Pilot Burners
OXY-PILOT®
OXY-PILOT ignites MAXON OXY-THERM LE burners with a published maximum input of 25,000 Btu/hr.
OXY-PILOT ignites MAXON OXY-THERM LE burners with a published maximum input of 25,000 Btu/hr. It permits automated burner operation without a separate combustion-air supply or retractable igniter. The page describes this specific pairing rather than declaring compatibility with every oxy-fuel burner or controller.
Features & Benefits
- Capacity
- 25,000 BTU/hr
- Ignition Transformer Specs
- 6000 V full-wave spark ignition transformer
- Installation Interface
- Threads directly into burner housing (OXY‑THERM® LE) or via bolt‑on adapter (Standard OXY‑THERM®)
- Electrical Connections
- 0.25 in female spade for ignition transformer
- Flow Capacity Range
- Natural Gas - 25 SCFH at 25 in. wc, Propane - 10 SCFH at 38 in. wc, Oxygen - 35 SCFH at 5 in. wc
- Ignition Connector
- 0.25 in female spade connector
- Insulator Block
- Must not be removed; prevents stray voltages
- Inlet Sizes
- Oxygen - 1/2 in NPT, Natural Gas - 3/16 in O.D. tube (removable to 1/8 in NPT)
- Fuel Type
- Natural Gas, Propane, Oxygen
- Automated pilot operation avoids separate combustion-air and retracting-igniter equipment.
Applications
- Pilot ignition of OXY-THERM LE burners
Performance Specifications
- Capacity
- 25,000 BTU/hr
Ignition, Flame & Supervision Specifications
- Ignition Transformer Specs
- 6000 V full-wave spark ignition transformer
Installation & Mounting Specifications
- Installation Interface
- Threads directly into burner housing (OXY‑THERM® LE) or via bolt‑on adapter (Standard OXY‑THERM®)
Connections & Interfaces
- Electrical Connections
- 0.25 in female spade for ignition transformer
- Ignition Connector
- 0.25 in female spade connector
Processing & Performance Metrics
- Flow Capacity Range
- Natural Gas - 25 SCFH at 25 in. wc, Propane - 10 SCFH at 38 in. wc, Oxygen - 35 SCFH at 5 in. wc
Mechanical Design & Adjustment Characteristics
- Insulator Block
- Must not be removed; prevents stray voltages
Applications & Compatibility
- Applications
- Ignition pilot for OXY-THERM® LE and Standard OXY-THERM® burners
Dimensions & Size Specifications
- Inlet Sizes
- Oxygen - 1/2 in NPT, Natural Gas - 3/16 in O.D. tube (removable to 1/8 in NPT)
Fuel, Gas & Media Specifications
- Fuel Type
- Natural Gas, Propane, Oxygen
| Parameter | Published value / configuration |
|---|---|
| Capacity | 25,000 BTU/hr |
| Ignition Transformer Specs | 6000 V full-wave spark ignition transformer |
| Installation Interface | Threads directly into burner housing (OXY‑THERM® LE) or via bolt‑on adapter (Standard OXY‑THERM®) |
| Electrical Connections | 0.25 in female spade for ignition transformer |
| Ignition Connector | 0.25 in female spade connector |
| Flow Capacity Range | Natural Gas - 25 SCFH at 25 in. wc, Propane - 10 SCFH at 38 in. wc, Oxygen - 35 SCFH at 5 in. wc |
| Insulator Block | Must not be removed; prevents stray voltages |
| Applications | Ignition pilot for OXY-THERM® LE and Standard OXY-THERM® burners |
| Inlet Sizes | Oxygen - 1/2 in NPT, Natural Gas - 3/16 in O.D. tube (removable to 1/8 in NPT) |
| Fuel Type | Natural Gas, Propane, Oxygen |
Values retain manufacturer model qualifications. Review Honeywell specifications ↗
Part Number
Published part numbers
2 parts
| Part Number | Description | Enquiry |
|---|---|---|
| 1045408 | OXY PILT ASY | Request quotation |
| 1052871 | OXY PILT W/UV ASY | Request quotation |
Manufacturer sources
Last source check: 2026-11-02