Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Pilot Burners

OXY-PILOT®

OXY-PILOT ignites MAXON OXY-THERM LE burners with a published maximum input of 25,000 Btu/hr.

OXY-PILOT ignites MAXON OXY-THERM LE burners with a published maximum input of 25,000 Btu/hr. It permits automated burner operation without a separate combustion-air supply or retractable igniter. The page describes this specific pairing rather than declaring compatibility with every oxy-fuel burner or controller.

Features & Benefits

Capacity
25,000 BTU/hr
Ignition Transformer Specs
6000 V full-wave spark ignition transformer
Installation Interface
Threads directly into burner housing (OXY‑THERM® LE) or via bolt‑on adapter (Standard OXY‑THERM®)
Electrical Connections
0.25 in female spade for ignition transformer
Flow Capacity Range
Natural Gas - 25 SCFH at 25 in. wc, Propane - 10 SCFH at 38 in. wc, Oxygen - 35 SCFH at 5 in. wc
Ignition Connector
0.25 in female spade connector
Insulator Block
Must not be removed; prevents stray voltages
Inlet Sizes
Oxygen - 1/2 in NPT, Natural Gas - 3/16 in O.D. tube (removable to 1/8 in NPT)
Fuel Type
Natural Gas, Propane, Oxygen
  • Automated pilot operation avoids separate combustion-air and retracting-igniter equipment.

Applications

  • Pilot ignition of OXY-THERM LE burners

Specifications

Performance Specifications

Capacity
25,000 BTU/hr

Ignition, Flame & Supervision Specifications

Ignition Transformer Specs
6000 V full-wave spark ignition transformer

Installation & Mounting Specifications

Installation Interface
Threads directly into burner housing (OXY‑THERM® LE) or via bolt‑on adapter (Standard OXY‑THERM®)

Connections & Interfaces

Electrical Connections
0.25 in female spade for ignition transformer
Ignition Connector
0.25 in female spade connector

Processing & Performance Metrics

Flow Capacity Range
Natural Gas - 25 SCFH at 25 in. wc, Propane - 10 SCFH at 38 in. wc, Oxygen - 35 SCFH at 5 in. wc

Mechanical Design & Adjustment Characteristics

Insulator Block
Must not be removed; prevents stray voltages

Applications & Compatibility

Applications
Ignition pilot for OXY-THERM® LE and Standard OXY-THERM® burners

Dimensions & Size Specifications

Inlet Sizes
Oxygen - 1/2 in NPT, Natural Gas - 3/16 in O.D. tube (removable to 1/8 in NPT)

Fuel, Gas & Media Specifications

Fuel Type
Natural Gas, Propane, Oxygen
OXY-PILOT® — manufacturer page values
ParameterPublished value / configuration
Capacity25,000 BTU/hr
Ignition Transformer Specs6000 V full-wave spark ignition transformer
Installation InterfaceThreads directly into burner housing (OXY‑THERM® LE) or via bolt‑on adapter (Standard OXY‑THERM®)
Electrical Connections0.25 in female spade for ignition transformer
Ignition Connector0.25 in female spade connector
Flow Capacity RangeNatural Gas - 25 SCFH at 25 in. wc, Propane - 10 SCFH at 38 in. wc, Oxygen - 35 SCFH at 5 in. wc
Insulator BlockMust not be removed; prevents stray voltages
ApplicationsIgnition pilot for OXY-THERM® LE and Standard OXY-THERM® burners
Inlet SizesOxygen - 1/2 in NPT, Natural Gas - 3/16 in O.D. tube (removable to 1/8 in NPT)
Fuel TypeNatural Gas, Propane, Oxygen

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

2 parts

Part NumberDescriptionEnquiry
1045408OXY PILT ASYRequest quotation
1052871OXY PILT W/UV ASYRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/pilot-burners/oxy-pilot

Last source check: 2026-11-02

OXY-PILOT® Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.

CallSend enquiry