas (convertible)
Gas Inlet Pressure
Air: 5 to 40 mbar (2 to 16 in WC)|Gas: 5 to 50 mbar (2 to 20 in WC)
Flame Tube Material
Heat‑resistant steel
Flame Monitoring
Flame rod (ionization)
Flame Length
Approximately 25 cm (9.8 in)
Cooling Requirements
3 mm cooling air gap required around protective tube
Conversion Capability
Easily convertible to LPG or town gas
Connection Type
Rp Internal Thread (R)
Capacity
2 to 7 kW (NG max 5 kW)
Approvals
EN 746‑2, Machinery Directive 2006/42/EC, EAC certified
Length of burner tube
150/100 to 1000/100 mm

Applications

  • Forced-air gas-pilot ignition

Specifications

Applications & Compatibility

Applications
Ignition of main burners in industrial furnaces; can operate independently (2-7 kW NG max 5 kW)

Material Specifications

Protective Tube Material
Stainless Steel
Material
Aluminium splash‑proof connection housing
Flame Tube Material
Heat‑resistant steel

Dimensions & Length Specifications

Protective Tube Length
150 to 900 mm (ZKIH), 180 to 930 mm (ZKIHB)

Product Overview & Classification

Product Variants
ZKIH (standard), ZKIHB (high-velocity burners)

Fluid/Media/Component Temperatures

Maximum Protective Tube Temperature
500 deg C (932 deg F)

Combustion/Furnace/Chamber Temperatures

Maximum Flame Tube Temperature
<1000°C (1832°F), <900°C (1652°F) for λ<1

Installation & Mounting Specifications

Installation Notes
Insulate burner; prevent thermal overload; air purge recommended; pilot tip must not contact main flame

Ignition, Flame & Supervision Specifications

Ignition Type
Direct spark ignition
Flame Monitoring
Flame rod (ionization)
Cooling Requirements
3 mm cooling air gap required around protective tube

Fuel, Gas & Media Specifications

Gas Type
Natural Gas, LPG, Town Gas, Coke Oven Gas; On-Delivery - Factory‑set for natural gas (convertible)

Pressure Specifications

Gas Inlet Pressure
Air: 5 to 40 mbar (2 to 16 in WC); Gas: 5 to 50 mbar (2 to 20 in WC)

Burner/Flame‑Related Lengths

Flame Length
Approximately 25 cm (9.8 in)

Processing & Performance Metrics

Conversion Capability
Easily convertible to LPG or town gas

Connections & Interfaces

Connection Type
Rp Internal Thread (R)

Performance Specifications

Capacity
2 to 7 kW (NG max 5 kW)

Standards & Certifications

Approvals
EN 746‑2, Machinery Directive 2006/42/EC, EAC certified

Technical Specifications

Length of burner tube
150/100 to 1000/100 mm
Pilot burner ZKIH — manufacturer page values
ParameterPublished value / configuration
ApplicationsIgnition of main burners in industrial furnaces; can operate independently (2-7 kW NG max 5 kW)
Protective Tube MaterialStainless Steel
MaterialAluminium splash‑proof connection housing
Flame Tube MaterialHeat‑resistant steel
Protective Tube Length150 to 900 mm (ZKIH), 180 to 930 mm (ZKIHB)
Product VariantsZKIH (standard), ZKIHB (high-velocity burners)
Maximum Protective Tube Temperature500 deg C (932 deg F)
Maximum Flame Tube Temperature<1000°C (1832°F), <900°C (1652°F) for λ<1
Installation NotesInsulate burner; prevent thermal overload; air purge recommended; pilot tip must not contact main flame
Ignition TypeDirect spark ignition
Flame MonitoringFlame rod (ionization)
Cooling Requirements3 mm cooling air gap required around protective tube
Gas TypeNatural Gas, LPG, Town Gas, Coke Oven Gas; On-Delivery - Factory‑set for natural gas (convertible)
Gas Inlet PressureAir: 5 to 40 mbar (2 to 16 in WC); Gas: 5 to 50 mbar (2 to 20 in WC)
Flame LengthApproximately 25 cm (9.8 in)
Conversion CapabilityEasily convertible to LPG or town gas
Connection TypeRp Internal Thread (R)
Capacity2 to 7 kW (NG max 5 kW)
ApprovalsEN 746‑2, Machinery Directive 2006/42/EC, EAC certified
Length of burner tube150/100 to 1000/100 mm

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

10 parts

Part NumberDescriptionEnquiry
74974114burner tube assy. ZKIH 400/100Request quotation
KS84099637ZKIH 300/0RZ,PILT BRNR,SPL VRSN FA. CERTRequest quotation
KS84199411ZKIHB 180/100RRequest quotation
KS84199420ZKIH 200/100RRequest quotation
KS84199430ZKIH 300/100RRequest quotation
KS84214010ZKIH 150/100RRequest quotation
KS84214040ZKIH 400/100RRequest quotation
KS84214050BRNR,ZKIH T500/100R PILT USED W/ADPT SETRequest quotation
KS84214060BRNR,ZKIH 600/100R PILTRequest quotation
KS84214070BRNR,ZKIH 700/100R PILTRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/pilot-burners/pilot-burner-zkih

Last source check: 2026-11-02

Pilot Burner · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry