Fire & Life Safety · Building Systems · Industrial Automation [email protected] +880 1347 561 256
Honeywell Process Measurement & Control

Pilot Burners

LVDT-HC Pilot Burner

LVDT/HC pilots fit the named MAXON duct-burner families using fixed orifices that avoid field air/fuel adjustment.

LVDT/HC pilots fit the named MAXON duct-burner families using fixed orifices that avoid field air/fuel adjustment. Stainless construction addresses hot, humid or contaminated streams, and components can be serviced from outside the duct. A ball valve isolates the scanner, while tube-length and fuel options match the installation.

Features & Benefits

Maintenance Interval
Located for easy service access
Installation Method
Integrated in slide-in mounting plug for HC burner
Airflow Interaction
Ignites gas inside mixing plates using primary combustion air
Product Category
Ignition/stabilization pilot burner
Mounting Options
Integrated on stainless‑steel mounting plug of HC AIRFLO® burner
Ignition Type
Ignition via integrated pilot flame system
Safety Role
Stable ignition and cross-ignition along burner length
Used With
HC AIRFLO® Duct Burners
Functions
Provides ignition flame and downstream pressure test point
  • Outside-duct access simplifies component service.
  • Fixed orifices avoid field air/fuel adjustment.

Applications

  • Pilot ignition for AIRFLO LV/HC, DELTA-TE and COMBUSTIFUME burners
  • Thermal incinerators and supplemental firing

Detailed capabilities

Fixed-orifice pilot and external access

LVDT/HC uses fixed orifices to establish fuel and air flow without a field ratio adjustment. The pilot penetrates the process stream to the main burner's end plate, while ignition parts remain accessible from outside. A stainless ball valve can isolate the scanner. Stainless construction, several tube lengths and the listed gas choices adapt the pilot to hot or contaminated process-air duties.

Manufacturer reference ↗

Features and benefits

  • Outside-duct access simplifies component service.
  • Fixed orifices avoid field air/fuel adjustment.

Manufacturer reference ↗

Published application context

  • Pilot ignition for AIRFLO LV/HC, DELTA-TE and COMBUSTIFUME burners
  • Thermal incinerators and supplemental firing

Manufacturer reference ↗

Specifications

Electrical Specifications

Maintenance Interval
Located for easy service access

Installation & Mounting Specifications

Installation Method
Integrated in slide-in mounting plug for HC burner
Mounting Options
Integrated on stainless‑steel mounting plug of HC AIRFLO® burner

Air & Combustion Air Specifications

Airflow Interaction
Ignites gas inside mixing plates using primary combustion air

Overview

Product Category
Ignition/stabilization pilot burner

Ignition, Flame & Supervision Specifications

Ignition Type
Ignition via integrated pilot flame system

Applications & Compatibility

Applications
Ignition and flame stabilization of HC AIRFLO® duct burners
Used With
HC AIRFLO® Duct Burners

Safety, Protection & Reliability

Safety Role
Stable ignition and cross-ignition along burner length

Control, Logic & Functional Behavior

Functions
Provides ignition flame and downstream pressure test point
LVDT-HC Pilot Burner — manufacturer page values
ParameterPublished value / configuration
Maintenance IntervalLocated for easy service access
Installation MethodIntegrated in slide-in mounting plug for HC burner
Mounting OptionsIntegrated on stainless‑steel mounting plug of HC AIRFLO® burner
Airflow InteractionIgnites gas inside mixing plates using primary combustion air
Product CategoryIgnition/stabilization pilot burner
Ignition TypeIgnition via integrated pilot flame system
ApplicationsIgnition and flame stabilization of HC AIRFLO® duct burners
Used WithHC AIRFLO® Duct Burners
Safety RoleStable ignition and cross-ignition along burner length
FunctionsProvides ignition flame and downstream pressure test point

Values retain manufacturer model qualifications. Review Honeywell specifications ↗

Part Number

Published part numbers

6 parts

Part NumberDescriptionEnquiry
300562_VLVDT-450 SPARK IGNITORRequest quotation
300564_VLVDT-600 SPARK IGNITORRequest quotation
300566_VLVDT-750 SPARK IGNITORRequest quotation
300568_VLVDT-900 SPARK IGNITORRequest quotation
311100_VGASKET LVDT PILOTRequest quotation
311760_VLVDT-HC SS PLT GAS ORIF.30mbarRequest quotation
Manufacturer sources

https://process.honeywell.com/us/en/products/thermal-solutions/burners-and-heat-exchangers/pilot-burners/lvdt-hc-pilot-burner

Last source check: 2026-11-02

LVDT-HC Pilot Burner Product Image · Manufacturer ownership retained; republication licence not independently confirmed

ABID Automation LTD maintains this independent product reference. Honeywell owns its product names and trademarks. Current manufacturer documentation governs specification, availability and certification.

Your next project. A clear starting point.

Tell us about your facility and what you need to achieve.